Brand:

Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000 psi, SAE-6

Description

HDA 4775-A-3000-000 is the 3000 psi transmitter of the HDA 4700 line and the best-known size for industrial and mobile hydraulics, where system pressure is commonly 207 bar. Its SAE-6 male port, 4 to 20 mA output and DIN 43650 plug make it a drop-in replacement for many older units. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why 3000 psi matters

Most hydraulic presses, injection moulding units and mobile machines operate between 2000 and 3000 psi, and relief valves typically open slightly above. A 3000 psi span with 7250 psi overload gives a comfortable reserve when the relief opens or when line shock appears. At full scale the 0.25 percent accuracy equals 7.5 psi. That tolerance is acceptable for hydraulic control but should not be mistaken for laboratory accuracy, so HDA 4775-A-3000-000 is paired with calibration checks in critical systems.

The reserve figures deserve attention when the system is cycled hard. The transmitter is rated for more than 10 million cycles over the full 0 to 100 percent range; in a press that makes one cycle every 10 seconds, that equals more than three years of continuous service even at the limit of the specified life. Many applications cycle over only part of the range, which extends the useful life further.

Features

  • Overload 7250 psi and burst 14500 psi.
  • Rise time 1 ms or less for fast control loops.
  • Stainless steel cell and connection, FKM seal.
  • Pins: 1 signal plus, 2 signal minus, 3 not connected.
  • Compensated temperature -13 to 185 degF.
  • Operating life above 10 million cycles.

Technical data of HDA 4775-A-3000-000

Parameter Value
Model code HDA 4775-A-3000-000
Material number (catalog) 907188
Measuring range 0 to 3000 psi
Overload pressure 7250 psi
Burst pressure 14500 psi
Process connection 9/16-18 UNF 2A male (SAE 6)
Tightening torque 15 lb-ft (20 N·m)
Output signal 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, ripple 5 percent or less
Current consumption 25 mA or less
Accuracy (terminal based) 0.25 percent FS typical and maximum at max. setting
Accuracy (best-fit line) 0.15 percent FS typical, 0.25 percent maximum
Temperature coefficient 0.008 percent FS per degC typical, 0.015 maximum (zero and span)
Non-linearity / hysteresis 0.3 / 0.1 percent FS maximum
Repeatability 0.05 percent FS
Rise time 1 ms or less
Long-term drift 0.1 percent FS per year typical
Electrical connection EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied
Pins 1 signal +, 2 signal -, 3 not connected, earth = housing
Protection class IP 67 with the mating connector fitted
Wetted parts Stainless steel connection; FKM seal
Compensated temperature -13 to 185 degF
Fluid temperature -13 to 212 degF
Storage temperature -40 to 212 degF
Vibration 20 g, 10 to 500 Hz
Life expectancy more than 10 million cycles, 0 to 100 percent FS
Weight about 145 g

Applications

Accumulator pressure on drilling-rig hydraulic units, press control, machine-tool clamping and pump-regulation feedback are typical. In Oman and the GCC the device also appears on workshop test stands for valve and cylinder certification. In non-classified areas the transmitter connects directly to a PLC analog card; for classified zones use an Ex d variant.

How HDA 4775-A-3000-000 differs from the other 4775 ranges

The 0750 and 1000 psi variants carry 1740 and 2900 psi of overload; this one carries 7250 psi. The 5000 psi version raises overload to 11600 psi and burst to 29000 psi. Resolution is therefore coarser by a factor of four against 0750, but the signal-to-error ratio is the same, since accuracy is a percentage of full scale. The plug, thread and wiring of HDA 4775-A-3000-000 are identical.

Selecting

If the working pressure is below 1500 psi, the 1000 or 1500 psi range gives better resolution. If the system uses intensifiers, check whether 5000 psi is needed. The mating port should be SAE-6 with an O-ring seat, so adapters from NPT or BSP need an external seal.

Installation

Use a lightly oiled O-ring, tighten to 20 N·m, fit the connector and run the loop at 8 to 30 V DC. For HDA 4775-A-3000-000 confirm 4 mA at zero, 12 mA at 1500 psi and 20 mA at 3000 psi.

Maintenance

Keep the connector seal intact; most field failures of pressure transmitters are water ingress, not cell failures. If the output sticks at 4 mA with pressure applied, check the loop supply before replacing the unit.

Spare-part planning: all HDA 4775 ranges use the same SAE-6 port, O-ring and plug. The material number 907188 identifies the 3000 psi version in the catalog. Replacing a 3000 psi unit with a 5000 psi unit works mechanically, yet the control scaling must be changed, so always match the range code before commissioning, and update the loop sheet and the DCS tag description at the same time.

What to Include in Your Hydac HDA 4775-A-3000-000 Enquiry

An accurate quotation for the Hydac HDA 4775-A-3000-000 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing pressure transmitters and reply with availability and a realistic delivery estimate.

Spares and Lifecycle Considerations

For critical service, many plants hold one Hydac HDA 4775-A-3000-000 as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical pressure transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Frequently asked questions about HDA 4775-A-3000-000

Which overload and burst does HDA 4775-A-3000-000 have? 7250 psi overload and 14500 psi burst.

Is the output voltage or current? Current: 4 to 20 mA in a two-wire loop. A voltage output would be code B in the signal position.

What torque applies? 20 N·m (15 lb-ft) on the SAE-6 male thread.

Is it suitable for 3000 psi mobile hydraulics? The range matches the typical 3000 psi system pressure, with margin to 7250 psi for peaks.

How do I order? Send an RFQ with HDA 4775-A-3000-000, quantity and the delivery site to Seven Star LLC.

Documents and quotation

The datasheet for HDA 4775-A-3000-000 is provided on this page. Send an RFQ with HDA 4775-A-3000-000, quantity and destination for availability.

Datasheets & Documents
  • PDF Datasheet Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000 psi, SAE-6 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 4775-A-3000-000 Pressure Transmitter 3000

Answers from our engineering team on installation, compatibility and integration.

01Which overload and burst does HDA 4775-A-3000-000 have?
The catalog gives 7250 psi overload pressure and 14500 psi burst pressure for this range.
02Is the output voltage or current?
Current: 4 to 20 mA in a two-wire loop. A voltage output would be code B in the signal position.
03What torque applies?
20 N·m (15 lb-ft) on the SAE-6 male thread.
04Is it suitable for 3000 psi mobile hydraulics?
The range matches the typical 3000 psi system pressure, with margin to 7250 psi for peaks.
05How do I order?
Send an RFQ with HDA 4775-A-3000-000, quantity and the delivery site to Seven Star LLC.