Brand:

Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure Transmitter 250 psi

Description

HDA 4385-A-0250-000-F1 extends the HDA 4300 ceramic-cell concept to 250 psi. It is a compact transmitter, about 150 g, with a 1/4-18 NPT male stainless connection, an FKM seal and a DIN 43650 plug. The same cell family is used by Hydac for refrigeration, air conditioning, food and pharmaceutical applications. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Where HDA 4385-A-0250-000-F1 sits in the family

The 250 psi range is the upper-middle step of the ceramic series, which stops at 500 psi. Overload of 725 psi and burst of 1000 psi are 2.9 and 4 times the range. Hysteresis is limited to 0.4 percent of full scale and non-linearity to 0.5 percent, so total error is dominated by those terms rather than by temperature.

For scaling, a controller input range of 4 to 20 mA corresponds to 0 to 250 psi, so every milliamp above 4 mA equals 15.6 psi. A measured 8 mA therefore indicates 62.5 psi. The accuracy at maximum setting of 1 percent of full scale equals 2.5 psi, which is why alarm points should be placed with that margin when they protect equipment.

Features

  • Range 0 to 250 psi.
  • Ceramic thick-film cell, stainless connection.
  • FPM seal marked F; fluid temperature up to 212 degF.
  • Plug supplied, IP 65.
  • 25 mA or less; supply 8 to 30 V DC.
  • Life expectancy above 10 million cycles.

Technical data for HDA 4385-A-0250-000-F1

Parameter Value
Model code HDA 4385-A-0250-000-F1
Material number (catalog) 908593
Measuring range 0 to 250 psi
Overload pressure 725 psi
Burst pressure 1000 psi
Sensor cell Ceramic, thick-film strain gauge
Process connection 1/4-18 NPT male, stainless steel
Tightening torque 30 lb-ft (40 N·m)
Seal FKM (code F)
Output signal 4 to 20 mA, 2-wire; load RLmax = (UB – 8 V) / 20 mA in kOhm
Supply voltage 8 to 30 V DC, ripple 5 percent or less
Current consumption 25 mA or less
Accuracy (terminal based) 0.5 percent FS typical, 1 percent maximum at max. setting
Accuracy (best-fit line) 0.25 percent FS typical, 0.5 percent maximum
Temperature coefficient 0.012 percent FS per degF typical, 0.017 maximum
Non-linearity / hysteresis 0.5 / 0.4 percent FS maximum
Repeatability / rise time 0.1 percent FS / 1 ms or less
Long-term drift 0.3 percent FS per year typical
Electrical connection EN175301-803 (DIN 43650), 3-pole + PE, mating connector supplied
Protection class IP 65 with the DIN 43650 connector
Compensated temperature -13 to 185 degF
Fluid temperature -13 to 212 degF with FPM seal
Storage temperature -40 to 212 degF
Vibration 20 g, 10 to 500 Hz
Life expectancy more than 10 million cycles
Weight about 150 g

Applications

Examples include compressed-air receivers, water-glycol circuits, chilled-water pumps and low-pressure hydraulic returns. Because the cell is ceramic, the part is insensitive to many mild chemicals, and the stainless NPT connection suits typical North American style equipment seen at some Gulf installations.

How HDA 4385-A-0250-000-F1 differs from siblings

Compared with HDA 4385-A-0050-000-F1 the range is five times larger, with overload 725 instead of 150 psi and burst 1000 instead of 250 psi. Compared with the 0500 version it has half the range and one third less overload reserve. All three share thread, plug and seal.

Selection

Match the range to the circuit: 250 psi suits systems with working pressure of about 150 psi. Check fluids for compatibility with FKM. Use the EPDM variant (code E) for refrigerants instead of HDA 4385-A-0250-000-F1.

Installation

Seal and tighten the NPT thread to 40 N·m, fit the plug with its gasket and wire pin 1 to the loop positive and pin 2 to the return. Test with a hand pump at 0 and 250 psi.

Maintenance

Check the plug gasket yearly. If the unit is exposed to freezing water, drain before winter. Replace HDA 4385-A-0250-000-F1 if a zero check shows a persistent offset beyond tolerance.

Practical notes for site teams: the ceramic cell used here is stable against long-term drift, quoted at 0.3 percent of full scale per year typical, which equals about 0.75 psi on a 250 psi range. The plug is supplied, the catalog material number is 908593 and the mating thread is 1/4 NPT. Store spares dry, because moisture inside the connector is a common cause of intermittent signals. For a fast control loop, the rise time of 1 ms or less is more than adequate, and the EMC behaviour is covered by the CE standards EN 61000-6-1 to -4, so no special shielding is needed beyond good practice. Where the transmitter feeds a chart recorder or a historian, set the scaling to 250 psi at 20 mA and confirm the zero by venting the port to atmosphere. A short test log with date and technician name rounds out the record, and the same sheet should list the loop number.

Documentation and Compliance

Industrial buyers often need more than the hardware. When you order the Hydac HDA 4385-A-0250-000-F1, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Hydac pressure transmitters items can be checked against the bill of materials quickly.

Ordering Checklist for the Hydac HDA 4385-A-0250-000-F1

Before you ask for a quotation for the Hydac HDA 4385-A-0250-000-F1, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the pressure transmitters already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.

Frequently asked questions about HDA 4385-A-0250-000-F1

What overload and burst apply to HDA 4385-A-0250-000-F1? 725 psi overload and 1000 psi burst.

Which thread is on the process side? 1/4-18 NPT male in stainless steel, tightened to 40 N·m.

Is the output 0 to 10 V? No. The A in the code is a 4 to 20 mA two-wire output. 0 to 10 V is code B.

What are the temperature limits? Compensated -13 to 185 degF; fluid -13 to 212 degF with FPM seal; storage -40 to 212 degF.

How do I enquire? Send an RFQ with HDA 4385-A-0250-000-F1, quantity and delivery site.

Documents and quotation

The datasheet for HDA 4385-A-0250-000-F1 is attached to this page. Send an RFQ with HDA 4385-A-0250-000-F1, quantity and destination for availability and lead time.

Datasheets & Documents
  • PDF Datasheet Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure Transmitter 250 psi Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac HDA 4385-A-0250-000-F1 Ceramic Pressure

Answers from our engineering team on installation, compatibility and integration.

01What overload and burst apply to HDA 4385-A-0250-000-F1?
The catalog and datasheet give 725 psi overload pressure and 1000 psi burst pressure for this range.
02Which thread is on the process side?
1/4-18 NPT male in stainless steel, tightened to 40 N·m.
03Is the output 0 to 10 V?
No. The A in the code is a 4 to 20 mA two-wire output. 0 to 10 V is code B.
04What are the temperature limits?
Compensated -13 to 185 degF; fluid -13 to 212 degF with FPM seal; storage -40 to 212 degF.
05How do I enquire?
Send an RFQ with HDA 4385-A-0250-000-F1, quantity and delivery site.