Brand:

Fluke 810 Handheld Vibration Tester

Description

Overview

The Fluke 810 vibration tester is a handheld instrument built to help maintenance technicians — not just vibration specialists — diagnose the most common mechanical problems on rotating equipment: unbalance, looseness, misalignment, and bearing failures. Rather than requiring years of vibration-analysis training to interpret a spectrum, the 810 delivers plain-text diagnosis with severity ratings directly on its screen.

Built by Fluke for field use on pumps, motors, fans, and gearboxes, the 810 fits predictive-maintenance programs where technicians need fast, actionable answers rather than raw data requiring specialist interpretation. Seven Star LLC supplies the Fluke 810 to industrial maintenance teams across Oman and the GCC.

Operating Principle

The Fluke 810 uses an accelerometer sensor to capture vibration data across a usable bandwidth of 2Hz to 20kHz, sampling at rates from 2.5kHz to 50kHz depending on the test. Built-in diagnostic software compares the captured signature against known fault patterns for the four target problem types, then reports a plain-text diagnosis, fault severity rating (slight, moderate, serious, or extreme), and repair guidance — turning what would otherwise require spectrum-analysis expertise into an actionable field readout.

Engineering Design of the Fluke 810

The 810 displays results on a 5.7-inch, 320×240 color TFT LCD with LED backlight, readable in typical plant lighting conditions. Its integrated laser tachometer measures shaft speed with accuracy of ±0.01% and ±1 digit up to 5,999.9 rpm, and ±0.05% and ±1 digit above that speed, supporting accurate order-based analysis. The lithium-ion battery provides approximately 8 hours of continuous field use with a 3-hour recharge time, and the complete unit weighs 1.9kg (4.2lb), operating across 0°C to 50°C.

Key Features

  • Diagnoses unbalance, looseness, misalignment, and bearing failures
  • Plain-text diagnosis with severity rating, no spectrum-analysis expertise required
  • Usable bandwidth 2Hz to 20kHz, sampling 2.5–50kHz
  • Integrated laser tachometer, ±0.01% accuracy up to 5,999.9 rpm
  • 5.7-inch color TFT LCD with LED backlight
  • ~8-hour lithium-ion battery life, 3-hour recharge
  • Compact 1.9kg (4.2lb) handheld form factor
  • Operating range 0°C to 50°C for field use

Industrial Applications

The Fluke 810 is used for predictive-maintenance rounds on pumps, motors, fans, and gearboxes across manufacturing, oil and gas, and power facilities in Muscat, Sohar, and Salalah, where maintenance teams need to catch developing mechanical faults before they cause unplanned downtime. Its plain-text diagnosis makes it practical for general maintenance technicians, not just dedicated vibration analysts.

Across the GCC’s industrial and process sectors, the 810 supports route-based condition monitoring programs and one-off troubleshooting alike, giving maintenance planners a fast severity assessment to prioritize repairs on rotating equipment before a bearing or coupling failure escalates into a costly breakdown.

Technical Specifications

Parameter Specification
Model Fluke 810
Fault Types Diagnosed Unbalance, looseness, misalignment, bearing failure
Frequency Bandwidth 2Hz to 20kHz
Tachometer Accuracy ±0.01% ±1 digit (≤5,999.9 rpm) / ±0.05% ±1 digit (above)
Display 5.7-inch 320×240 color TFT LCD, LED backlight
Battery Life ~8 hours, 3-hour recharge
Weight 1.9kg (4.2lb)
Operating Temperature 0°C to 50°C

Setting Up a Machine for Testing

The quality of a diagnosis depends on how well the machine is described to the instrument. Before the first measurement, the technician enters the machine setup: driver type, running speed, power, coupling arrangement and the driven equipment, such as a pump, fan or compressor. Bearing, gear or belt details can be added where known. Once saved, the setup is reused on later rounds, so readings stay comparable over time.

Taking Good Measurements

  • Mount the accelerometer on a clean, flat, rigid surface as close to the bearing as possible, avoiding thin covers and fan shrouds
  • Use the same locations on every round, marking them on the machine if needed
  • Measure with the machine at normal operating load and temperature
  • Use the laser tachometer to confirm the actual running speed rather than relying on nameplate values
  • Keep cables clear of rotating parts and secure them during the measurement

Reading the Diagnosis

For each test the Fluke 810 vibration tester reports the most likely faults with a severity level and a recommended action. Slight and moderate results usually indicate a trend to follow on the next round, while serious and extreme results call for planning a repair. The spectrum data remains available for a vibration analyst when a second opinion is needed, and results can be transferred to a PC for reporting and trending.

Building a Route-Based Programme

The instrument gives the most value when used on a regular schedule. A practical approach is to start with critical pumps, motors, fans and gearboxes, set a measurement interval based on criticality, and keep results so that developing faults are visible from one round to the next. Combining vibration results with lubrication, thermography and operating data gives planners a stronger basis for deciding when to intervene.

Care of the Instrument

Charge the battery fully before a route, store the sensor and cables in the carrying case, and inspect the sensor cable and connector regularly, since a damaged cable is a common cause of odd readings. Keep the unit within its 0°C to 50°C operating range, which in Oman and the GCC means not leaving it in vehicles or direct summer sun.

Sourcing from Seven Star LLC

Seven Star LLC supplies Fluke test and condition-monitoring instruments to maintenance teams in Muscat, Sohar, Salalah and across the GCC, with support in choosing accessories and setting up an initial measurement route.

Request a Quote for Fluke 810 Handheld Vibration Tester

Contact Seven Star LLC for a quotation and availability on the Fluke 810 handheld vibration tester and the wider Fluke test-instrument range across Oman and the GCC. Our team can help fit the right condition-monitoring tools into your maintenance program.

Browse the full Fluke range or see more Portable Test & Measurement products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Fluke 810 Handheld Vibration Tester Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

Frequently Asked Questions

What faults can the Fluke 810 detect?
It identifies and locates unbalance, looseness, misalignment and bearing failures on the first measurement, without any prior measurement history.
Which machines can it analyze?
It covers motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal and piston pumps, compressors and spindles, for motor speeds from 200 to 12,000 RPM.
How does it present diagnosis results?
Each fault is graded on a four-level severity scale (slight, moderate, serious, extreme) with repair recommendations, cited peaks and spectra shown on the color display.
What sensor does the Fluke 810 use?
It includes a 100 mV/g TEDS triaxial accelerometer that reduces measurement time by two-thirds versus single-axis sensors, plus a laser tachometer for accurate running speed.
How is measurement data stored?
Data is stored on a micro SD card plus 4 GB internal memory and managed with the included Viewer PC software for tracking and trend analysis.