Brand: Rosemount
Rosemount 01166-8005-0001 304 Heavy Duty Bracket 316 SST
Description
Rosemount 01166-8005-0001: heavy duty 316 SST bracket for the 304 manifold
Rosemount 01166-8005-0001 is described in the 304 conventional manifold spare parts table as a manifold heavy duty mounting bracket in 316 stainless steel, traditional style. Its carbon steel twin is 01166-8005-0002. The ordering table offers the same hardware as option VS (316 SST) or VC (carbon steel), both for the traditional style only, because the wafer-style 304 manifold uses a different bracket (B4).
A bracket does not sound exciting, but a manifold that is only hung on tubing will fatigue and leak. The heavy-duty bracket gives it a fixed support on a pipe stand or panel.
Specification table
| Parameter | Value |
|---|---|
| Part number | 01166-8005-0001 |
| Description | Manifold heavy duty mounting bracket, 316 SST |
| Fits | Rosemount 304 conventional manifold, traditional style |
| Wafer style | N/A |
| Model code option | VS, 316 SST for traditional style |
| Carbon steel alternative | 01166-8005-0002 (option VC) |
| Wafer-style bracket | 00305-0405-0001, SST 2-in. (50.8 mm) pipe mount (option B4) |
| Cold temperature manifold options | CW1 minus 67 deg F (minus 55 deg C), BR6 minus 76 deg F (minus 60 deg C) |
Mounting also affects performance of the whole measurement. A bracket with a firm fixing keeps the impulse connections free of mechanical load, and the manifold valves operate more consistently when the body does not flex under hand pressure. In facilities that perform regular calibration with the manifold equalising valve, a rigid bracket reduces the chance of a leak after repeated operation. The datasheet notes that manifolds are available in configurations meeting the ASME B31.1 and B31.3 power piping code, which specifies design criteria for air, gas, steam, water and oil systems in power plants and industrial facilities, so the bracket should be treated as part of a pressure-retaining assembly’s support system when designing for these codes.
Distinguishing 01166-8005-0001 from the other brackets in the datasheet
Rosemount lists several brackets. The 305 integral manifold has 2-in. pipe mount brackets (00305-0405-0001 SST, 00305-0405-0021 for a side-entry manifold) and panel brackets in CS (00305-0405-0010) and 316 SST (00305-0405-0012). The 304 wafer style uses 00305-0405-0001. The two heavy-duty brackets, 01166-8005-0001 in 316 SST and 01166-8005-0002 in carbon steel, are for the traditional 304 manifold, which is the flange-by-flange or flange-by-NPT body that carries more weight. Material choice depends on the environment: 316 SST for coastal or chemical atmospheres, CS for indoor, painted or dry duty.
Other spare parts for the 304 family in the datasheet include differential and gauge coplanar flange kits (00305-1001-0001 and 00305-1001-1001, wafer), DF adapter kits in several material combinations (for instance 03031-1300-0002 with SST adapters, CS bolts and glass-filled PTFE O-rings), socket weld adapter kits (03031-1320 series) and dielectric kits for gas metering. They share the same manifold body but serve entirely different purposes, so an RFQ that lists only the manifold model code can be matched to several parts; the part number of the bracket removes any doubt.
Where it is used
Traditional 304 manifolds appear on orifice-plate flow measurements, on separators, on gas metering skids and on level transmitters with flange connections. In the Gulf’s humid, salty air, 316 stainless brackets last longer than carbon steel, which is why many specifications simply require the SST version. The manifold itself is tagged with part number, schematic drawing, temperature and pressure limits, and that tag should remain visible once the bracket is installed.
The same instrument may need to withstand cold. The datasheet lists cold temperature manifold options CW1 and BR6, rated to minus 67 deg F (minus 55 deg C) and minus 76 deg F (minus 60 deg C), and these can be paired with Rosemount 3051 or 3051S transmitters that have the BR5 and BR6 options. In such cases the bracket must tolerate the same temperature, which 316 stainless steel does well, one more reason to choose the stainless version for exposed duty.
Mounting steps
- Select 01166-8005-0001 if the manifold is traditional style; do not use it with a wafer style manifold.
- Fit the bracket to the manifold body as shown in the manufacturer drawings.
- Secure the bracket to the pipe stand or panel with stainless fasteners to avoid galvanic problems.
- Check that valve handles can be turned and that the vent and drain ports are accessible.
- After tightening, check the process connections for leaks.
Maintenance
Check bracket bolts at each turnaround, as vibration from pumps and compressors loosens them. Look for corrosion at the contact area with the pipe. 316 stainless is robust, but crevice corrosion is possible in stagnant salt deposits, so rinse and inspect periodically. Record the bracket part number in the instrument datasheet.
When replacing a damaged bracket, lift the manifold weight using temporary support so the impulse connections are not stressed. Re-torque the process joints after the new bracket has been tightened, and check for leaks with the plant’s approved leak detection fluid. Where the manifold is of the five-valve natural gas pattern with dielectric kits, make sure the bracket does not bridge the insulating sleeves, as that would defeat the electrical isolation the kit is intended to provide.
Ordering notes
State 01166-8005-0001, the quantity, and the manifold style (traditional) on the RFQ. If the manifold is wafer style or a 305 integral, a different bracket from the datasheet is required, and we will confirm it from the model code.
Documents and quotation
The datasheet that lists 01166-8005-0001 in the 304 spare parts table is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send an RFQ with part number 01166-8005-0001, the quantity and your delivery location in Oman or the GCC.
Other Models in the Rosemount Manifold Spares Range
Seven Star LLC supplies models from the Rosemount Manifold Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Rosemount 00305-1000-0001 305 Module Sensor Guard | Instrument Valves & Fittings | View details |
| Rosemount 01166-8005-0001 304 Heavy Duty Bracket 316 SST | Instrument Valves & Fittings | You are viewing this model |
Datasheets & Documents
- Datasheet Rosemount 01166-8005-0001 304 Heavy Duty Bracket 316 SST Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile
Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments
Milestones
1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.
Rosemount products we list
FamilyModelsTypical use
Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams
Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.
FAQ
Questions about the Rosemount 01166-8005-0001 304 Heavy Duty Bracket
Answers from our engineering team on installation, compatibility and integration.
01What is Rosemount 01166-8005-0001?
It is the manifold heavy duty mounting bracket in 316 SST for the traditional-style Rosemount 304 conventional manifold.
02What is the carbon steel version?
The carbon steel heavy duty bracket is 01166-8005-0002, ordered as option VC in the model code.
03Can I use it on a wafer-style 304?
No. The datasheet lists the heavy duty brackets as not available for the wafer style; wafer manifolds use 00305-0405-0001 (option B4).
04Which option code corresponds to 01166-8005-0001?
Option VS, manifold heavy duty mounting bracket, 316 SST for traditional style.
05Which cold temperature options exist for these manifolds?
CW1 is rated to minus 67 deg F (minus 55 deg C) and BR6 to minus 76 deg F (minus 60 deg C) according to the datasheet.


















Reviews
There are no reviews yet.