Endress+Hauser CPA474 Cleanfit Plastic Retractable Assembly

Description

CPA474 Cleanfit: all-plastic wetted parts with a ball valve

Endress+Hauser CPA474 is the plastic version of the Cleanfit ball-valve retractable assemblies for pH and ORP electrodes. The datasheet stresses that only plastics (PP, PVDF, PEEK) touch the medium, which suits aggressive chemical, wastewater, industrial water, power plant and incinerator streams. A stainless steel version exists for high temperature and high pressure.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. The published technical information is TI345C, edition 04.10.

CPA474 values from the datasheet

Parameter Value
Construction Retractable plastic assembly with ball valve; manual, pneumatic or Topcal-controlled
Wetted parts Electrode holder PP, PEEK or PVDF; ball valve PP or PVDF; outlet seal and rinse socket PVDF; inlet seal PVDF, PTFE, Viton
Seals EPDM, FPM or perfluoroelastomer
Cylinder pressure PA cylinder 6 bar; stainless cylinder 10 bar at 40 degrees C
Pneumatic outlet seal 10 bar at 40 degrees C continuous; 4 bar at 130 degrees C up to 1 h
Manual outlet seal 10 bar at 20 degrees C; 2 bar at 130 degrees C
Manual insertion Process pressure must not exceed 4 bar
Compressed air 4 to 6 bar filtered, oil free; throttle accessory order number 50036864
Limit switches Pneumatic 3/2 way valve M12 x 1, hose 6 mm; electric NAMUR inductive, 10 m cable, 8 V, Ex ia IIC T6
Ambient Not below 0 degrees C; 80 degrees C maximum with a safety seal
Rinse fittings 2 x G 1/4 or NPT 1/4 inch
Weight 3 to 8 kg

Why choose the plastic assembly

A plastic body avoids metal contact with strong acids and chlorinated liquors, and it is lighter than CPA473, which weighs up to 15 kg. The ball valve gives safe process termination, and servicing is possible with a closed valve, including exchange of sealing rings and electrode holder. Pneumatic versions arrive with all hoses installed, shortening the installation time on site.

How CPA474 differs from CPA473 and CPA472D

CPA473 uses stainless steel wetted parts with PTFE-seated ball valve rated 16 bar at 130 degrees C, while CPA474 uses plastic parts and its outlet seal is rated up to 10 bar at 40 degrees C only. The sealing differs too: CPA474 uses two O-rings between drive and rinse chamber, where CPA473 uses a patented three-seal PEEK packing sleeve. Compared with CPA472D, there is no retraction safety stop mechanism here; instead the ball valve gives separation. Weight is 3 to 8 kg, the lowest of the three, and its pressure rating of 6 bar for the PA cylinder matches CPA473, while the stainless cylinder of either assembly reaches 10 bar.

Installation practice

  • Orient glass electrodes at least 15 degrees from horizontal; Tophit ISFET sensors can be mounted from 0 to 180 degrees.
  • Feed the rinse chamber from below and avoid siphon effects at the outlet.
  • Protect the rinse inlet and outlet with valves, since the chamber sees process pressure.
  • Use a flanged version for stainless cylinders mounted at an angle.
  • Add a pressure reducer if supply air can exceed 6 bar.

Accessories and controls for CPA474

For automatic cleaning and calibration the assembly works with Topcal CPC310 or Topclean CPC30, optionally with the CPR40 rinse block to connect two or four media. Two types of limit position switch are offered: a pneumatic 3/2 way valve with M12 x 1 thread for 6 mm hoses, or an inductive NAMUR type with a 10 m cable, 8 V nominal voltage, flush switching distance of 2 mm and an Ex ia IIC T6 marking. Hose connection sets in PVDF or stainless steel 1.4404, with G 1/4 or NPT 1/4 inch thread, link the rinse chamber to the plant. The pneumatic throttle with G 1/8 connection slows the stroke for smoother operation. A flow assembly, Flowfit CPA240, is listed for processes with a high level of requirements.

If the plant needs a sealing-water function, the pneumatic outlet safety seal for the rinse chamber outlet must be selected, and the ambient temperature may then not exceed 80 degrees C.

Using CPA474 at Oman sites

Chemical dosing stations, demineralisation plant regeneration wastewater and flue gas treatment loops at power stations are all duties where metal parts may corrode. The sealing-water function, which requires the pneumatic outlet safety seal, screens off the rinse chamber and is worth specifying for sticky media.

CPA474 questions answered briefly

What materials touch the process in Endress+Hauser CPA474? Only plastics: PP, PVDF and PEEK for the holder, PP or PVDF for the ball valve, with EPDM, FPM or perfluoroelastomer seals.

What pressure limits does CPA474 have? A PA pressure cylinder is rated 6 bar and a stainless steel cylinder 10 bar at 40 degrees C; manual assemblies must not exceed 4 bar during insertion or retraction.

Can CPA474 be automated? Yes, with Topcal CPC310 or Topclean CPC30 and the CPR40 rinse block, plus pneumatic or NAMUR limit position switches.

How is the sealing done on CPA474? Two O-rings seal between the pneumatic drive and the rinse chamber and an optional scraper sits on the process side of the ball valve.

What does the CPA474 weigh? 3 to 8 kg depending on the cylinder material, process connection, drive and additional equipment.

Documents and quotation

The datasheet for CPA474 is attached to this page. Please send an RFQ with CPA474, the cylinder material, process connection and drive type, and the quantity needed, and we will quote. If you are replacing an older plastic assembly, please note whether the drive is manual or pneumatic and whether limit switches are fitted, because those options change the order code. We can also quote the rinse hose sets, throttle and valves together so that the assembly arrives ready to hose up.

Delivery to Sites in Oman and the GCC

Delivery of the Endress+Hauser CPA474 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive instrument valves & fittings equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Other Models in the Cleanfit Range

Seven Star LLC supplies models from the Cleanfit range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Endress+Hauser CPA472D Cleanfit Heavy-Duty Retractable AssemblyInstrument Valves & FittingsView details
Endress+Hauser CPA474 Cleanfit Plastic Retractable AssemblyInstrument Valves & FittingsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Endress+Hauser CPA474 Cleanfit Plastic Retractable Assembly Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser CPA474 Cleanfit Plastic Retractable

Answers from our engineering team on installation, compatibility and integration.

01What materials touch the process in Endress+Hauser CPA474?
Only plastics: PP, PVDF and PEEK for the holder, PP or PVDF for the ball valve, with EPDM, FPM or perfluoroelastomer seals.
02What pressure limits does CPA474 have?
A PA pressure cylinder is rated 6 bar and a stainless steel cylinder 10 bar at 40 degrees C; manual assemblies must not exceed 4 bar during insertion or retraction.
03Can CPA474 be automated?
Yes, with Topcal CPC310 or Topclean CPC30 and the CPR40 rinse block, plus pneumatic or NAMUR limit position switches.
04How is the sealing done on CPA474?
Two O-rings seal between the pneumatic drive and the rinse chamber and an optional scraper sits on the process side of the ball valve.
05What does the CPA474 weigh?
3 to 8 kg depending on the cylinder material, process connection, drive and additional equipment.