- Automation & ControlView all 2,810 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: VEGA
VEGA VEGASWING 61 Vibrating Level Switch with DPDT Relay
Description
VEGA VEGASWING 61 vibrating level switch for liquids
The VEGA VEGASWING 61 is a compact tuning-fork level switch for all liquids. It works in any mounting position and detects the limit level with millimetre accuracy, so it can serve as an empty or full detector, as an approved overfill protection, as dry-run protection or as pump protection in vessels and pipelines. The fork is only 38 mm long, which keeps the sensor short. The version in this listing is the relay (DPDT) one, supplied with 20 to 253 V AC (50/60 Hz) or 20 to 72 V DC.
How a tuning fork switch senses the level
A vibration drive excites the fork at its resonance frequency. When liquid covers the fork, its frequency falls; the electronics turn that change into a switching command. Pressure, temperature, foam, viscosity and the composition of the liquid do not influence the switching accuracy, which also explains why set-up can be done without any medium in the vessel. The sheet lists a hysteresis of about 2 mm (0.08 in) for vertical installation.
VEGASWING 61 technical specifications
Values refer to the relay (DPDT) specification sheet.
| Parameter | Value (datasheet) |
|---|---|
| Model | VEGASWING 61, vibrating level switch for liquids, relay (DPDT) |
| Process pressure | -1 to +64 bar (-100 to +6400 kPa / -14.5 to +928 psig); function ensured to 100 bar at max +50 C (threaded versions) |
| Process temperature | -50 to +250 C (-58 to +482 F) |
| Viscosity, dynamic | 0.1 to 10000 mPa s |
| Density | 0.7 to 2.5 g/cm3; 0.5 to 2.5 g/cm3 by switching over |
| Ambient temperature | -40 to +70 C (-40 to +158 F) |
| Hysteresis | Approx. 2 mm (0.08 in) with vertical installation |
| Process fitting | Threads from G3/4, 3/4 NPT; flanges from DN 25, 1 in; hygienic fittings |
| Fork length | 38 mm |
| Operating voltage | 20 to 253 V AC, 50/60 Hz; 20 to 72 V DC |
| Output | Relay (DPDT); other versions: electronic switch, transistor, NAMUR, two-wire 8/16 mA |
Applications in Oman and the GCC
Pump protection on fuel, lube and process lines, overfill alarms on chemical and diesel day tanks, dry-run protection for transfer and booster pumps, high and low alarms in seal pots and drains, and level detection in pipelines are classic uses. The wide viscosity range, 0.1 to 10000 mPa s, covers water-like to heavy fluids, and the density window of 0.7 to 2.5 g/cm3 (0.5 to 2.5 by switching over) includes most hydrocarbons and aqueous media. The temperature range of -50 to +250 °C covers hot oil and cold service.
How VEGASWING 61 differs from VEGASWING 63 and VEGAWAVE 62
The VEGASWING 63 shares the electronics and data but adds a tube extension, so the switching point is set by the extension length for deeper installation, and the sheet names vessels rather than pipelines for it. The VEGAWAVE 62 is for powders and bulk solids rather than liquids, hung on a suspension cable, with 6 bar and +150 °C limits. The VEGASWING 61 is the short, direct-mount fork for liquids.
Fittings, pressure and electrical options
Fittings are threads from G¾ or ¾ NPT, flanges from DN 25 or 1 in, and hygienic fittings. Process pressure is -1 to +64 bar, while function is ensured up to 100 bar at a maximum of +50 °C with threaded versions. Ambient temperature is -40 to +70 °C. Other signal versions exist: contactless electronic switch, transistor (NPN/PNP), NAMUR and two-wire 8/16 mA.
Mounting, testing and ordering
Install with the fork gap oriented so liquid drains freely, and keep it clear of the inlet. Verify the switching function after installation by raising or lowering the level, or by dipping the fork in a sample liquid. For the quotation state the output version, fitting, wetted material and any approval, such as overfill protection approval or hazardous area certification. Tell us the density and viscosity of the liquid, since the density window of 0.7 to 2.5 g/cm3 can be extended down to 0.5 g/cm3 by switching over, and mention if the liquid tends to coat or crystallise, because heavy build-up on the fork can hold the signal. For dry-run protection of a pump, mount the fork above the pump suction with a margin for the hysteresis of about 2 mm and for the surge of the liquid. Where several switches protect one tank, using relay (DPDT) outputs allows two independent circuits, for example an alarm and an interlock, to be driven from one device.
VEGASWING 61 FAQ summary
- What can the VEGASWING 61 be used for? As empty or full detector, overfill protection, dry-run protection or pump protection in vessels and pipelines.
- How accurate is the VEGASWING 61 switching point? The sheet states millimetre accuracy and a hysteresis of about 2 mm with vertical installation.
- What temperature range does the VEGASWING 61 cover? Process temperature from -50 to +250 C and ambient from -40 to +70 C.
- Does foam or viscosity affect the VEGASWING 61? No, pressure, temperature, foam, viscosity and composition do not influence the switching accuracy according to the sheet.
- How long is the fork of the VEGASWING 61? Only 38 mm, and the device works independent of the installation position.
Documents and quotation
The manufacturer VEGA VEGASWING 61 datasheet is available as a PDF download on this page, so your engineers can check ranges, materials and dimensions against the data sheet before ordering. To request a quotation send the part number VEGASWING 61 together with the quantity, the required process connection, electronics version and any approval requirement through the RFQ form or by email. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer; product names and marks belong to their owners.
Selection Notes for the VEGA VEGASWING 61
When comparing the VEGA VEGASWING 61 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the VEGA level switches range and confirm the correct order code before you commit.
Datasheets & Documents
- Datasheet VEGA VEGASWING 61 Vibrating Level Switch for Liquids Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
VEGA is a German maker of level and pressure instruments. Bruno Grieshaber founded the company in 1959 in Triberg in the Black Forest, and it has been based in Schiltach since 1975, still family owned as VEGA Grieshaber KG. VEGA is best known for radar level sensors: it introduced the first two-wire radar level sensor in 1997 and the first 80 GHz radar sensor for bulk solids, the VEGAPULS 69, in 2015.
Seven Star LLC is an independent supplier listing VEGA radar and guided wave radar transmitters, point level switches, pressure transmitters and signal conditioning instruments for buyers in Oman and the GCC. Sensors are matched from the product code on the type label.
VEGA at a glance
| Origin | Founded by Bruno Grieshaber in 1959 in Triberg, Germany |
|---|---|
| Headquarters | Schiltach, Black Forest, Germany (since 1975) |
| Ownership | Family-owned company: VEGA Grieshaber KG |
| Milestones | First two-wire radar level sensor (1997), first 80 GHz radar for bulk solids, VEGAPULS 69 (2015), VEGAPULS 6X single radar platform for liquids and solids |
| Product families | VEGAPULS radar, VEGAFLEX guided wave radar, VEGASWING and VEGAPOINT switches, VEGACAL capacitive probes, VEGABAR and VEGADIF pressure, VEGAMET and VEGADIS signal conditioning |
VEGA sensor and instrument series
| Series | Type | Typical use |
|---|---|---|
| VEGAPULS 6X, VEGAPULS 69, VEGAPULS 64 | Process radar level transmitters (80 GHz) | Storage and process tanks, reactors with agitators, silos and bulk solids |
| VEGAPULS 11, 21, 31, 42 | Compact radar sensors | Water and wastewater, simple storage tanks; VEGAPULS 42 with IO-Link for machine integration |
| VEGAPULS C 21, C 11, C 22, C 23 | Radar sensors with fixed cable, IP68 | Wet wells, pumping stations, open channels and river levels |
| VEGAFLEX 81, 82, 83, 86 | Guided wave radar (TDR) | Level and interface in liquids, bulk solids, hygienic and high-temperature or high-pressure service (VEGAFLEX 86) |
| VEGASWING 61, 63, VEGAPOINT 21 | Vibrating and capacitive point level switches | Overfill protection, dry-run protection and high or low level alarms |
| VEGACAL 62 to VEGACAL 67 | Capacitive rod and cable probes | Point and continuous level in solids and conductive or adhesive liquids |
| VEGABAR 82, 83, 28, 29, 38 | Pressure transmitters, ceramic or metallic cell | Process pressure and hydrostatic level; compact 18/19 and 28/29/38 versions for utilities |
| VEGADIF 85 | Differential pressure transmitter | DP flow, filter monitoring and level in pressurised vessels |
| VEGAMET 841, VEGADIS 176 | Controller and loop display | Level display, pump control and remote indication of 4-20 mA signals |
Where VEGA instruments are used
VEGA radar sensors measure level in crude oil and product tanks, separators, chemical reactors, cement and aggregate silos, grain stores and water reservoirs. Compact cable radars are widely used in wastewater pumping stations and flood monitoring. Because 80 GHz radar focuses a narrow beam, it can measure past internal structures in a tank, and it is not affected by the temperature, pressure or vapour above the product, which suits hot Gulf storage tanks.
Ordering VEGA instruments: what we need
The product code on the type label (for example PS64.XXXXXXX) fixes the measuring range, antenna or probe, process connection, electronics and approvals. Send it with the serial number. For a new measurement add the medium and its dielectric constant if known, tank or silo height and internals, process pressure and temperature, process connection, output (4-20 mA HART, PROFIBUS PA, Modbus or IO-Link), and any hazardous-area or overfill protection approval required.
Facts checked against VEGA company and product information, October 2026.
Browse VEGA products by category: Level Transmitter, Pressure Instrumentation, Controllers and Data Acquisition.
FAQ
Questions about the VEGA VEGASWING 61 Vibrating Level Switch with DPDT
Answers from our engineering team on installation, compatibility and integration.
01What can the VEGASWING 61 be used for?
As empty or full detector, overfill protection, dry-run protection or pump protection in vessels and pipelines.
02How accurate is the VEGASWING 61 switching point?
The sheet states millimetre accuracy and a hysteresis of about 2 mm with vertical installation.
03What temperature range does the VEGASWING 61 cover?
Process temperature from -50 to +250 C and ambient from -40 to +70 C.
04Does foam or viscosity affect the VEGASWING 61?
No, pressure, temperature, foam, viscosity and composition do not influence the switching accuracy according to the sheet.
05How long is the fork of the VEGASWING 61?
Only 38 mm, and the device works independent of the installation position.


















Reviews
There are no reviews yet.