Brand:

Pepperl+Fuchs KFA5-DWB-Ex1.D Speed Monitor 115 V AC

Description

KFA5-DWB-Ex1.D: intrinsically safe speed watchdog for 115 V AC cabinets

Where the only auxiliary power in a control cabinet is 115 V AC, the Pepperl+Fuchs KFA5-DWB-Ex1.D still brings rotation-speed supervision into hazardous areas. A NAMUR sensor or dry contact in the field produces pulses; the module counts them between 1 mHz and 5 kHz and compares the rate with the limits typed in on the keypad. Two relays then report overspeed and underspeed.

The supply draws 30 mA at 115 V AC plus or minus 10 percent, with a power consumption of 2 VA, so the module is a negligible load on a small control transformer.

Characteristics

  • Input I on terminals 1+ and 3-: Ex ia, Uo 10.1 V, Io 13.5 mA, Po 34 mW
  • Input II on terminals 13+ and 14-: start-up override from 1 to 1000 s
  • Measuring accuracy 0.1 percent of measured value; measuring time below 100 ms
  • Relays on terminals 10, 11, 12 and 16, 17, 18: 253 V AC at 2 A, 40 V DC at 2 A
  • Line fault detection indicated by the red LED and by the relay, and SIL 2 capability

KFA5-DWB-Ex1.D data table

Parameter Value
Supply 115 V AC plus or minus 10 percent, terminals 23 and 24
Rated current 30 mA
Power 2 VA dissipation and consumption
Frequency range 0.001 to 5000 Hz
Pulse duration above 50 microseconds
Line fault limits breakage 0.15 mA or less; short circuit above 6.5 mA
Response delay of relays 200 ms or less
Relay mechanical life 5 x 10 to the power 7 cycles
Isolation reinforced, 300 Veff between input, outputs and supply
Certificates TUV 99 ATEX 1408; TUV 02 ATEX 1885 X; IECEx TUN 03.0000
Dimensions, mass 40 x 119 x 115 mm, housing C2, 300 g
Ambient -20 to 60 degrees C, IP20

Place in the speed-monitor group

  • KFA5-DWB-Ex1.D operates from 115 V AC; KFA6-DWB-Ex1.D from 230 V AC at 18 mA; KFD2-DWB-Ex1.D from 24 V DC with Power Rail.
  • All three share the 5 kHz Ex ia input and the same relay ratings.
  • KFD2-DWB-1.D extends the range to 12 kHz but without the hazardous-area input.

Example duty: compressor lube-oil pump

A lube-oil pump shaft fitted with an inductive sensor on a 4-tooth wheel turns at 1,500 rpm and produces 100 Hz. The monitor is set so that relay I opens below 80 Hz (underspeed) and relay II opens above 120 Hz (overspeed). A start-up override of 20 s prevents the underspeed relay from tripping while the pump accelerates. Because the module accepts frequencies down to 1 mHz, it also copes with slow rotating equipment such as kiln drives.

Installation

Mount on a DIN rail, run mains to terminals 23 and 24 through a suitable fuse and keep intrinsically safe wiring in a separate, labelled duct. Program the limits and test with a signal generator before the sensor is connected. Interlock wiring from the relays should follow the plant fail-safe convention.

Care

Test both relays annually. Verify that the display and keypad function, and that line fault indication reacts when the sensor cable is disconnected.

Commissioning tests for a speed monitor

With the cabinet de-energised, check the polarity of the sensor wiring on terminals 1+ and 3-. Energise, and use a signal generator or a calibrated pulse source to step the frequency through the lower limit and the upper limit, noting the frequencies at which the relays change state. The two points should agree with the programmed values within the 0.1 percent measuring accuracy plus the generator tolerance. Next test the start-up override by switching input II and observe that the relays hold the programmed state for the configured time. Finally simulate a broken sensor wire and a short circuit to confirm that the line-fault LED lights and the relay moves to its safe state.

Choosing limits sensibly

Set the underspeed limit well below the normal running frequency but above the speed at which the driven equipment is damaged or loses its process function, and the overspeed limit comfortably above normal speed yet below the mechanical limit of the machine. For a pump that normally runs at 100 Hz of sensor pulses, a typical underspeed point is 80 percent and overspeed 115 to 120 percent. Variations due to load, slip and supply frequency must be considered. Record the chosen limits and the reasoning in the loop file, because they will be questioned after an unexpected trip.

Questions buyers ask about KFA5-DWB-Ex1.D

What supply does KFA5-DWB-Ex1.D use? It uses 115 V AC plus or minus 10 percent on terminals 23 and 24, with a rated current of 30 mA.

What frequency range does KFA5-DWB-Ex1.D cover? The measurement range is 0.001 to 5000 Hz with 0.1 percent accuracy.

How does the start-up override of KFA5-DWB-Ex1.D work? Input II holds the relays in a programmed state for 1 to 1000 seconds so that a machine can start without nuisance trips.

What are the safe-side values of KFA5-DWB-Ex1.D? Input I is Ex ia with Uo 10.1 V, Io 13.5 mA and Po 34 mW.

Is KFA5-DWB-Ex1.D capable of SIL 2? The datasheet lists a safety integrity level of SIL 2 according to IEC/EN 61508 and IEC/EN 61511.

Documents and quotation

The manufacturer datasheet for KFA5-DWB-Ex1.D accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Quote the sensor type and the shaft pulse frequency. To request a quotation, send the RFQ with the exact part number KFA5-DWB-Ex1.D, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Spares and Lifecycle Considerations

For critical service, many plants hold one Pepperl+Fuchs KFA5-DWB-Ex1.D as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical isolator & barrier units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.

Other Models in the Dwb Speed Range

Seven Star LLC supplies models from the Dwb Speed range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pepperl+Fuchs KFD2-DWB-1.D Speed Monitor 12 kHzIsolator & BarrierView details
Pepperl+Fuchs KFA6-DWB-Ex1.D Speed Monitor 230 V ACIsolator & BarrierView details
Pepperl+Fuchs KFA5-DWB-Ex1.D Speed Monitor 115 V ACIsolator & BarrierYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Pepperl+Fuchs KFA5-DWB-Ex1.D Speed Monitor 115 V AC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.

Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.

Pepperl+Fuchs company profile

Founded 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs
Headquarters Mannheim, Germany
Ownership Privately owned (Pepperl+Fuchs SE)
Origins Radio repair workshop that began making replacement transformers
Product families Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures

Milestones

  • 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
  • 1958: The first proximity switch is developed (some company sources say 1959).

Pepperl+Fuchs product families on this page

On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.

Where Pepperl+Fuchs equipment is used

Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.

Pepperl+Fuchs products we list

Family Examples
Isolator & Barrier HiD2030 SMART Transmitter Power Supply w…, KFD2-SR2-Ex2.W K-System Isolated Switch…, KFD2-UT2-Ex2 Universal Temperature Conve…
Industrial Computers Tab-Ex 05 DZ1 WWAN Hazardous Area Tablet, Smart-Ex® 03 DZ2 smartphone for Zone 2/2…
Inductive Proximity Sensors NJ2-12GK-SN NAMUR Inductive Sensor
Power Modules PS1000-A6-24.20 Power Supply 24 VDC 20 A
Photoelectric Sensors R101 Retro-Reflective Photoelectric Sensor
Laser Distance, LiDAR & Radar Sensors R2000 2-D LiDAR Laser Scanner

Ordering Pepperl+Fuchs parts: what we need

Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.

Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.

FAQ

Questions about the Pepperl+Fuchs KFA5-DWB-Ex1.D Speed Monitor 115 V AC

Answers from our engineering team on installation, compatibility and integration.

01What supply does KFA5-DWB-Ex1.D use?
It uses 115 V AC plus or minus 10 percent on terminals 23 and 24, with a rated current of 30 mA.
02What frequency range does KFA5-DWB-Ex1.D cover?
The measurement range is 0.001 to 5000 Hz with 0.1 percent accuracy.
03How does the start-up override of KFA5-DWB-Ex1.D work?
Input II holds the relays in a programmed state for 1 to 1000 seconds so that a machine can start without nuisance trips.
04What are the safe-side values of KFA5-DWB-Ex1.D?
Input I is Ex ia with Uo 10.1 V, Io 13.5 mA and Po 34 mW.
05Is KFA5-DWB-Ex1.D capable of SIL 2?
The datasheet lists a safety integrity level of SIL 2 according to IEC/EN 61508 and IEC/EN 61511.