Pepperl+Fuchs KCD2-SR-Ex1 Switch Amplifier, 12.5 mm
Description
Pepperl+Fuchs KCD2-SR-Ex1 overview
The Pepperl+Fuchs KCD2-SR-Ex1 is a one-channel isolated barrier from the K-System of Pepperl+Fuchs that transfers digital signals from NAMUR sensors or dry contacts in a hazardous area to the safe area through a relay contact output. It has a housing only 12.5 mm wide, which suits space-critical cabinets and positions, end stops and switching states.
The datasheet released on 27 August 2026 states that the mode of operation can be reversed and the line fault detection switched off by DIP switches. During a fault the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44, and a collective error message is available when the device is operated through the Power Rail.
Key features of the Pepperl+Fuchs KCD2-SR-Ex1
- One-channel isolated barrier in a 12.5 mm wide housing
- Dry contact or NAMUR input with line fault detection
- Relay contact output, reversible mode of operation
- Up to SIL 2 with systematic capability SC 3
- Powered from 19 to 30 V DC via Power Rail or terminals 9 and 10
- Power dissipation of only up to 600 mW
- Ambient temperature from minus 40 to 70 degrees C
- Collective error message through the Power Rail
KCD2-SR-Ex1 technical specifications
The values below are taken from the manufacturer datasheet of the KCD2-SR-Ex1, release date 2026-08-27. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | KCD2-SR-Ex1, Switch Amplifier, 1-channel isolated barrier |
| Signal type | Digital input |
| Safety integrity | SIL 2, systematic capability SC 3 |
| Supply | 19 to 30 V DC, Power Rail or terminals 9+, 10- |
| Rated current | Up to 29 mA |
| Power dissipation / consumption | Up to 600 mW / up to 600 mW |
| Input | NAMUR acc. to EN 60947-5-6, terminals 1+, 2- |
| Open circuit voltage / short-circuit current | About 8 V DC / about 8 mA |
| Switching point / hysteresis | 1.2 to 2.1 mA / about 0.2 mA |
| Line fault detection | Breakage 0.1 mA or less; short-circuit 6.5 mA or more |
| Output | Relay, terminals 5, 6; 250 V AC / 2 A / cos phi above 0.75; 126.5 V AC / 4 A; 30 V DC / 2 A resistive |
| Delay / switching frequency | Up to 20 ms / up to 10 Hz |
| Ambient temperature | Minus 40 to 70 degrees C |
| Dimensions / mass | 12.5 x 119 x 114 mm (W x H x D), housing type A2 / about 100 g |
The hazardous-area parameters are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.
Typical applications in oil and gas, utilities, water and manufacturing
Position and process switching in hazardous areas relies on NAMUR proximity sensors and dry contacts, from limit switches on emergency shutdown valves at wellheads to level switches on storage tanks and flow switches on cooling water lines. The KCD2-SR-Ex1 passes these signals out of the hazardous area to relays, PLC inputs or annunciators, and its line fault detection tells operators when a cable is open or shorted instead of leaving a silent failure.
In power stations, water treatment plants and manufacturing facilities around the GCC, the same module is common on package units, burner management panels and compressor skids. Because the signal is a simple switching state, the KCD2-SR-Ex1 is easy to commission, and spare units are often held on the shelf because one failed channel can stop a whole skid.
Selection and compatibility notes for KCD2-SR-Ex1
Check the sensor type first. The input is designed for NAMUR sensors according to EN 60947-5-6 and for mechanical contacts with the resistor network shown in the wiring diagram, so a three-wire sensor or a powered contact needs a different interface. Then check what the safe-area load requires, because a relay output and a transistor output behave very differently with PLC cards, solenoids and counters.
If the signal is part of a safety function, read the functional safety data in the datasheet, including the SIL value and the conditions attached to it, and compare it with your safety requirement specification. When the KCD2-SR-Ex1 replaces an older module, compare terminal numbers and the supply arrangement, since the Power Rail option changes how power and the collective error message are wired.
Installation and commissioning of the KCD2-SR-Ex1
Before mounting the KCD2-SR-Ex1, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail, a termination board or its own supply terminals. Mount it in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits.
Wire the KCD2-SR-Ex1 only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the KCD2-SR-Ex1 can be compared with the commissioning values.
Maintenance and service life
The KCD2-SR-Ex1 has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the KCD2-SR-Ex1 entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the KCD2-SR-Ex1 often need neighbouring models or accessories from the same system, such as other K-System isolated barriers, the Power Rail and power feed modules, KFA6 power supplies and the matching NAMUR sensors. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.
When you send an enquiry for the KCD2-SR-Ex1, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about KCD2-SR-Ex1
The KCD2-SR-Ex1 is a 12.5 mm wide, SIL 2 capable one-channel switch amplifier with a relay output, NAMUR or dry contact input, line fault detection and operation from the Power Rail.
Documents and quotation
A copy of the manufacturer datasheet for the KCD2-SR-Ex1 is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number KCD2-SR-Ex1, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Datasheets & Documents
- Datasheet KCD2-SR-Ex1 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KCD2-SR-Ex1 Switch Amplifier, 12.5 mm
Answers from our engineering team on installation, compatibility and integration.
01How wide is the KCD2-SR-Ex1?
The housing is 12.5 mm wide, type A2, which allows high channel density in a cabinet.
02What can be connected to the input of the KCD2-SR-Ex1?
NAMUR sensors according to EN 60947-5-6 and dry contacts with the resistor network shown in the wiring diagram.
03What is the supply for the KCD2-SR-Ex1?
It needs 19 to 30 V DC, taken from the Power Rail or from terminals 9+ and 10-.
04Which documents are available for the KCD2-SR-Ex1?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the KCD2-SR-Ex1.
05How do I order the KCD2-SR-Ex1?
Send an RFQ with the part number KCD2-SR-Ex1, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.


















Reviews
There are no reviews yet.