- Automation & ControlView all 2,759 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Pepperl+Fuchs
Pepperl+Fuchs HiC2025ES SMART Transmitter Power Supply, SIL 3
Description
Pepperl+Fuchs HiC2025ES overview
The Pepperl+Fuchs HiC2025ES is the enhanced version of the HiC2025 SMART transmitter power supply from Pepperl+Fuchs. It is a one-channel isolated barrier that supplies 2-wire transmitters in a hazardous area, can be used with current sources, and adds line fault detection together with a separate fault output on the bus. A fault is reported if the input signal lies outside the range of 3 to 22 mA.
The datasheet released on 1 June 2023 states a safety integrity level of up to SIL 3 and lists HART as the supported SMART protocol. Like the other devices of this series, it plugs into a HiC termination board, is bus powered, and has an output that is selected as current source, current sink or voltage source with DIP switches.
Key features of the Pepperl+Fuchs HiC2025ES
- One-channel isolated barrier with line fault detection and a separate fault output
- Up to SIL 3 according to IEC/EN 61508, systematic capability SC 3
- Fault signalled if the input is outside 3 to 22 mA, with downscaling at 3 mA or less and upscaling at 22 mA or more
- Output selectable by DIP switch: 4 to 20 mA source or sink, or 1 to 5 V
- Bi-directional HART communication
- Bus powered, 19 to 30 V DC, through the HiC termination board
- Ambient temperature from minus 20 to 70 degrees C, IP20
- Housing width 12.5 mm
HiC2025ES technical specifications
The values below are taken from the manufacturer datasheet of the HiC2025ES, release date 2023-06-01. Always confirm the current datasheet and the certificates before final engineering.
| Parameter | Value |
|---|---|
| Model | HiC2025ES, SMART Transmitter Power Supply, 1-channel isolated barrier |
| Signal type | Analog input |
| Safety integrity | SIL 3, systematic capability SC 3 |
| Supply | 19 to 30 V DC, bus powered via termination board |
| Rated current | Up to 50 mA |
| Power dissipation / consumption | Up to 800 mW / up to 1.2 W |
| Input | 4 to 20 mA, limited to about 27 mA, reverse polarity protected |
| Line fault detection | Downscaling 3 mA or less; upscaling 22 mA or more |
| Available voltage | At least 15 V at 20 mA |
| Output, source mode | 4 to 20 mA or 1 to 5 V (internal 250 ohm resistor), load 0 to 300 ohm |
| Output, sink mode | 4 to 20 mA, operating voltage 16 to 28 V |
| Fault output | Open collector transistor on the internal fault bus, terminal 6b |
| Deviation at 20 degrees C | Up to 20 microamperes in current modes; up to 10 mV in 1 to 5 V mode |
| Settling time / rise time | Up to 200 ms / up to 20 ms |
| Ambient temperature | Minus 20 to 70 degrees C |
| Dimensions / mass | 12.5 x 106 x 128 mm (W x H x D) / about 100 g |
The hazardous-area parameters are listed per terminal pair in the datasheet. Use the entity values of the exact terminals you wire, and refer to the certificate for the permitted cable parameters of your installation.
Typical applications in oil and gas, utilities, water and manufacturing
Loop-powered SMART transmitters for pressure, differential pressure, level, flow and temperature are found throughout refineries, gas gathering stations, power plants and desalination works in Oman and the wider GCC. Where such a transmitter sits in a hazardous area, an intrinsically safe interface is needed between the field and the control room, and the HiC2025ES is designed for that duty in marshalling cabinets feeding DCS and PLC analog input channels.
In utilities, water and wastewater works and manufacturing sites, the same interface is typical near fuel stores, chemical dosing areas and biogas digesters. Because HART data can pass through the module, asset management software and handheld communicators can reach the transmitter for configuration and diagnostics, which is one reason buyers specify the HiC2025ES as a like-for-like spare.
Selection and compatibility notes for HiC2025ES
Begin with the transmitter. Confirm that its supply voltage requirement, its current range and its entity parameters match the field-side data of the HiC2025ES, and confirm that the control system input accepts the output type of the module. Check the loop resistance as well, since HART communication needs enough load in the loop.
Then consider the cabinet. Decide early how power will be distributed, because the HiC2025ES is intended for the supply method named in the datasheet, and check that the housing width suits your rack or termination arrangement. If your plant standard calls for another channel count or safety integrity level, tell us before ordering so that we can compare neighbouring variants against your loop list.
Installation and commissioning of the HiC2025ES
Before mounting the HiC2025ES, confirm the field device and cable parameters against the entity values in the datasheet and the certificate, and decide whether the module will be powered from a Power Rail, a termination board or its own supply terminals. Mount it in a clean, ventilated cabinet in the safe area, keep hazardous-area and safe-area wiring physically separated and labelled, and respect the spacing and marking required by your site rules for intrinsically safe circuits.
Wire the HiC2025ES only to the terminal assignment printed in the wiring diagram, tighten the screws and check that no strands are left outside the clamp. After applying the supply, check the power indication, then simulate the field signal and prove the complete loop from field to control system before the plant is handed over. Record the as-found readings so that later loop checks of the HiC2025ES can be compared with the commissioning values.
Maintenance and service life
The HiC2025ES has no serviceable parts, so maintenance is mostly inspection. During planned shutdowns, check terminals for looseness and corrosion, verify the supply voltage at the module, and repeat the loop check that was recorded at commissioning. In coastal and humid locations such as Muscat, Sohar and Duqm, a clean, dry and sealed cabinet greatly extends the life of any electronic interface.
If a loop drifts out of tolerance or the unit shows no power indication with a healthy supply, replace the module instead of attempting a repair, and keep the replacement documentation in the loop folder. Certified intrinsically safe equipment must not be modified, and any change to cabling, load or field device should be re-assessed against the HiC2025ES entity parameters before it returns to service.
Related products and ordering notes
Customers who ask for the HiC2025ES often need neighbouring models or accessories from the same system, such as other HiC series isolated barriers, HiC termination boards and neighbouring SMART transmitter supplies and current drivers. If you are standardising a cabinet or a spare parts list on one family, send us the loop list or the equipment list and we can quote the matching items together.
When you send an enquiry for the HiC2025ES, quote the full part number exactly as printed on the nameplate, the quantity and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the exact variant you need. We can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about HiC2025ES
The HiC2025ES is a one-channel SIL 3 capable barrier for 2-wire SMART transmitters with line fault detection, a separate fault output, HART support and a switchable 4 to 20 mA or 1 to 5 V output.
Documents and quotation
A copy of the manufacturer datasheet for the HiC2025ES is attached to this page for your engineering review. To request a quotation, send the RFQ with the part number HiC2025ES, the quantity, the delivery location and any certification or documentation requirements, and we will reply with availability and lead time. Please check the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Datasheets & Documents
- Datasheet HiC2025ES Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs HiC2025ES SMART Transmitter Power
Answers from our engineering team on installation, compatibility and integration.
01How does the HiC2025ES differ from the HiC2025?
The ES version adds line fault detection with a separate fault output and is rated up to SIL 3, while the HiC2025 is rated up to SIL 2.
02When does the HiC2025ES signal a fault?
A fault is signalled if the input signal is outside the range of 3 to 22 mA, using downscaling at 3 mA or less or upscaling at 22 mA or more.
03Which protocol does the HiC2025ES support?
The datasheet lists HART as the supported SMART protocol, with bi-directional communication through the barrier.
04Which documents are available for the HiC2025ES?
The manufacturer datasheet is attached to this page, and certificates or manuals can be requested together with your RFQ for the HiC2025ES.
05How do I order the HiC2025ES?
Send an RFQ with the part number HiC2025ES, the quantity and the delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.


















Reviews