Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-STC5-Ex1.H High Voltage Supply
Description
KFD2-STC5-Ex1.H: higher voltage for demanding transmitters
Some SMART transmitters, especially older analyser heads, flow meters with heaters or devices with long cable runs, need more voltage than a standard supply provides. The Pepperl+Fuchs KFD2-STC5-Ex1.H raises the available field voltage to 17 V DC at 20 mA and 21 V at 4 mA (24 V open circuit), against 16 V and 20 V for the standard model.
In every other respect it is a one-channel barrier with a 4 to 20 mA output that can be configured as sink or source on the safe side.
Selected features
- High field voltage 17 V DC at 20 mA
- Output 4 to 20 mA into 0 to 800 ohm; overload above 25 mA
- If the external supply is above 19 V, a load of at least (V minus 19) divided by 0.02 ohm is required, and the internal 250 ohm resistor at terminal 9 may serve as that load
- HART, BRAIN and Foxboro supported
- Extended ambient range up to 70 degrees C under the mounting conditions described in the manual
KFD2-STC5-Ex1.H figures
| Parameter | Value |
|---|---|
| Supply | 18 to 30 V DC, up to 1 W dissipation, up to 1.6 W consumption |
| Input | 4 to 20 mA, terminals 1+, 2-, 3 |
| Open-circuit voltage / short-circuit current | 24 V / 25 mA |
| Available voltage | 17 V at 20 mA, 21 V at 4 mA |
| Output | 4 to 20 mA sink or source, 0 to 800 ohm |
| Settling time | 500 microseconds |
| Safe-side values | Uo 27.2 V, Io 93 mA, Po 633 mW |
| Certificate | CML 17 ATEX 2029X |
| Ambient | -20 to 60 degrees C (up to 70 degrees C with mounting conditions) |
| Dimensions, mass | 20 x 124 x 115 mm, about 200 g |
Deciding whether you need the H version
Add up the minimum operating voltage of the transmitter and the voltage drop of the cable at 20 mA. A transmitter that needs 15.5 V and sits on a 100 ohm cable loop (2 V drop) would be at the edge with a supply that delivers 16 V, but gets 1.5 V of margin with 17 V. In practice the H variant is the safe pick when the transmitter datasheet quotes a minimum of 15 V or more, or when a hazardous-area junction box adds protective components in series.
KFD2-STC5-Ex1.H compared with other versions
Against KFD2-STC5-Ex1 the available voltage is 1 V higher and the open-circuit voltage 24 V instead of 23 V, but settling slows from 200 to 500 microseconds and the normal ambient limit drops from 70 to 60 degrees C. Against KFD2-STC5-Ex1.2O it keeps a single output and a load limit of 0 to 800 ohm.
Installation
The wiring diagram mirrors the standard STC5. Use the sink or source terminals according to the control system and add the series resistor if the external voltage exceeds 19 V. Fit to a 35 mm rail or Power Rail, observing the spacing that permits the 70 degrees C operation described in the manual.
Upkeep
Check transmitter voltage at the field terminals with a loop at 20 mA and confirm that it exceeds the device minimum. Document the result.
Selection summary
Choose this variant for demanding transmitters; select the standard type for speed and the widest temperature range.
Voltage budget example
Consider a transmitter that needs at least 16.5 V at the terminals and sits at the end of 800 m of cable with 0.1 ohm per metre per conductor, giving 160 ohm of loop resistance. At 20 mA the cable drops 3.2 V, so the barrier must offer at least 19.7 V at its field terminals. The H version supplies 17 V at 20 mA in the datasheet, so a shorter cable or a transmitter with a lower minimum voltage is still necessary; the example shows why the budget has to be calculated and not guessed. Larger conductors or a transmitter local to the junction box restore the margin.
Mounting for the extended temperature range
The datasheet states that operation up to 70 degrees C is possible, but only when the mounting conditions in the manual are observed, typically meaning spacing between devices and the use of a specific orientation. In an Omani coastal cabinet with high humidity and sun load, assume the standard 60 degrees C limit unless the cabinet temperature is measured and proven. Mounting each module on a DIN rail with free air at the sides reduces self-heating from the roughly 1 W dissipation. Mixed rows with high-dissipation power supplies are best avoided.
Questions buyers ask about KFD2-STC5-Ex1.H
What field voltage does KFD2-STC5-Ex1.H deliver? It provides at least 17 V at 20 mA and 21 V at 4 mA on terminals 1+ and 3, with a 24 V open-circuit voltage.
When is a series resistor needed with KFD2-STC5-Ex1.H? If the external voltage is above 19 V, a load of at least (V minus 19) divided by 0.02 ohm is required, and the internal 250 ohm resistor can be used.
What is the settling time of KFD2-STC5-Ex1.H? The settling time is 500 microseconds, slower than the 200 microseconds of the standard STC5 model.
What ambient temperature applies to KFD2-STC5-Ex1.H? The standard range is -20 to 60 degrees C, with an extended range up to 70 degrees C under mounting conditions in the manual.
What output load can KFD2-STC5-Ex1.H drive? The load range is 0 to 800 ohm with overload above 25 mA.
Documents and quotation
The manufacturer datasheet for KFD2-STC5-Ex1.H accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Quote the transmitter minimum voltage with your request. To request a quotation, send the RFQ with the exact part number KFD2-STC5-Ex1.H, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-STC5-Ex1.H High Voltage Supply Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-STC5-Ex1.H High Voltage Supply
Answers from our engineering team on installation, compatibility and integration.
01What field voltage does KFD2-STC5-Ex1.H deliver?
It provides at least 17 V at 20 mA and 21 V at 4 mA on terminals 1+ and 3, with a 24 V open-circuit voltage.
02When is a series resistor needed with KFD2-STC5-Ex1.H?
If the external voltage is above 19 V, a load of at least (V minus 19) divided by 0.02 ohm is required, and the internal 250 ohm resistor can be used.
03What is the settling time of KFD2-STC5-Ex1.H?
The settling time is 500 microseconds, slower than the 200 microseconds of the standard STC5 model.
04What ambient temperature applies to KFD2-STC5-Ex1.H?
The standard range is -20 to 60 degrees C, with an extended range up to 70 degrees C under mounting conditions in the manual.
05What output load can KFD2-STC5-Ex1.H drive?
The load range is 0 to 800 ohm with overload above 25 mA.


















Reviews