Brand: Pepperl+Fuchs
Pepperl+Fuchs KFD2-DWB-1.D Speed Monitor 12 kHz
Description
KFD2-DWB-1.D: Pepperl+Fuchs speed monitor for non-hazardous inputs
Not every speed-supervision loop needs an intrinsically safe input, and the Pepperl+Fuchs KFD2-DWB-1.D exists for those that do not. It is a one-channel signal conditioner that takes the pulses of a NAMUR proximity switch or a mechanical contact, compares their frequency with limits set on the front keypad, and drives two relays. Its input ceiling of 12 kHz is the highest in the DWB group, which makes it the choice when a shaft carries many teeth or turns quickly.
The housing is the familiar 40 mm wide type C2 module with green removable terminals, and power comes from 24 V DC or from the Power Rail so a row of units can share one feed.
Strengths worth noting
- Frequency range 0.001 to 12000 Hz, accuracy 0.1 percent of the measured value, measuring time under 100 ms
- Accepts two-wire sensors on terminals 1+ and 3-, or three-wire sensors on 1+, 2- and 3
- Switching point: logic 1 above 2.5 mA, logic 0 below 1.9 mA; input resistance 4.7 kilohm; open-circuit voltage 22 V, short-circuit current 40 mA
- Line-fault limits of 0.15 mA or less for breakage and above 4 mA for a short circuit
- Start-up override of 1 to 1000 s through input II on terminals 13+ and 14-
Data table for KFD2-DWB-1.D
| Parameter | Value |
|---|---|
| Type | 1-channel signal conditioner, SIL 2 capable (IEC/EN 61508) |
| Supply | 20 to 30 V DC, about 100 mA, up to 1.8 W |
| Sensor input | NAMUR to EN 60947-5-6 or dry contact, 2- or 3-wire |
| Pulse duration | above 50 microseconds |
| Measuring range | 0.001 to 12000 Hz |
| Temperature drift | 0.003 percent per K |
| Relay contacts | 250 V AC / 2 A / cos phi 0.7 or better; 40 V DC / 2 A |
| Mechanical relay life | 5 x 10 to the power 7 cycles |
| Output delay | about 20 ms on and off; total response 200 ms or less |
| Isolation | reinforced, 300 Veff, input and outputs against other circuits |
| Zone 2 certificate | PF 08 CERT 1216 X, Ex nA nC IIC T4 Gc, with 40 V DC / 1 A relay loading and 50 V AC / 2 A in that mode |
| Ambient range | -20 to 60 degrees C (Zone 2 use: -20 to 50 degrees C) |
| Dimensions and mass | 40 x 119 x 115 mm, 300 g, IP20 |
| Approval | UL E223772 |
How the 12 kHz capability helps
A 60-tooth wheel on a shaft turning at 3,000 rpm produces 3 kHz, and a 120-tooth wheel on a gearbox output stage at 6,000 rpm reaches 12 kHz. Lower-ceiling monitors would need a prescaler in such cases. Here the conditioner measures the pulses directly, which removes a component from the cabinet and one potential fault source.
Differences between KFD2-DWB-1.D and its relatives
Placed next to KFD2-DWB-Ex1.D, the KFD2-DWB-1.D trades the intrinsically safe input for a doubled frequency ceiling (12 kHz instead of 5 kHz) and a three-wire sensor option. It does not carry the ATEX Ex ia input marking, so the sensor must be located in a safe area or in a Zone 2 or Division 2 location under the stated Ex nA conditions. The 230 V AC and 115 V AC cousins, KFA6-DWB-Ex1.D and KFA5-DWB-Ex1.D, keep the Ex ia input and the 5 kHz limit but change the power supply.
Installation pointers
Snap the module onto a 35 mm DIN rail, or onto a Power Rail section fed by a KFD2-EB2 power feed module and covered by UPR-03 end caps. Keep sensor cables away from relay wiring carrying 250 V AC. A 10 kilohm pair of resistors is shown in the connection diagram for dry-contact operation, so verify that the field contact is wetted correctly before blaming the unit.
Care and testing
Run a simulated overspeed and underspeed once a year, noting that the relays should change state within 200 ms. Check the green terminal blocks for discolouration, and keep the keypad window free of dust or condensate. If a unit is replaced, copy the programmed limits across, because they are stored in the device and not on the rail.
Use cases across the region
Typical Omani and GCC jobs include conveyor underspeed supervision in cement and aggregate plants, fan monitoring in utility cooling systems, and centrifuge or mixer drives in chemical batching where the sensor sits in a non-classified machine room.
Fault finding on a speed loop
When a monitor appears to trip without reason, the cause is usually outside the module. Measure the sensor supply on the terminals and compare it with the open-circuit and short-circuit values in the table. A fouled sensor face, a loose target wheel or a damaged cable shield each produce missing pulses that the monitor interprets as underspeed. Check the red line-fault LED first, because it separates a wiring problem from a genuine speed deviation, and then compare the displayed frequency with a hand tachometer or the control system reading. If the displayed value is stable and correct while the relay does not follow, the limit settings or the relay logic choice are the likely culprits.
Electrical noise from variable speed drives can also corrupt a high-frequency pulse train; screened twisted-pair cable earthed at one end and separation from motor cables normally resolves it.
Positioning within a plant architecture
In many plants the relays of such a monitor are wired to a safety PLC input card, with the second relay held for an independent hard-wired trip. Using one relay for the control system and the other for a local alarm lamp gives two independent indications from one sensor. The designer should record in the loop file which relay carries which limit and what state each takes on power loss.
Questions buyers ask about KFD2-DWB-1.D
What is the maximum input frequency of KFD2-DWB-1.D? The measurement range is 0.001 to 12000 Hz, noticeably higher than the 5 kHz of the Ex ia versions in the same product group.
Can KFD2-DWB-1.D use a three-wire sensor? Yes. Two-wire sensors connect to terminals 1+ and 3-, while three-wire sensors use terminals 1+, 2- and 3 according to the connection drawing.
Is KFD2-DWB-1.D an intrinsically safe barrier? No. It is described as a signal conditioner, and its hazardous-area marking is Ex nA nC IIC T4 Gc for Zone 2 use only.
What supply does KFD2-DWB-1.D need? It needs 20 to 30 V DC with about 100 mA, supplied on terminals 23+ and 24- or through the Power Rail.
How long can the start-up override of KFD2-DWB-1.D last? The override on input II can be programmed from 1 to 1000 seconds in steps of 1 s to suppress trips while the machine accelerates.
Documents and quotation
The manufacturer datasheet for KFD2-DWB-1.D accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. To request a quotation, send the RFQ with the exact part number KFD2-DWB-1.D, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-DWB-1.D Speed Monitor 12 kHz Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-DWB-1.D Speed Monitor 12 kHz
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum input frequency of KFD2-DWB-1.D?
The measurement range is 0.001 to 12000 Hz, noticeably higher than the 5 kHz of the Ex ia versions in the same product group.
02Can KFD2-DWB-1.D use a three-wire sensor?
Yes. Two-wire sensors connect to terminals 1+ and 3-, while three-wire sensors use terminals 1+, 2- and 3 according to the connection drawing.
03Is KFD2-DWB-1.D an intrinsically safe barrier?
No. It is described as a signal conditioner, and its hazardous-area marking is Ex nA nC IIC T4 Gc for Zone 2 use only.
04What supply does KFD2-DWB-1.D need?
It needs 20 to 30 V DC with about 100 mA, supplied on terminals 23+ and 24- or through the Power Rail.
05How long can the start-up override of KFD2-DWB-1.D last?
The override on input II can be programmed from 1 to 1000 seconds in steps of 1 s to suppress trips while the machine accelerates.