Pepperl+Fuchs KFD2-GUT-1.D Temperature Converter, 2 Relays
Description
KFD2-GUT-1.D temperature converter with two trip relays
The KFD2-GUT-1.D is a universal temperature signal conditioner. It takes the signal of a resistance thermometer, a thermocouple, a potentiometer or a voltage source, isolates it, and delivers a proportional 0/4 to 20 mA output plus two relay contacts that can be set as limit values. A display and keypad on the front allow local configuration, and the PACTware software is available for configuration from a PC.
Seven Star LLC supplies the KFD2-GUT-1.D in Oman and the GCC as an independent supplier in Muscat. This page explains the input options, the safety-related features and the points to confirm for a temperature-monitoring loop.
What KFD2-GUT-1.D stands for
The KFD2-GUT-1.D is a type designation of the Pepperl+Fuchs K-System, named in the datasheet as a temperature converter with trip values. It is a 1-channel signal conditioner with 24 V DC supply through the Power Rail. The housing is the wider C2 type, 40 mm, because it contains two relays in addition to the analog output.
The datasheet lists the function as a conditioner with galvanic isolation between field and control circuits, and shows up to SIL 2 under IEC/EN 61508 and IEC/EN 61511. As with all safety ratings, the figures are valid only when the device is used within the conditions given in the manufacturer safety documentation.
Technical specifications of the KFD2-GUT-1.D
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pepperl+Fuchs / KFD2-GUT-1.D |
| Function | Universal temperature converter with 2 trip relays, 1 channel |
| RTD inputs | Pt100, Pt500, Pt1000, Ni100, Ni1000; 2-, 3- or 4-wire; lead resistance max. 50 Ω |
| Thermocouples | Types B, E, J, K, L, N, R, S, T (IEC 584-1); internal and external cold junction compensation |
| Potentiometer | 0.8 … 20 kΩ, 2-, 3- or 5-wire |
| Voltage | 0 … 10 V, 2 … 10 V, 0 … 1 V, -100 … 100 mV |
| Analog output | 0 … 20 mA or 4 … 20 mA, load max. 650 Ω |
| Fault signalling | Downscale ≤ 3.6 mA, upscale ≥ 21 mA (NAMUR NE43); LEDs per NAMUR NE44 |
| Relay outputs | 2 x relay, 250 V AC / 2 A / cos φ ≥ 0.7; 40 V DC / 2 A |
| Accuracy | RTD max. 0.2 % of span; voltage 0.1 % of span; sampling rate approx. 700 ms |
| Supply | 20 … 30 V DC, approx. 100 mA; power dissipation ≤ 2 W |
| Functional safety | SIL 2 (IEC/EN 61508 / 61511) |
| Ambient temperature | -20 … 60 °C |
| Housing | Type C2, 40 x 119 x 115 mm, approx. 300 g, 35 mm DIN rail, IP20 |
How the KFD2-GUT-1.D converts temperature signals
For a resistance thermometer, the module applies a measuring current of about 400 µA and evaluates the resistance of the sensor in 2-, 3- or 4-wire connection. The 3- and 4-wire modes remove lead resistance errors, and the datasheet allows up to 50 Ω of lead resistance. For thermocouples, the module compensates the cold junction either internally, with the removable K-CJC terminal block available as an accessory, or externally. Sensor breakage is detected, and RTD short circuit is detected too.
The measured temperature is output as a 0 or 4 to 20 mA current. In a fault the output goes to the NAMUR NE43 downscale or upscale level, so the control system can distinguish a broken sensor from a valid measurement. The two relays work as limit contacts and can be configured for minimum or maximum alarms.
A redundant thermocouple input is listed as a feature on the datasheet, which supports duplicated measuring points on critical equipment such as bearings and furnaces.
Using the KFD2-GUT-1.D with related converters
The KFD2-GUT-1.D is a 40 mm module intended for safe-area sensors. For temperature signals from intrinsically safe sensors the K-System offers Ex temperature converters such as the KFD2-UT2-Ex2, and the 12.5 mm KCD2-UT2-1 is a slimmer universal converter without relays.
Together with the KFD2-EB2 power feed module and the UPR-03 rail, a row of KFD2-GUT-1.D modules forms a compact multi-point temperature interface in a control cabinet.
Selection and ordering checklist for the KFD2-GUT-1.D
- Define the sensor type: RTD, thermocouple, potentiometer or voltage
- For thermocouples, decide on internal cold junction (K-CJC terminal block) or external compensation
- Define the temperature span and the output range
- Define the alarm setpoints for the two relays
- Confirm the SIL requirement and available safety documentation
- Check ambient range -20 to 60 °C against the cabinet
Commissioning the KFD2-GUT-1.D
Wire the sensor to terminals 1 to 4 and 6 according to the sensor type, connect the supply, and configure the sensor type, span, damping and relay thresholds with the keypad or PACTware. Verify the NAMUR fault behaviour by disconnecting the sensor, and verify the relay logic with a simulator before connecting the control system.
If thermocouples are used with internal cold junction compensation, install the K-CJC terminal block on the field terminals and let the module reach thermal equilibrium before checking the reading. For maintenance, save the PACTware parameter file so that a replacement module can be configured identically.
Typical applications in Oman and the GCC
Temperature supervision of motor bearings, gearboxes, process lines, boilers and turbine auxiliaries is the typical home for this module. In Gulf installations, high ambient and radiant heat make accurate sensor-side compensation and fault detection valuable, and the combination of 4-20 mA output with two relay alarms removes the need for a separate temperature switch.
Temperature converters in the K-System range
From the manufacturer datasheets.
| Part number | Output | Width | Relays |
|---|---|---|---|
| KFD2-GUT-1.D | 4-20 mA | 40 mm | 2 |
| KCD2-UT2-1 | 4-20 mA, sink or source | 12.5 mm | None |
| KFD2-UT2-Ex2 | Ex temperature converter (separate datasheet) | See datasheet | See datasheet |
Information to send with an RFQ for the KFD2-GUT-1.D
Include the following with your enquiry.
- Sensor type and number of wires
- Required temperature range
- Relay setpoints and logic
- Quantity and delivery date
Documents and quotation
The manufacturer datasheet for the KFD2-GUT-1.D is attached on this page, so the electrical data, terminal assignment and ambient limits quoted above can be checked against the original document before an order is placed.
Seven Star LLC supplies Pepperl+Fuchs products in Oman and the GCC as an independent supplier in Muscat. Send the quantity, the signal types and the project delivery date, and we will confirm availability and lead time in a written quotation.
Other Models in the Pf Kfd2 D Series Range
Seven Star LLC supplies models from the Pf Kfd2 D Series range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-USC-1.D Signal Converter with Trip Value | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-GUT-1.D Temperature Converter, 2 Relays | Isolator & Barrier | You are viewing this model |
| Pepperl+Fuchs KFD2-UFC-1.D Frequency Converter with Trip Values | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-GUT-1.D Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-GUT-1.D Temperature Converter, 2
Answers from our engineering team on installation, compatibility and integration.
01Which temperature sensors does the KFD2-GUT-1.D accept?
RTD Pt100, Pt500, Pt1000, Ni100 and Ni1000 in 2-, 3- or 4-wire, thermocouple types B, E, J, K, L, N, R, S and T, potentiometers and voltage signals.
02How is cold junction compensation handled?
Both internal and external compensation are listed. The removable K-CJC terminal block is available as an accessory for internal compensation.
03How are sensor faults indicated?
Through LEDs according to NAMUR NE44, a collective error output and NAMUR NE43 output levels of 3.6 mA or below and 21 mA or above.
04How many relays does it have?
Two relay outputs, each 250 V AC / 2 A at cos phi 0.7 or 40 V DC / 2 A.
05How is it configured?
By the front keypad and display or with the PACTware configuration software through the programming socket.