Brand: Endress+Hauser (E & H)
Endress+Hauser FMR50 Free Space Radar Level Transmitter, 26 GHz
Description
Endress+Hauser FMR50 Micropilot Endress+Hauser FMR50 overview
The Endress+Hauser Micropilot Endress+Hauser FMR50 is a free space radar transmitter for continuous, non-contact level measurement of liquids, pastes and slurries. Its antenna is an encapsulated horn clad in PVDF or PP, so the wetted surface is plastic and the device suits many aggressive or sticky media where a metal antenna would need extra protection.
The FMR50 works in the K-band at about 26 GHz with statistically coded transmission pulses, which allows up to eight Micropilot transmitters to be installed in the same tank without disturbing one another. The maximum measuring range is 40 m, and the datasheet gives an accuracy of plus or minus 2 mm, which is enough for inventory control as well as process control on typical storage and process tanks.
Seven Star LLC lists the FMR50 for buyers in Oman and the GCC who need the exact model that is already installed or specified. Engineers often search by the model code, and the FMR50 is one of the products that plants reorder for replacement, expansion and maintenance work.
Key features of the FMR50
- Maximum measuring range of 40 m (131 ft) with accuracy of plus or minus 2 mm
- Process temperature from minus 40 to plus 130 degrees C and process pressure from minus 1 to plus 3 bar
- Multi-Echo Tracking for stable readings when product and process conditions change
- HistoROM data management that keeps the configuration for commissioning, service and diagnostics
- SIL2 according to IEC 61508, and SIL3 with homogeneous or heterogeneous redundancy
- Bluetooth wireless technology with the SmartBlue app for commissioning and maintenance
- Heartbeat Technology, easy proof test for SIL and WHG, and linearity protocols with 3 or 5 points on request
FMR50 technical specifications
| Parameter | Value |
|---|---|
| Measuring principle | Free space radar, K-band about 26 GHz |
| Application | Liquids, pastes and slurries |
| Antenna | Encapsulated horn antenna, PVDF or PP cladded |
| Maximum measuring range | 40 m (131 ft) |
| Accuracy | Plus or minus 2 mm |
| Process temperature | Minus 40 to plus 130 degrees C (minus 40 to plus 266 degrees F) |
| Process pressure | Minus 1 to plus 3 bar (minus 14.5 to plus 43.5 psi) |
| Output | 4 to 20 mA with HART, optional switch output on HART devices |
| Functional safety | SIL2 per IEC 61508, SIL3 with redundancy |
| Approvals listed | International explosion protection, WHG, marine approvals |
| Operation | Local display, Bluetooth with SmartBlue, optional remote display FHX50 |
The values above are taken from the manufacturer Technical Information for the FMR50. Exact limits depend on the selected version, material, process connection and approval, so confirm the order code against the datasheet before purchase.
Typical applications of the FMR50 in Oman and the GCC
Typical jobs include chemical day tanks, wastewater and sludge basins, process water and utility tanks, and storage of corrosive liquids where a plastic antenna is preferred. In Omani and GCC plants the FMR50 is often considered for desalination and water treatment tanks, chemical dosing stores in refineries and petrochemical sites, and utility tanks in power stations.
Across oil and gas, utilities, water and wastewater, and manufacturing plants in the region, the FMR50 is selected where the application matches the limits listed in the specifications table. Hot ambient conditions, dust and long cable runs are normal in the Gulf, so check the ambient temperature range and the housing protection against the site conditions.
Selection and compatibility notes for the FMR50
Because the FMR50 is limited to a process pressure of minus 1 to plus 3 bar, it is intended for atmospheric or low-pressure vessels. For higher pressures or for hot vapour, a device with a different antenna and a higher pressure rating from the same radar family is the better selection. Confirm the dielectric properties of the medium, the nozzle height and diameter, and the required approval before you request a quotation.
Installation and commissioning of the FMR50
Mount the antenna so that the beam is not blocked by internal fittings, and keep it clear of the tank wall and of filling streams. The datasheet describes free-space installation, stilling well and bypass options, and containers with heat insulation. Align the transmitter housing and display for easy reading, then commission using the menu or the SmartBlue app and use the envelope curve to confirm that the level echo is clean.
Always follow the Operating Instructions of the FMR50 and the local rules for electrical installation, especially in hazardous areas. Document the tag, configuration and as-found values at commissioning so that later service checks can be compared with them.
Maintenance of the FMR50
A scheduled inspection of the FMR50 should cover the wetted parts or sensing element for damage or build-up, the cable glands and seals for tightness, the housing cover and gasket, and the loop signal against a reference. Keep a record of the device serial number and order code, because they identify the exact version when you need a spare or replacement.
Related products and ordering notes for the FMR50
The FMR50 belongs to the Micropilot product line of the manufacturer. Neighbouring models in the same Technical Information share much of the documentation and accessories, so confirm which model the project needs. Accessories such as weather covers, mounting hardware and remote displays are specified by their own order codes.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify the item that the buyer wants to purchase.
When you prepare a purchase request for the FMR50, collect the full order code from the existing nameplate if you are replacing a unit, the tag number, the measuring range or probe length, the process connection, the electrical output and the hazardous-area certificate. Matching these details avoids mistakes with look-alike versions, and it lets the supplier confirm availability and lead time without delay. For spare or legacy requirements, the serial number printed on the nameplate helps identify the exact build.
FMR50 frequently asked questions in brief
What is the maximum measuring range of the FMR50? The datasheet states a maximum measuring range of 40 m (131 ft) for the FMR50, with accuracy of plus or minus 2 mm. The usable range in a real tank also depends on the medium and the installation. What process temperature and pressure does the FMR50 handle? The process temperature range is minus 40 to plus 130 degrees C and the process pressure range is minus 1 to plus 3 bar, according to the manufacturer Technical Information. What kind of antenna does the FMR50 use? It uses an encapsulated horn antenna with PVDF or PP cladding, which makes the wetted parts plastic and suitable for many corrosive liquids.
Documents and quotation
The manufacturer Technical Information for the FMR50 is available as a datasheet that you can download from this product page, and it lists the full ordering structure. To receive a quotation, send an RFQ with the part number FMR50, the quantity, the required version and options, and the delivery location. We reply with availability and lead time for your Oman or GCC project.
Datasheets & Documents
- Datasheet Endress+Hauser FMR50 Free Space Radar Level Transmitter, 26 GHz Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMR50 Free Space Radar Level
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum measuring range of the FMR50?
The datasheet states a maximum measuring range of 40 m (131 ft) for the FMR50, with accuracy of plus or minus 2 mm. The usable range in a real tank also depends on the medium and the installation.
02What process temperature and pressure does the FMR50 handle?
The process temperature range is minus 40 to plus 130 degrees C and the process pressure range is minus 1 to plus 3 bar, according to the manufacturer Technical Information.
03What kind of antenna does the FMR50 use?
It uses an encapsulated horn antenna with PVDF or PP cladding, which makes the wetted parts plastic and suitable for many corrosive liquids.
04Can the FMR50 be used in safety functions?
The datasheet lists SIL2 according to IEC 61508, and SIL3 when homogeneous or heterogeneous redundancy is used, with an easy proof test for SIL.
05How do I order the FMR50 from Seven Star LLC?
Send an RFQ with the part number FMR50, the quantity, the antenna and process connection, the output and housing, and the approvals you need. We reply with availability and a quotation.


















Reviews