Brand:

Yokogawa GX90XA-10-C1 10-Channel 4-20 mA Analog Input Module

Description

Yokogawa GX90XA-10-C1 overview

The Yokogawa GX90XA-10-C1 is the 10-channel DC current input module in the Yokogawa GX90 series. It reads 0 to 20 mA and 4 to 20 mA standard signals directly through a built-in shunt resistor, so transmitters and loop-powered instruments can be wired to the recorder without external resistors.

Reading the suffix table, GX90XA is the analog input module, -10 is 10 channels and -C1 is the current (mA) input scanner type with isolation between channels; the fixed N, the terminal form (-3 for M3 screw or -C for clamp) and the area code N complete the order string. It plugs into the GX and GP paperless recorders, the expandable I/O unit and the GM main and sub units.

This page describes the Yokogawa GX90XA-10-C1 as published in the manufacturer’s general specification GS 04L53B01, written in our own words for buyers who need to identify the exact part. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We supply against the part number you provide and do not substitute without your written agreement.

Key features of the GX90XA-10-C1

  • Ten DC current channels with a built-in shunt resistor of about 250 ohm, so no external shunt is needed for 4-20 mA signals.
  • Ranges 0-20 mA and 4-20 mA, with a usable range of 3.200 to 20.800 mA for the 4-20 mA standard signal.
  • Isolation between channels, which avoids ground-loop interaction between separately powered transmitters.
  • Burnout detection for standard signals with a judgment value set as a percentage of span (lower limit minus 20 to minus 5 percent, upper limit 105 to 120 percent).
  • Operation modes: 10-channel normal mode, or 2-channel low-noise mode.
  • Removable input terminal block for efficient wiring and module swapping.

GX90XA-10-C1 technical specifications

Item Specification
Model GX90XA analog input module
Order code (this page) GX90XA-10-C1 (10 channels, current input, scanner type)
Channels 10 (or 2 in low-noise mode)
Input range 0-20 mA and 4-20 mA (3.200 to 20.800 mA)
Accuracy (0-20 mA) plus or minus (0.3 percent of reading + 5 microamp) with integration time 16.7 ms or more
Input resistance 250 ohm (249.5 ohm typical) for DC mA
Allowable input current 24 mA (50/60 Hz, peak value including signal)
Isolation Between channels
Terminal form (suffix) -3 M3 screw terminal, or -C clamp terminal
Compatible hosts GX10, GX20, GP10, GP20, expandable I/O, GM main unit, GM sub unit

The values above are taken from the manufacturer’s general specification for the GX90 I/O modules. Treat the document as the controlling reference and confirm every figure against the latest revision before final design, because the manufacturer may change specifications without notice.

Typical applications in oil and gas, utilities, water and manufacturing

Analog input modules are used where a recorder or data acquisition unit must be extended or repaired: adding channels on a boiler or furnace temperature survey, replacing a failed module in a water-treatment or power-plant logging panel, or standardising spares across several GX, GP and GM units in Oman and the GCC.

A buyer who already has the GX90XA-10-C1 installed usually wants the same suffix code again, which keeps panel cutouts, terminal layouts, spare stocks and documentation unchanged. That is the main reason this exact part number is searched for rather than a generic description.

Selection and compatibility notes for the GX90XA-10-C1

  • Use -C1 where all ten channels are 4-20 mA; use -U2 where thermocouples, RTDs or volts are also needed.
  • Choose -3 (M3 screw) or -C (clamp) terminals consistent with existing wiring.
  • Check the host’s module capacity (up to 3 modules in the GX10, up to 10 in the GX20).
  • For loop power, supply the 24 V DC separately; the module is a measuring input, not a loop power source.

The general specification lists calibration certificate and test certificate (QIC) options for each module.

Installation and commissioning

Switch the host off before inserting or removing a module, seat the module in a free slot, and wire each channel to the removable terminal block with the cable type recommended for thermocouples or RTDs. Assign the signal type, range and scale for each channel in the host, choose the measurement interval and noise-reduction mode, and verify the channels with a calibrator. Where a shunt resistor is used, fit the correct value for the terminal style in use.

Before energising a GX90XA-10-C1 in a hazardous or critical service, confirm that the selected variant, enclosure rating and any approvals you require are covered by the order string and by your site rules.

Maintenance and spare parts

Modules have no user-serviceable parts. Check terminal tightness, keep the terminal blocks clean, and verify the channels periodically against a calibrator. When a module is replaced, note that each analog input module carries its own calibration certificate and test certificate options, and retain the order string and terminal form so the spare matches the original.

Related products and ordering notes

The GX90XA-10-C1 belongs to the GX90 I/O modules group. Related family members, modules, software and accessories are listed in the same general specification, and we can quote them together with the GX90XA-10-C1 when you need a complete panel or loop. Because many Yokogawa instruments are specified by long suffix strings, always quote the complete order code, the option codes, the quantity and the destination. If your installed unit is an older revision, send a nameplate photograph or the exact code printed on it so that compatibility can be checked before any quotation is issued.

Frequently asked questions about the GX90XA-10-C1

  • Does GX90XA-10-C1 need an external shunt resistor? No. The current input type has a built-in shunt (about 250 ohm), so 4-20 mA signals connect directly.
  • How many channels does GX90XA-10-C1 have? It has ten channels in normal mode; a two-channel low-noise mode can be selected for measurements less affected by supply-frequency noise.
  • What accuracy is stated? The general specification states plus or minus (0.3 percent of reading + 5 microamp) for 0-20 mA with an integration time of 16.7 ms or more.
  • Which recorders accept the GX90XA-10-C1? The GX and GP paperless recorders, the expandable I/O unit and the GM data acquisition main and sub units.
  • What is needed for an RFQ? Send the string GX90XA-10-C1 with the terminal form, the quantity and the host model, plus your delivery location in Oman or the GCC.

Documents and quotation

The manufacturer’s datasheet for the GX90XA-10-C1 is available on this page for download and lists the model and suffix codes, specifications and dimensions in full. To request a quotation, send the RFQ with the part number GX90XA-10-C1, the quantity, any option codes and the delivery destination in Oman or the GCC. Our team will confirm availability, lead time and commercial terms for the GX90XA-10-C1 by return.

Other Models in the GX90 I/O Modules Range

Seven Star LLC supplies models from the GX90 I/O Modules range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa GX90XA-10-U2 10-Channel Universal Analog Input ModulePLC & I/O CardsView details
Yokogawa GX90XA-10-C1 10-Channel 4-20 mA Analog Input ModulePLC & I/O CardsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa GX90XA-10-C1 10-Channel 4-20 mA Analog Input Module Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa GX90XA-10-C1 10-Channel 4-20 mA Analog

Answers from our engineering team on installation, compatibility and integration.

01Does GX90XA-10-C1 need an external shunt resistor?
No. The current input type has a built-in shunt (about 250 ohm), so 4-20 mA signals connect directly.
02How many channels does GX90XA-10-C1 have?
It has ten channels in normal mode; a two-channel low-noise mode can be selected for measurements less affected by supply-frequency noise.
03What accuracy is stated?
The general specification states plus or minus (0.3 percent of reading + 5 microamp) for 0-20 mA with an integration time of 16.7 ms or more.
04Which recorders accept the GX90XA-10-C1?
The GX and GP paperless recorders, the expandable I/O unit and the GM data acquisition main and sub units.
05What is needed for an RFQ?
Send the string GX90XA-10-C1 with the terminal form, the quantity and the host model, plus your delivery location in Oman or the GCC.