- Automation & ControlView all 2,668 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: SERVOMEX
Servomex 204629 Fuse F101 2 A for Oxy 1900 (100-120 V)
Description
Servomex 204629 overview: 2 A fuse for supply fuse position F101 for the Oxy 1900 digital analyser
The Servomex 204629 is the F101 supply fuse for 1900 Digital analysers operated from a 100 to 120 V supply. The manual lists it as a 2 A fuse for 100 to 120 V operation, and the electrical data in the manual gives the internal fuse rating as T 2.0 A H 250 V for that supply range. It protects the analyser from over-current on the incoming mains side.
The image on this page shows the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser) that this item belongs to, so that buyers can recognise the equipment family; it is not a close-up of the 2 A fuse for supply fuse position F101 itself. Every detail on this page is taken from the manufacturer documentation for that equipment, and where a value is not stated there, we have left it out rather than guess.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Servomex 204629 so that maintenance and procurement teams can quote the exact number that appears in the manufacturer manual, which matters because instrument spares are rarely interchangeable by description alone.
Key features of 204629
- Exact manufacturer part number 204629, taken from the documented spares or parts list of the analyser.
- Item: 2 A fuse for supply fuse position F101.
- Intended equipment: SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser).
- The fuse rating depends on the supply voltage setting of the analyser: 2 A for 100 to 120 V operation (204629) and 1 A for 220 to 240 V operation (2531-2630).
- Supplied against a quotation request that confirms the analyser model, serial number and quantity.
Technical specifications for 204629
The first table records the data for the part itself, as given in the manufacturer documentation. The second table records the main data of the host equipment, which helps confirm that the part suits the installation. No pricing is shown on this page, and values not published in the documentation are not included.
Part data
| Item | Value |
|---|---|
| Part number | 204629 |
| Description | Fuse F101, 2 A, for 100 to 120 V operation |
| Rating per manual | T 2.0 A H 250 V |
| Fits | 1900 Digital O2 Gas Analyser |
Host equipment data
| Item | Value |
|---|---|
| Analyser family | SERVOTOUGH Oxy 1900, 1900 Digital O2 Gas Analyser |
| Analyser dimensions (H x W x D) | 235 x 448 x 229 mm |
| Analyser mass | 26 kg |
| Sample flow, standard inlet/outlet T piece | 50 to 250 ml/min |
| Sample flow, high flow bypass T piece | 50 to 70 l/h (60 l/h nominal) |
| Ambient temperature, operation | -10 to 50 degrees C |
| Ingress protection | IP65 |
| Supply | 100 to 120 V a.c. or 220 to 240 V a.c., 50 to 60 Hz, maximum 50 VA |
Typical applications in oil and gas, utilities, water and manufacturing
The 1900 Digital analyser measures oxygen in clean, non-corrosive, oil-free sample gas and is housed for hazardous-area installation, so it is typically found on inerting and blanketing lines, nitrogen generation and purity checks, solvent and chemical plant vapour spaces and similar duties. In Oman and the wider GCC that translates into refineries, gas processing trains, petrochemical units, LNG and storage terminals, plus industrial gas and manufacturing sites where a few percent of oxygen decides whether a line is safe to run.
Gulf conditions add their own demands: high ambient temperature, fine desert dust and coastal humidity all age seals, filters and electronics faster than in temperate climates. A planned stock of spares such as 204629 therefore pays back quickly, because an analyser that is waiting for a part can hold up a start-up, a safety check or an emissions report.
Selection and compatibility notes
The fuse rating depends on the supply voltage setting of the analyser: 2 A for 100 to 120 V operation (204629) and 1 A for 220 to 240 V operation (2531-2630). Never fit a different rating from the one the manual lists for your supply voltage. Check the supply label before ordering.
The manual for the 1900 Digital analyser states that the unit is not suitable for oxygen-enriched sample gases and that sample gas must be clean, non-corrosive, free from oil and condensate and with particulates smaller than 3 microns, which is exactly why the consumable parts at the sample inlet matter. The same manual warns that spares other than those it specifies can damage the analyser and invalidate its certification, so confirm the analyser model and transducer type before ordering.
When you send an enquiry for 204629, include the analyser model, the serial number or order code, the supply voltage if relevant, and a photograph of the nameplate. That information lets us confirm the match against the manufacturer documentation before a quotation is issued.
Installation and commissioning of 204629
To replace the fuse, isolate and lock out the electrical supply, remove the cover as described in the manual, take out fuse F101 and test continuity across it. If there is no continuity, the fuse has failed and a new fuse of the correct type is fitted. The manual advises that if a new fuse fails immediately there may be an underlying fault that must be investigated before power is restored.
As with any work on process analysers, follow the site permit-to-work system, isolate sample and electrical supplies, and use only the procedures in the manufacturer manual. After fitting 204629, return the analyser to service in the order the manual describes and confirm the reading with a suitable reference gas before relying on the output for control or alarms.
Maintenance and service life
Keep a small number of 204629 fuses in the electrical spares store of any site with 110 V supplies. A fuse that has failed more than once should be treated as a symptom, not a consumable: inspect cabling and supply quality first.
Keep a simple maintenance log for each analyser listing the date, the action and the part number used. When 204629 has been changed, a short note makes it easy to plan the next replacement and gives the manufacturer or an engineer useful history if a fault returns.
Related products and ordering notes
Other items from the same manual that are often ordered with 204629 include 2377-3862 (20 micron stainless steel inlet filter), 2323-7803 (Viton inlet filter O-ring), 2323-7928 (Chemraz inlet filter O-ring), 2531-2630 (1 A fuse for supply fuse position F101), 2344-2054 (stainless steel adaptor for 1/4 inch outside diameter tube), 2346-3073 (stainless steel adaptor for 6 mm outside diameter tube). Each is a separate part number and is quoted separately. Combining them in one enquiry avoids repeated shipments and shortens the shutdown window.
Many of these numbers belong to older analyser generations. If the manufacturer has superseded a part, we will tell you only if the manufacturer documentation names the replacement. Otherwise we will confirm availability and lead time before you commit to an order.
Frequently asked questions
The questions below summarise what buyers most often ask about 204629.
What is 204629? 204629 is the manufacturer part number for the 2 A fuse for supply fuse position F101 used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
Which equipment does 204629 fit? It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
Can Seven Star LLC supply 204629 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
Is a datasheet or manual available for 204629? The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
What details should I send with my RFQ for 204629? Send the part number 204629, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.
Documents and quotation
The official Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (01910001A) is attached to this page as a PDF. The Spares chapter (section 10, manual page 65) lists part 204629 as fuse F101, rated 2 A, for analysers operated from a 100–120 V supply. Send us the part number 204629 with the model and serial number of your analyser and we will confirm compatibility and lead time in a written quotation.
Other Models in the Servomex 1900 Range
Seven Star LLC supplies models from the Servomex 1900 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex 2377-3862 Inlet Filter 20 um SS for Oxy 1900 | Gas Analyzer Systems | View details |
| Servomex 2323-7803 Viton O-Ring for Oxy 1900 Inlet Filter | Gas Analyzer Systems | View details |
| Servomex 204629 Fuse F101 2 A for Oxy 1900 (100-120 V) | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex 204629 Fuse F101 2 A for Oxy 1900 (100-120
Answers from our engineering team on installation, compatibility and integration.
01What is 204629?
204629 is the manufacturer part number for the 2 A fuse for supply fuse position F101 used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
02Which equipment does 204629 fit?
It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
03Can Seven Star LLC supply 204629 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
04Is a datasheet or manual available for 204629?
The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
05What details should I send with my RFQ for 204629?
Send the part number 204629, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.


















Reviews
There are no reviews yet.