Servomex 2377-3862 overview: 20 micron stainless steel inlet filter for the Oxy 1900 digital analyser

The Servomex 2377-3862 is the replacement sample inlet filter for the 1900 Digital oxygen analyser. The manual describes it as a 20 micron stainless steel inlet filter, and it sits in the sample gas inlet where it stops particulate matter before gas reaches the oxygen transducer. Because the transducer is a precision paramagnetic element, a blocked or missing filter is one of the most common causes of drift, slow response and avoidable service visits.

The image on this page shows the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser) that this item belongs to, so that buyers can recognise the equipment family; it is not a close-up of the 20 micron stainless steel inlet filter itself. Every detail on this page is taken from the manufacturer documentation for that equipment, and where a value is not stated there, we have left it out rather than guess.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Servomex 2377-3862 so that maintenance and procurement teams can quote the exact number that appears in the manufacturer manual, which matters because instrument spares are rarely interchangeable by description alone.

Key features of 2377-3862

  • Exact manufacturer part number 2377-3862, taken from the documented spares or parts list of the analyser.
  • Item: 20 micron stainless steel inlet filter.
  • Intended equipment: SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser).
  • Order 2377-3862 together with the correct inlet filter O-ring: the manual lists a Viton O-ring for analysers with a standard oxygen transducer and a Chemraz O-ring for analysers with a solvent-resistant transducer.
  • Supplied against a quotation request that confirms the analyser model, serial number and quantity.

Technical specifications for 2377-3862

The first table records the data for the part itself, as given in the manufacturer documentation. The second table records the main data of the host equipment, which helps confirm that the part suits the installation. No pricing is shown on this page, and values not published in the documentation are not included.

Part data

Item Value
Part number 2377-3862
Description Inlet filter, 20 micron, stainless steel
Fits 1900 Digital O2 Gas Analyser
Pair with O-ring 2323-7803 (Viton) or 2323-7928 (Chemraz)

Host equipment data

Item Value
Analyser family SERVOTOUGH Oxy 1900, 1900 Digital O2 Gas Analyser
Analyser dimensions (H x W x D) 235 x 448 x 229 mm
Analyser mass 26 kg
Sample flow, standard inlet/outlet T piece 50 to 250 ml/min
Sample flow, high flow bypass T piece 50 to 70 l/h (60 l/h nominal)
Ambient temperature, operation -10 to 50 degrees C
Ingress protection IP65
Supply 100 to 120 V a.c. or 220 to 240 V a.c., 50 to 60 Hz, maximum 50 VA

Typical applications in oil and gas, utilities, water and manufacturing

The 1900 Digital analyser measures oxygen in clean, non-corrosive, oil-free sample gas and is housed for hazardous-area installation, so it is typically found on inerting and blanketing lines, nitrogen generation and purity checks, solvent and chemical plant vapour spaces and similar duties. In Oman and the wider GCC that translates into refineries, gas processing trains, petrochemical units, LNG and storage terminals, plus industrial gas and manufacturing sites where a few percent of oxygen decides whether a line is safe to run.

Gulf conditions add their own demands: high ambient temperature, fine desert dust and coastal humidity all age seals, filters and electronics faster than in temperate climates. A planned stock of spares such as 2377-3862 therefore pays back quickly, because an analyser that is waiting for a part can hold up a start-up, a safety check or an emissions report.

Selection and compatibility notes

Order 2377-3862 together with the correct inlet filter O-ring: the manual lists a Viton O-ring for analysers with a standard oxygen transducer and a Chemraz O-ring for analysers with a solvent-resistant transducer. The filter itself is the same part number in the spares table, but the O-ring choice depends on the transducer fitted, so confirm this on the analyser label or order record.

The manual for the 1900 Digital analyser states that the unit is not suitable for oxygen-enriched sample gases and that sample gas must be clean, non-corrosive, free from oil and condensate and with particulates smaller than 3 microns, which is exactly why the consumable parts at the sample inlet matter. The same manual warns that spares other than those it specifies can damage the analyser and invalidate its certification, so confirm the analyser model and transducer type before ordering.

When you send an enquiry for 2377-3862, include the analyser model, the serial number or order code, the supply voltage if relevant, and a photograph of the nameplate. That information lets us confirm the match against the manufacturer documentation before a quotation is issued.

Installation and commissioning of 2377-3862

Replacing the filter means isolating the sample gas, switching off and locking out the supply, opening the hinged sample and control compartment door with the 5 mm hexagonal key, disconnecting the transducer inlet and outlet pipes, removing the bulkhead and fitting the new O-ring and 2377-3862 filter into the sample gas inlet. The manual specifically warns not to open the door if an explosive atmosphere may be present.

As with any work on process analysers, follow the site permit-to-work system, isolate sample and electrical supplies, and use only the procedures in the manufacturer manual. After fitting 2377-3862, return the analyser to service in the order the manual describes and confirm the reading with a suitable reference gas before relying on the output for control or alarms.

Maintenance and service life

On clean, dry gas applications the manual says the inlet filter needs inspecting only every 3 months, and more often on other applications. It recommends keeping a stock of inlet filters. It also cautions that if the sample contains particulates the analyser must never be operated with the filter removed, since particulates will seriously damage it.

Keep a simple maintenance log for each analyser listing the date, the action and the part number used. When 2377-3862 has been changed, a short note makes it easy to plan the next replacement and gives the manufacturer or an engineer useful history if a fault returns.

Related products and ordering notes

Other items from the same manual that are often ordered with 2377-3862 include 2323-7803 (Viton inlet filter O-ring), 2323-7928 (Chemraz inlet filter O-ring), 204629 (2 A fuse for supply fuse position F101), 2531-2630 (1 A fuse for supply fuse position F101), 2344-2054 (stainless steel adaptor for 1/4 inch outside diameter tube), 2346-3073 (stainless steel adaptor for 6 mm outside diameter tube). Each is a separate part number and is quoted separately. Combining them in one enquiry avoids repeated shipments and shortens the shutdown window.

Many of these numbers belong to older analyser generations. If the manufacturer has superseded a part, we will tell you only if the manufacturer documentation names the replacement. Otherwise we will confirm availability and lead time before you commit to an order.

Frequently asked questions

The questions below summarise what buyers most often ask about 2377-3862.

What is 2377-3862? 2377-3862 is the manufacturer part number for the 20 micron stainless steel inlet filter used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.

Which equipment does 2377-3862 fit? It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.

Can Seven Star LLC supply 2377-3862 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.

Is a datasheet or manual available for 2377-3862? The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.

What details should I send with my RFQ for 2377-3862? Send the part number 2377-3862, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.

Documents and quotation

The official Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (01910001A) is attached to this page as a PDF. The Spares chapter (section 10, manual page 65) lists part 2377-3862 as the 20 µm stainless steel inlet filter, and section 7.2 describes how to replace it, which is why Servomex recommends keeping a stock of these filters on site. Send us the part number 2377-3862 with the model and serial number of your analyser and we will confirm compatibility and lead time in a written quotation.

Datasheets & Documents
  • PDF Datasheet Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the Servomex 2377-3862 Inlet Filter 20 um SS for Oxy

Answers from our engineering team on installation, compatibility and integration.

01What is 2377-3862?
2377-3862 is the manufacturer part number for the 20 micron stainless steel inlet filter used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
02Which equipment does 2377-3862 fit?
It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
03Can Seven Star LLC supply 2377-3862 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
04Is a datasheet or manual available for 2377-3862?
The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
05What details should I send with my RFQ for 2377-3862?
Send the part number 2377-3862, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.