Brand:

AMETEK 563075938 2850 Moisture Analyzer Sensor Cell Standard

Description

AMETEK 563075938 overview

AMETEK 563075938 is the standard sensor cell for the AMETEK 2850 moisture analyzer. AMETEK lists it under 2850 sensor (cell), standard, with the description cell 2850 HT TRTD standard calibration. The 2850 is the trace moisture analyzer used to monitor process desiccant dryers, instrument air dryers and air separators, and for industrial gas production and quality assurance. The sensor cell is the wearing element of this analyzer, and buyers with an installed 2850 base ask for the number directly.

The AMETEK 2850 is a trace moisture analyzer for process desiccant dryers, instrument air dryers, air separators and industrial gas production. The datasheet describes ultrafast response (63 percent of a steady state reading in under five minutes), accuracy of plus or minus 5 percent from 1 to 100 ppmv, and an internal NIST-traceable moisture generator for verification.

Key features of 563075938

  • Standard sensor cell for the 2850 moisture analyzer
  • Described as HT TRTD standard calibration in the AMETEK listing
  • Supports the 2850 operating range 0.1 to 1000 ppmv
  • Calibrated range 1 to 100 ppmv with trend indication outside
  • Photo shows the cell on its circuit board with orange fittings
  • Replaced as a unit

563075938 technical specifications

Item Detail
Part number 563075938
Description Cell 2850 HT TRTD standard calibration
Category (AMETEK) 2850 sensor (cell), standard
Operating range (datasheet) 0.1 to 1000 ppmv; calibrated 1 to 100 ppmv
Accuracy (datasheet) Plus or minus 0.05 ppmv or 5 percent of reading, whichever is greater
Response (datasheet) 63 percent of step change in under five minutes
Calibrated range 1 to 100 ppmv with trend indication
Accuracy Plus or minus 0.05 ppmv or 5 percent of reading
Response 63 percent in under five minutes
Outputs Two programmable 4-20 mA, RS-485 serial port
Inlet pressure 1 to 6.89 bar (15 to 100 psig)
Power 85 to 265 volts, 47 to 63 Hz
Dimensions 432 x 132 x 381 mm bench version

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 563075938. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet names industrial gas production and quality assurance, cryogenic air separation and process dryers, with markets in air separation, petrochemical, chemical and refinery. Air separation and industrial gas plants in the GCC use trace moisture analysis to protect cryogenic equipment and to certify product gas.

Where 563075938 is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 563075938

Confirm the analyzer is a 2850 and not a 5000 or 3050 before ordering a sensor cell, because the cells are different parts.

Part number 563075938 is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Follow the 2850 user manual for sensor replacement. Switch the analyzer to a safe state, shut off sample flow, disconnect the sensor fittings and electrical connector, install 563075938 and restore the connections, then run the internal verification with the NIST-traceable moisture generator which the datasheet describes. The alarm contact alerts the operator if verification fails.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 563075938. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

Compare verification results over time. The datasheet states that the 2850 reaches 63 percent of a steady state reading in under five minutes, so a visibly slower response is an early sign of an ageing cell.

Related products and ordering notes

Compare the 5000 sensor cell 563075928, which is a different cell for a different analyzer.

For a spare parts plan, list 563075938 against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Operators in Oman and the Gulf work in high ambient temperatures, dust and humidity, and sites often plan turnarounds months ahead, so confirming the exact number of every spare before the shutdown window is valuable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle enquiries for hard-to-find and legacy numbers directly.

Selection Notes for the AMETEK 563075938

When comparing the AMETEK 563075938 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment it will sit in, and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any of these points are uncertain, send a photo of the nameplate and a short description of the application; our team will compare it with the gas analyzer accessories range and confirm the correct order code before you commit to a purchase.

Frequently asked questions about 563075938

  • What is AMETEK 563075938? It is the standard sensor cell for the AMETEK 2850 moisture analyzer.
  • What range does the 2850 cover? The datasheet gives an operating range of 0.1 to 1000 ppmv with factory calibration from 1 to 100 ppmv.
  • Does the 2850 verify itself? Yes. The datasheet describes an internal NIST-traceable moisture generator for verification on a schedule or on demand.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 563075938, send the RFQ with the part number 563075938, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK 2850 Moisture Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 563075938 2850 Moisture Analyzer Sensor Cell

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 563075938?
It is the standard sensor cell for the AMETEK 2850 moisture analyzer.
02What range does the 2850 cover?
The datasheet gives an operating range of 0.1 to 1000 ppmv with factory calibration from 1 to 100 ppmv.
03Does the 2850 verify itself?
Yes. The datasheet describes an internal NIST-traceable moisture generator for verification on a schedule or on demand.
04Is 563075938 the same as the 5000 cell?
No. The 5000 analyzer uses the standard timing cell 563075928, a different part.
05How do I request a quotation for 563075938?