Brand:

AMETEK 305122902S 3050 H2S Treated Calibrated QCM Sensor

Description

AMETEK 305122902S overview

AMETEK 305122902S is the H2S treated, calibrated QCM sensor field replaceable unit for the AMETEK 3050 moisture analyzer. The 3050 datasheet states that the analyzer can operate in environments with up to 30 percent hydrogen sulfide, and the H2S treated sensor is the version intended for such sour gas service. The AMETEK listing calls it a 3050 sensor (cell), H2S treated, and notes a temporary long lead time. Sour gas processing is common in the Gulf, so this exact number is the one gas plants quote.

The AMETEK 3050 series uses quartz crystal microbalance (QCM) technology with online verification for ppmv and sub-ppmv moisture in industrial gases. The datasheet describes a NIST-traceable dual-concentration moisture generator for scheduled or on-demand verification, a consumable service life exceeding three years, no routine factory calibration, and operation with up to 30 percent hydrogen sulfide or 100 percent carbon dioxide.

Key features of 305122902S

  • H2S treated calibrated QCM sensor for sour gas service
  • 3050 field replaceable unit
  • 3050 series operates in up to 30 percent H2S according to the datasheet
  • Also able to handle 100 percent CO2 environments (datasheet)
  • Calibrated before supply
  • Temporary long lead time noted in the AMETEK listing

305122902S technical specifications

Item Detail
Part number 305122902S
Description Sensor QCM H2S treated, 3050, calibrated, FRU
Category (AMETEK) 3050 Sensor (Cell), H2S treated
Sour gas capability (datasheet) Up to 30 percent hydrogen sulfide, 100 percent carbon dioxide
Ambient (datasheet) Up to 50 C, extended to 60 C with the high temperature option
Technology Quartz crystal microbalance
Technology (datasheet) Quartz crystal microbalance (QCM)
Ranges OLV 0.1-2500 ppmv; SLR 0.1-100 ppmv; DO 0.02-100 ppmv; TE 0.01-100 ppmv
Accuracy Plus or minus 0.1 ppmv or 10 percent (OLV), tighter on SLR, DO and TE
Online verification Internal NIST-traceable moisture source
Communications RS485 Modbus RTU, Ethernet, USB
Analog outputs Two isolated 16-bit 4-20 mA
Ambient Up to 50 degrees C, 60 degrees C with high temperature option
Certification IECEx/ATEX Zone 1

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 305122902S. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet lists natural gas quality in pipelines and custody transfer stations, natural gas processing and dehydration, feedstock gas quality, molecular sieve dryer efficiency, cryo-recovery turbo expander inlet and outlet, and hydrogen recycle gas in continuous catalytic reactors. Oman and GCC gas processing plants and pipeline operators use moisture analyzers to protect against hydrate formation and to prove gas quality.

Where 305122902S is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 305122902S

Confirm the analyzer model (OLV, SLR, DO or TE), the calibrated range and the gas service (standard, CO2 or sour) before ordering the consumable, and quote the analyzer serial number where possible.

Part number 305122902S is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Follow the sensor replacement instructions of the 3050 user manual. Isolate sample, handle the sensor by its board, fit the new unit and reconnect the cable, then run the internal verification from the analyzer menu. For sour gas service follow the site hazard procedures for hydrogen sulfide before opening any sample path component.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 305122902S. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

Use the on-demand verification to confirm that the sensor tracks the moisture generator levels. The datasheet adds that the integrated display gives access to measurement data, alarms and configuration without a hot-work permit.

Related products and ordering notes

305121901S is the general 0-100 ppm sensor, 11700-13-3 is the sour gas FRU for the 0-2500 ppm OLV version, and 305448902S is the 2 micron filter.

For a spare parts plan, list 305122902S against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Operators in Oman and the Gulf work in high ambient temperatures, dust and humidity, and sites often plan turnarounds months ahead, so confirming the exact number of every spare before the shutdown window is valuable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle enquiries for hard-to-find and legacy numbers directly.

Frequently asked questions about 305122902S

  • What is AMETEK 305122902S? It is the H2S treated calibrated QCM sensor for the AMETEK 3050 moisture analyzer, supplied as a field replaceable unit.
  • How much hydrogen sulfide can the 3050 handle? The datasheet says the 3050 series can operate with up to 30 percent hydrogen sulfide or 100 percent carbon dioxide.
  • Is the sensor calibrated? Yes. The AMETEK listing names it a calibrated FRU.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 305122902S, send the RFQ with the part number 305122902S, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK 3050 Series Moisture Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 305122902S 3050 H2S Treated Calibrated QCM

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 305122902S?
It is the H2S treated calibrated QCM sensor for the AMETEK 3050 moisture analyzer, supplied as a field replaceable unit.
02How much hydrogen sulfide can the 3050 handle?
The datasheet says the 3050 series can operate with up to 30 percent hydrogen sulfide or 100 percent carbon dioxide.
03Is the sensor calibrated?
Yes. The AMETEK listing names it a calibrated FRU.
04Is there a lead time note?
The AMETEK listing mentions a temporary long lead time, so request availability early.
05How do I request a quotation for 305122902S?
Send the part number 305122902S, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.