Brand:

Yokogawa EJXC81A Absolute Pressure Diaphragm Seal System

Description

Yokogawa EJXC81A Absolute Pressure Diaphragm Seal System: overview

The Yokogawa EJXC81A is the absolute pressure version of the Yokogawa diaphragm seal system. It couples an EJX310A absolute pressure transmitter to a single diaphragm seal, so absolute or vacuum pressure can be measured on hot, corrosive or viscous media.

Seven Star LLC lists the Yokogawa EJXC81A for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJXC81A

  • EJXC81A isolates the transmitter from the process with a diaphragm seal filled with a defined fill fluid.
  • Suitable for hot, cold, corrosive, viscous, toxic or clogging fluids where impulse lines are impractical.
  • Flushing connection rings allow venting and draining of the seal where the datasheet permits.
  • Segment signal characterizer built into the transmitter for non-linear signals.
  • Several seal styles are described in the datasheet, so the EJXC81A can follow the flange or hygienic standard of the plant.
  • Transmitter section carries its own certifications, with the seal system defined by the model code.

EJXC81A technical specifications

One flanged seal is mounted on the high pressure side. Flush and extended flanged seals, as well as inner diaphragm seals in adapter and flange connection forms, are listed in the datasheet. The high temperature and high vacuum capability starts at 0.013 kPa abs.

Response time is 200 ms, and a segment signal characterizer allows non-linear signals such as tank geometry to be handled in the transmitter.

The EJAC81E variant is built on the EJA310E and covered by the same datasheet.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Absolute pressure diaphragm seal system with a single flanged seal
Applicable transmitter EJX310A (also EJA310E as EJAC81E)
Flush flanged seal sizes 1 1/2 inch (40 mm), 2 inch (50 mm), 3 inch (80 mm)
Extended flanged seal sizes 3 inch (80 mm), 4 inch (100 mm)
Inner diaphragm seal sizes 1/2 inch (15 mm), 3/4 inch (20 mm), 1 inch (25 mm); adapter and flange connection types
Response time 200 ms
Vacuum capability High temperature and high vacuum use from 0.013 kPa abs
Signal characterizer Segment signal characterizer

Typical applications in Oman and the GCC

  • Oil and gas. Refineries and gas plants apply the EJXC81A on vacuum distillation columns, evaporators, crystallizers, reactors with hot or aggressive media and vacuum drying lines, where a direct impulse line would plug, freeze or corrode.
  • Utilities and power. In power plants a seal system such as the EJXC81A isolates the transmitter from hot or aggressive media, which keeps the electronics in a more benign environment.
  • Water and desalination. Chemical dosing, brine and sludge services in water treatment can use a EJXC81A so that the process fluid never enters the sensing body.
  • Manufacturing and process. Chemical, food and pharmaceutical process lines use the EJXC81A on viscous, crystallizing or hygienic media, with the seal type chosen to match the connection standard of the plant.

Selection and compatibility notes

A EJXC81A is selected by the combination of transmitter, seal type, seal size, fill fluid and capillary length. The datasheet lists the process connection sizes and the transmitters that can be combined, and a separate model code table describes the options. Fill fluid decides the allowed process temperature and working pressure, so it should be chosen with the lowest and highest process temperature in mind.

Capillary routing matters for accuracy. Long capillaries and ambient temperature swings add error, which is why the compensating capillary option exists for differential systems. Keep capillaries supported, shaded where possible and of equal length on both sides of a differential system.

Check seal material and connection standard against the process, including corrosion, abrasion and hygienic requirements, and confirm the transmitter approvals for the installation area.

Installation and commissioning of the EJXC81A

Install the EJXC81A with the seal flanges bolted to the process nozzles using gaskets suited to the process, and run the capillaries without sharp bends or mechanical stress. Never open or loosen the seal body, because the fill fluid system is closed at the factory, and zero the transmitter after installation with the actual process head in place.

Check the finished installation for leaks at the flange faces, record the zero reading with the process in a known condition, and keep the model code of the EJXC81A with the plant records so that a matching replacement can be ordered later.

Maintenance and calibration

Inspect the EJXC81A seal faces during turnarounds for build-up, corrosion or damage, and check that capillaries are undamaged and supported. A damaged diaphragm or lost fill fluid shows as drift or an unstable reading, and the seal assembly should then be replaced as a unit. Calibrate with the seals installed whenever the plant allows, so that the fill fluid effects are included.

Good practice for sealed systems also includes recording the installed capillary length, fill fluid and seal material on the asset register. These details decide the allowable temperature and pressure, and they are the first items a supplier needs when a replacement or a repair quotation is requested years after the initial commissioning.

Related products and ordering notes for the EJXC81A

Other Yokogawa models in the same product area include EJXC80A, EJXC50A, EJX310A and EJX310B, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a absolute pressure diaphragm seal system. The this model is the absolute pressure version of the Yokogawa diaphragm seal system. What measuring ranges does the this model cover? Datasheet values for the EJXC81A: One flanged seal is mounted on the high pressure side. Flush and extended flanged seals, as well as inner diaphragm seals in adapter and flange connection forms, are listed in the datasheet. The high temperature and high vacuum capability starts at 0.013 kPa abs.. What accuracy and output does the EJXC81A provide? For the EJXC81A the datasheet gives see the datasheet. Output and communication: see the datasheet.

Documents and quotation

The manufacturer datasheet for the EJXC81A is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJXC81A, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Yokogawa EJXC81A Absolute Pressure Diaphragm Seal System Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJXC81A Absolute Pressure Diaphragm Seal

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJXC81A?
The Yokogawa EJXC81A is a absolute pressure diaphragm seal system. The EJXC81A is the absolute pressure version of the Yokogawa diaphragm seal system.
02What measuring ranges does the EJXC81A cover?
Datasheet values for the EJXC81A: One flanged seal is mounted on the high pressure side. Flush and extended flanged seals, as well as inner diaphragm seals in adapter and flange connection forms, are listed in the datasheet. The high temperature and high vacuum capability starts at 0.013 kPa abs..
03What accuracy and output does the EJXC81A provide?
For the EJXC81A the datasheet gives see the datasheet. Output and communication: see the datasheet.
04What must be defined when ordering the EJXC81A?
The EJXC81A is defined by the model code: transmitter, seal type and size, fill fluid, capillary length and material. A complete code is needed to quote the correct system.
05How can I request a quotation for the EJXC81A in Oman?
Send an RFQ with the part number EJXC81A, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.