Brand:

Eaton FAZ-C16/3 Miniature Circuit Breaker 3-Pole C 16 A

Description

Eaton FAZ-C16/3 miniature circuit breaker, three-pole, C characteristic, 16 A

The Eaton FAZ-C16/3 (catalog number 278873) is a three-pole miniature circuit breaker from the xEffect FAZ range with a C tripping characteristic and a rated current of 16 A. It is a rail-mounted device, three modules wide, intended for the protection of cables and equipment against overload and short circuit in industrial and commercial distribution. The sheet lists a rated short-circuit breaking capacity of 10 kA at 400 V to IEC/EN 60898-1 and 15 kA to IEC 60947-2, together with current-limiting class 3. Seven Star LLC supplies the FAZ-C16/3 in Oman and the GCC for panel builders, electrical contractors and maintenance teams.

Reading the FAZ-C16/3 model code

FAZ is the miniature circuit breaker family. The letter C is the tripping characteristic: a C curve trips instantaneously between about 5 and 10 times the rated current, which suits loads with moderate inrush such as motors, transformers and lighting. The number 16 is the rated current in amperes, and the 3 after the slash is the number of poles. Variants of the same rating carry suffixes: -NA for versions listed to North American UL 489, -RT for current-limiting versions, and -NA-AS for a two-pole NA version.

FAZ-C16/3 technical specifications

Parameter Specification
Manufacturer / part number Eaton FAZ-C16/3 (catalog number 278873)
Series Eaton Moeller xEffect FAZ
Number of poles Three-pole (3 protected poles)
Tripping characteristic C
Rated current In 16 A
Rated operational voltage Ue, max 400 V
Voltage rating (IEC) 240 V AC / 415 V AC
Rated insulation voltage Ui 440 V
Voltage rating DC 60 V DC per pole
Rated frequency 50 / 60 Hz
Rated short-circuit breaking capacity Icn (IEC/EN 60898-1) at 400 V 10 kA
Rated short-circuit breaking capacity Icu (IEC 60947-2) at 230 V and 400 V 15 kA
Rated service short-circuit breaking capacity Ics 7.5 kA
Breaking capacity to UL 1077 10 kA
Current-limiting class / selectivity class 3 / 3
Rated impulse withstand voltage Uimp 4 kV
Overvoltage category / pollution degree III / 2
Back-up fuse, maximum 125 A gL/gG
Electrical lifespan 10,000 operations
Mounting Top-hat rail to IEC/EN 60715
Width 54 mm (3 modules); 17.5 mm per pole
Degree of protection IP20 (IEC); IP40 when fitted in an enclosure
Terminals Twin-purpose terminals top and bottom; connectable conductor 1–25 mm²
Busbar thickness 0.8 – 2 mm
Ambient operating temperature −25 to 75 °C
Weight 0.333 kg

The data follows the manufacturer specification sheet for catalog number 278873. The sheet lists approvals including IEC/EN 60898, IEC/EN 60947-2, UL 1077, CSA and CE marking, as well as EN 45545-2 and IEC 61373 for railway use.

What the C characteristic of the FAZ-C16/3 means

A miniature circuit breaker has two release elements. The thermal element follows the current over time and trips on moderate sustained overload. The magnetic element trips instantly on a short circuit, and its threshold depends on the characteristic. With the C curve of the FAZ-C16/3 the magnetic release operates in a range above the B curve and below the D curve, which allows brief inrush currents of lamps, small transformers and motors to pass without nuisance trips.

The sheet lists current-limiting class 3 and selectivity class 3, which describe how much let-through energy the breaker lets pass and how well it coordinates with upstream devices. A back-up fuse of up to 125 A gL/gG is permitted, which is useful where the short-circuit level at the board exceeds the breaking capacity of the breaker alone.

Where the FAZ-C16/3 is used

The FAZ-C16/3 protects three-phase feeders of up to 16 A: small motors, heater banks, distribution sub-circuits, pumps and the supply to control transformers and power supplies. In a motor circuit it provides short-circuit protection only; for overload protection of a motor, a motor-protective breaker such as the PKZM0 or PKE is the correct device, while the FAZ is typically used for cable and feeder protection. The sheet notes that the device can take additional equipment, such as auxiliary contacts and shunt releases.

Selection checklist for the FAZ-C16/3

  • Confirm the load current and the cable rating: 16 A is the maximum continuous current at reference temperature.
  • Select the characteristic: C for mixed loads, B for resistive and long cable runs, D for high inrush.
  • Compare the prospective short-circuit current at the board with 10 kA at 400 V, or use the permitted 125 A back-up fuse.
  • Note the DC rating of 60 V per pole when the breaker is considered for low-voltage DC circuits.
  • Check the ambient temperature: the sheet notes about 0.5 percent reduction of current-carrying capacity per degree of temperature increase.

Installation and maintenance of the FAZ-C16/3

Snap the FAZ-C16/3 onto a 35 mm rail and connect conductors of up to 25 mm² to the twin-purpose terminals, following the torque in the instruction leaflet. If a busbar is used, its thickness must lie between 0.8 and 2 mm. Test the breaker by operating the toggle and, in service, check terminals for heat marks during board inspections. After a short-circuit trip, find and clear the fault before resetting.

Typical applications in Oman and the GCC

MCBs are used in every distribution board in Oman and the Gulf, from industrial plants to commercial buildings. The temperature derating hint matters in hot switchrooms and outdoor boards where inside temperatures are high. The ambient range up to 75 °C listed on the sheet is useful, but current-carrying capacity falls as temperature rises, so size breakers with a margin.

Eaton FAZ 16 A models at a glance

Model Type Note
FAZ-C16/3 Three-pole, C, 16 A Version for IEC installations, 10 kA Icn at 400 V
FAZ-C16/3-NA Three-pole, C, 16 A Version for North America, UL 489 listed, 14 kA
FAZ-C16/3-RT Three-pole, C, 16 A Current-limiting FAZ-RT version
FAZ-C16/2-NA-AS Two-pole, C, 16 A NA-AS version

The table lists related 16 A FAZ devices; confirm ratings and approvals of each from its own sheet.

Information to send with an RFQ for FAZ-C16/3

  • Exact model FAZ-C16/3 (catalog number 278873) and the quantity, including spares.
  • Number of poles, rated current and tripping characteristic.
  • Prospective short-circuit current at the board.
  • Accessories needed, such as auxiliary contacts or shunt release.
  • Delivery location (Muscat, Sohar, Salalah or elsewhere in the GCC) and the date you need the goods.
  • Any documents you need with the quotation, such as an installation leaflet or declaration of conformity.

Documents and quotation

The manufacturer specification sheet for FAZ-C16/3 is attached on this page, so you can check the ratings, dimensions and approvals against your project before you order. Installation leaflets and declarations of conformity can be requested separately.

Seven Star LLC supplies Eaton industrial control products in Oman and the GCC. To request a quotation, send model FAZ-C16/3, the quantity and your delivery location, and we will confirm availability and lead time for your order.

Other Models in the Eaton Faz Range

Seven Star LLC supplies models from the Eaton Faz range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Eaton FAZ-C16/3 Miniature Circuit Breaker 3-Pole C 16 ACircuit BreakersYou are viewing this model
Eaton FAZ-C16/3-NA Miniature Circuit Breaker 3-Pole 16 A UL 489Circuit BreakersView details
Datasheets & Documents
  • PDF Datasheet Eaton FAZ-C16/3 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Eaton is a power management company that began in 1911, when Joseph O. Eaton started a truck axle business in New York and moved it to Cleveland, Ohio, in 1914. It grew from vehicle components into electrical equipment, hydraulics and aerospace systems. Since buying Cooper Industries in 2012, Eaton has been incorporated in Ireland with its head office in Dublin, and it is listed on the New York Stock Exchange.

Seven Star LLC lists Eaton NZM molded case circuit breakers, PKZM0 motor-protective circuit breakers and Bussmann series Class J fuses, and supplies them to panel builders and maintenance teams in Oman and the GCC.

Eaton company profile

Founded 1911, New York, USA, by Joseph O. Eaton
Early move Cleveland, Ohio, 1914
Headquarters Dublin, Ireland, since the 2012 Cooper Industries acquisition
Listing New York Stock Exchange (ETN)
Brands Eaton, Moeller, Bussmann, Crouse-Hinds, MTL and MEDC
Product families FAZ and PL miniature circuit breakers, NZM moulded-case breakers, DILM contactors, PowerXL variable frequency drives, 9PX and 93PM UPS, Bussmann fuses, hazardous-area enclosures and signalling

Milestones

  • 1911: Joseph O. Eaton starts an axle business in New York.
  • 1914: The business moves to Cleveland.
  • 2012: Eaton acquires Cooper Industries and redomiciles in Ireland.

Eaton circuit protection listed here

The NZMN1-A80 is a frame size 1 molded case circuit breaker rated 80 A with a thermomagnetic release for cable and system protection. The PKZM0-1,6 is a motor-protective circuit breaker whose overload release is adjustable from 1 to 1.6 A, used as a manual motor starter. The LPJ-35SP is a Bussmann series Low-Peak Class J time-delay fuse rated 35 A at 600 V AC. Older NZM and PKZ devices carry the Moeller name on the nameplate, and the type designations are the same.

Where Eaton breakers and fuses are used

Motor control centers, feeder panels, machine control cabinets and UL-style fused disconnects.

Eaton products we list

Family Examples
Circuit Breakers LPJ-35SP Class J Time-Delay Fuse, NZMN1-A80 Molded Case Circuit Breaker, NZMN2-A250 Molded Case Circuit Breaker, NZMN3-AE400 Molded Case Circuit Breaker, PKZM0-1
AC Drives DA1-342D2FB-A20C AC Drive, PowerXL DG1-34140FN-C21C Variable Freque…

Ordering Eaton parts: what we need

Send the full type and article number, the number of poles, the current rating or setting range, and any accessories such as auxiliary contacts, trip releases or rotary handles.

Facts checked against Eaton's corporate history and investor materials, October 2026.

FAQ

Questions about the Eaton FAZ-C16/3 Miniature Circuit Breaker 3-Pole C

Answers from our engineering team on installation, compatibility and integration.

01What type of breaker is the FAZ-C16/3?
A three-pole miniature circuit breaker with C tripping characteristic and a rated current of 16 A, mounted on a 35 mm top-hat rail and three modules wide.
02What is the breaking capacity of the FAZ-C16/3?
The sheet lists 10 kA at 400 V to IEC/EN 60898-1 and 15 kA to IEC 60947-2 at 230 V and 400 V. Ics is 7.5 kA. To UL 1077 the breaking capacity is 10 kA.
03What voltage can the FAZ-C16/3 be used on?
The voltage rating is 240/415 V AC and the maximum rated operational voltage is 400 V. For DC the rating is 60 V DC per pole.
04What conductors fit the FAZ-C16/3 terminals?
Conductors of 1 to 25 square millimetres can be connected to the twin-purpose terminals, and busbars of 0.8 to 2 mm thickness are accepted.
05Does ambient temperature affect the FAZ-C16/3?
Yes. The sheet notes that each degree of temperature increase reduces the current-carrying capacity by about 0.5 percent, and gives an ambient operating range of -25 to 75 degrees C.