Hanna HI8424 Portable pH/mV Meter with Temperature Probe

Description

Hanna HI8424 portable pH/mV meter with temperature compensation

The Hanna HI8424 is a handheld pH and mV meter with automatic temperature compensation, built for plant technicians who need laboratory-style resolution of 0.01 pH away from the bench. It reads pH from -2.00 to 16.00, mV in two ranges and temperature from -20.0 to 120.0 °C. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

The HI8424 is supplied as a ready-to-use kit with an HI1230B pH electrode, an HI7662 stainless-steel temperature probe, buffer and cleaning sachets, a protective case and batteries, so a single part number covers everything needed for a first measurement.

HI8424 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments HI8424
pH range / resolution -2.00 to 16.00 pH; 0.01 pH
pH accuracy at 25 °C ±0.01 pH
pH calibration Automatic, one or two points, with three memorised buffers (4.01, 7.01, 10.01)
mV range / resolution ±699.9 mV at 0.1 mV; ±1999 mV at 1 mV
mV accuracy ±0.2 mV; ±1 mV
Temperature -20.0 to 120.0 °C at 0.1 °C; accuracy ±0.4 °C
Temperature compensation Automatic from -20 to 120 °C, or manual without a temperature probe
Power One 9 V Ni-MH rechargeable battery; about 150 hours of continuous use
Environment 0 to 50 °C; RH up to 100 %
Size / weight 164 × 76 × 45 mm; 180 g
Supplied with HI1230B pH electrode, HI7662 temperature probe, HI70004 pH 4.01 and HI70007 pH 7.01 sachets, HI700601 cleaning sachets, battery, protective case, instructions
Warranty Two years

How the HI8424 works

A glass pH electrode generates a millivolt signal that changes with the hydrogen-ion activity of the sample. The meter measures that signal against the reference, applies the slope and offset found during calibration, and corrects for the Nernst temperature effect using the stainless-steel temperature probe.

Calibration is automatic: the meter recognises the memorised buffers 4.01, 7.01 and 10.01, accepts one or two points, and in mV mode it can also be used for ORP or ion-selective electrode work thanks to the BNC input. The wide -2.00 to 16.00 pH window allows strongly acidic or caustic process liquors to be read.

Where HI8424 fits: sensors, accessories and related models

The meter is paired with the HI1230B PEI-body pH electrode on a 1 m cable with BNC connector, and the HI7662 stainless-steel temperature probe on a 1 m cable. Consumables are the HI70004, HI70007 and HI70010 buffers, HI700601 cleaning sachets and storage solution; for process liquors with different chemistry, other Hanna electrodes can be fitted through the BNC connector.

The next table places the HI8424 beside the benchtop HI6221 so you can choose between portable and laboratory use.

HI8424 family comparison

Model Format pH range Accuracy
HI8424 Portable, 9 V Ni-MH -2.00 to 16.00 pH ±0.01 pH
HI6221 Benchtop, DC adapter -2.000 to 20.000 pH ±0.002 pH at highest resolution

The HI8424 suits routine plant checks and field verification; the HI6221 benchtop meter suits laboratories that need up to 0.001 pH resolution, five-point calibration and a larger display.

Selection and ordering checklist for HI8424

  • Confirm the sample chemistry suits the supplied HI1230B electrode, or quote an alternative electrode
  • Decide whether extra buffers (4.01, 7.01, 10.01) and cleaning solution should be added
  • Check the need for ORP or ion-selective work, which would use the mV mode
  • Plan a spare 9 V Ni-MH battery and charger if used continuously
  • Specify whether the 1 m cable length is adequate

Installation, calibration and maintenance of HI8424

Rinse the electrode and calibrate at one or two points before each shift, starting with pH 7.01 and then 4.01 or 10.01 depending on the expected sample range. Condition new or dry electrodes in storage solution, and clean with HI700601 sachets if the response slows.

Keep the temperature probe in the same sample as the electrode so that compensation reflects the actual liquid temperature. Do not store the electrode dry, and recharge the Ni-MH battery after prolonged storage.

For documentation, record the buffer lot numbers and calibration time in your own log, and replace the electrode when the slope can no longer be calibrated within the acceptable range. A glass electrode that reads slowly in a cleaned and conditioned state has usually reached the end of its life.

The case is intended to protect the meter in the field, but keep it away from solvents and from direct sun when parked in a vehicle in summer.

When ordering for a site with several instruments, standardise on the same electrode model and buffer lots so that readings from different meters can be compared. Keep the protective case closed between uses, label each meter with its calibration date, and schedule electrode replacement before the slope degrades, because a failing electrode wastes more time than a spare costs. For critical compliance samples, repeat the reading with a freshly calibrated meter and note both values in the log.

Typical applications of HI8424 in Oman and the GCC

Typical Oman uses include process-water and effluent pH checks at refineries and petrochemical plants, boiler and cooling-water treatment control, desalination chemical-dosing verification, and laboratory spot checks. The wide pH window helps with acid cleaning and caustic neutralisation streams.

Because the meter is portable and battery powered, one unit can be shared between several treatment skids and checked against the benchtop reading during routine audits.

Information to send with an RFQ for HI8424

  • Quantity and need for spare electrodes or temperature probes
  • Buffer and cleaning solution quantities
  • Sample type and temperature range
  • Delivery location and lead time
  • Project or tender reference

Documents and quotation

The instruction manual for the HI8424 is attached on this page for specifications, calibration procedures and maintenance steps.

Send the part number HI8424, the quantity and your delivery location and we will reply with availability and a quotation.

Other Models in the Hanna Ph Meter Range

Seven Star LLC supplies models from the Hanna Ph Meter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hanna HI8424 Portable pH/mV Meter with Temperature ProbeLiquid Analytical SystemsYou are viewing this model
Hanna HI6221 Advanced Benchtop pH/ORP Meter, 5-Point CalLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Manual Hanna HI8424 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna HI8424 Portable pH/mV Meter with Temperature

Answers from our engineering team on installation, compatibility and integration.

01What is the pH range and accuracy of the HI8424?
-2.00 to 16.00 pH at 0.01 pH resolution, with accuracy of 0.01 pH at 25 degrees C.
02What is supplied with the meter?
An HI1230B pH electrode, HI7662 temperature probe, buffer sachets (4.01 and 7.01), cleaning sachets, a battery, a protective case and instructions.
03How is it calibrated?
Automatically at one or two points, using three memorised buffers: pH 4.01, 7.01 and 10.01.
04Can it read mV?
Yes. It has a plus or minus 699.9 mV range at 0.1 mV resolution and a plus or minus 1999 mV range at 1 mV resolution.
05What temperatures does it compensate?
Automatic temperature compensation covers -20 to 120 degrees C using the temperature probe, or manual entry when no probe is connected.