Brand:

Fluke 719Pro-150G Electric Pressure Calibrator

Description

719Pro-150G electric pressure calibrator with built-in pump to 150 psi

The Fluke 719Pro-150G is a handheld electric pressure calibrator with an integrated pump that generates pressure up to 150 psig (10 bar) at the press of a button. It measures pressure from -12 psi to 150 psi at 0.025 % of full scale for six months, includes a full loop calibrator that sources, simulates and measures mA, and shows three parameters at once on a backlit screen. Seven Star LLC supplies the 719Pro-150G in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.

The ordering list shows Fluke-719Pro-30G, 719Pro-150G and 719Pro-300G, each described as an “Electric Pressure Calibrator” with the range in psig. The decoded name is below.

Element Meaning Detail
719Pro Model Electric pressure calibrator with built-in pump
150 Range in psi Gauge pressure up to 150 psi (10 bar)
G Gauge reference Relative to atmospheric pressure

719Pro-150G technical specifications

Parameter Specification
Manufacturer / part number Fluke / 719Pro-150G
Pressure range -12 to 150 psi (-0.8 to 10 bar)
Resolution 0.01 psi, 0.001 bar
Accuracy ±0.025 % of full scale for 6 months; ±0.035 % for 1 year
Media Dry air and non-corrosive gas only
Temperature effect Add ±0.002 % FS/°C outside 15 °C to 35 °C
mA dc 0 to 24 mA, 0.001 mA, ±0.015 % of reading + 2 counts; maximum 1000 Ω in source mode
Volts dc (measure) 30 V dc, 0.001 V, ±0.015 % of reading + 2 counts
Loop supply 24 V dc, 24 mA
Temperature (optional RTD probe) -50 °C to 150 °C, Pt100, combined uncertainty ±0.1 °C with the 720 RTD probe
Pump Integrated electric pump with programmable pressure limit and precision vernier
Pump life 300 pump cycles to 150 psi minimum, per battery set
Power Eight AA alkaline batteries
Size / weight 24.13 x 11.18 x 7 cm / 1.2 kg with holster
Connections 1/8 inch female NPT pressure; banana jacks; RTD and external module connectors
Operating temperature -10 °C to +50 °C

How the electric pump of the 719Pro-150G works for the technician

A pressure calibration needs a source, a reference and a way to fine adjust. In the 719Pro-150G the pump is inside the case, so one hand holds the unit and the other hand connects the device under test. The programmable pressure limit stops the pump at a target value, which prevents over-pressurising a device with a low range. A precision vernier trims the pressure to the exact test point for switches and gauges. Cleanout ports and the supplied fluid trap protect the pump from moisture, because the unit is for dry air and non-corrosive gas only.

The switch test function makes pressure switch testing easier than watching a continuity tester while slowly raising pressure, and the large backlit screen shows pressure, the mA value and, with the optional RTD probe, temperature together.

Range options and related models

The 719Pro-150G sits in the middle of three ranges. The 30G offers 0.001 psi resolution for low-pressure work, while the 300G reaches 20 bar and a shorter battery life of 100 pump cycles. The 718 range is a related pneumatic calibrator, and the 717 range has no internal pump. An external 29-module range extends measurement with 700Pxx pressure modules.

Model Range Resolution Pump cycles
719Pro-30G -12 to 30 psi 0.001 psi 1000 cycles to 30 psi
719Pro-150G -12 to 150 psi 0.01 psi 300 cycles to 150 psi
719Pro-300G -12 to 300 psi 0.01 psi 100 cycles to 300 psi

The 719Pro also extends its range with any of 29 700Pxx pressure modules connected to the 6-pin external module port, which allows the same unit to cover vacuum, low differential pressures or higher pressures with an external pump. When a module is used, the media compatibility and accuracy follow the module specification instead of the internal sensor, so check the module datasheet before connecting liquids.

Selecting the 719Pro-150G

  • Confirm that test devices operate with dry air or non-corrosive gas.
  • Verify the maximum pressure of 150 psi covers your devices, with margin for overshoot.
  • Consider an external 700Pxx module for liquids or ranges above 150 psi.
  • Decide whether the optional 720RTD probe and 720URTDA adapter are required for temperature.
  • Plan accessory hoses and adapters for the connections used on site.

Use and maintenance of the 719Pro-150G

Use fresh AA batteries; the pump consumes power at each stroke. Keep the fluid trap clean and empty it after use on at-risk applications. Zero the pressure channel before each series and use the supplied adapter for 1/4 inch ISO threads when needed. Store with the batteries per the manufacturer’s recommendation. A traceable certificate of calibration is included with every unit, and the carrying case is supplied.

Typical applications of the 719Pro-150G in Oman and the GCC

The 719Pro-150G suits field calibration of pressure transmitters and gauges on air systems, instrument air headers, fuel gas and utility lines in oil and gas, power and desalination plants. Technicians use the switch test on compressor and boiler pressure switches. Temperatures around 50 °C are common in summer plant areas, so keep the unit shaded.

Information to send with an RFQ for the 719Pro-150G

  • Part number 719Pro-150G (or the 30G or 300G range)
  • Quantity and accessories such as RTD probe or modules
  • Pressure ranges and media
  • Delivery location and time frame
  • Calibration certificate requirement

Storage, handling and spares for the Fluke 719Pro-150G

Keep the Fluke 719Pro-150G in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.

  • Check the instrument, cables, hoses or lenses for damage before each job.
  • Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
  • Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
  • Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.

For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 719Pro-150G, so the right documents can be confirmed with the quotation.

Documents and quotation

A datasheet covering the 719Pro range is attached on this page.

Send us the part number 719Pro-150G and the quantity and we will confirm availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.

Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.

Fluke company profile

Founded June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company
Founder John M. Fluke Sr.
Headquarters Everett, Washington, USA (moved to the Seattle area in 1952)
Ownership Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016
Product families Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards

Milestones

  • 1948: John Fluke starts the company in Springdale, Connecticut.
  • 1952: The company moves to Seattle
  • 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
  • 1998: Danaher acquires Fluke.
  • 2016: Fluke becomes part of Fortive, spun off from Danaher in July.

Fluke calibrators and test tools listed

The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:

  • Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
  • Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
  • Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source

Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.

Where Fluke instruments are used

Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.

Fluke products we list

Family Examples
Portable Test & Measurement 117 Electrician’s True-rms Multimeter with, 1507 Insulation Resistance Tester, 1550C 5 kV Insulation Resistance Tester, 1587 FC Insulation Multimeter, 376 FC True-RMS AC/DC Clamp Meter with iFlex, 5080A Multi-Product Calibrator, 5500A Multi-Product Calibrator, 5502A Multi-Product Calibrator and 17 more
Lubrication & Bearing Maintenance 805 FC Vibration Meter

Ordering Fluke instruments: what we need

Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.

Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.

Facts checked against published histories of Fluke Corporation and Fortive, October 2026.

FAQ

Questions about the Fluke 719Pro-150G Electric Pressure Calibrator

Answers from our engineering team on installation, compatibility and integration.

01What pressure range does the Fluke 719Pro-150G cover?
The 719Pro-150G covers -12 psi to 150 psi, or about -0.8 bar to 10 bar, with 0.01 psi resolution and an integrated electric pump.
02What is the accuracy of the Fluke 719Pro-150G?
The datasheet gives 0.025 % of full scale for six months and 0.035 % of full scale for one year, within 15 °C to 35 °C. Add 0.002 % FS per degree outside that band.
03Can the 719Pro-150G be used with liquids?
No. The datasheet states dry air and non-corrosive gas only. A fluid trap is supplied to protect the pump, and an external module is needed for liquids.
04Does the Fluke 719Pro-150G calibrate pressure switches?
Yes. It has a switch test function and a precision vernier for adjusting pressure. It also has a loop calibrator for sources and simulates mA signals.
05What power does the Fluke 719Pro-150G use?
It uses eight standard AA alkaline batteries, giving at least 300 pump cycles to 150 psi. The package includes a traceable certificate of calibration.