Brand: Beamex
Beamex MB Metrology Temperature Block
Description
Overview
Beamex MB is a user-friendly, highly accurate metrology temperature dry block that brings laboratory-level temperature calibration into the field and the workshop. The series covers temperatures from −45 °C to +700 °C across four models, MB140, MB155, MB425 and MB700, and delivers the accuracy normally associated with liquid baths in a convenient dry block. A conventional dry block usually needs an external reference sensor for better accuracy, whereas the Beamex MB has accurate internal temperature measurement with display accuracy up to ±0.1 °C.
Seven Star LLC supplies the Beamex MB on request to calibration laboratories, power plants, refineries and quality departments in Oman and the GCC, with engineering support in Muscat. Because the MB is a heat source rather than a measuring instrument, buyers normally pair it with a documenting calibrator such as the Beamex MC6 advanced field calibrator and communicator, which reads the reference probe and the sensor under test.
Temperature Control Principle
A dry block creates a stable temperature zone inside a metal insert, and a temperature sensor placed in the insert is compared with a reference. The Beamex MB improves on this with unique temperature control techniques that give stability of up to ±0.005 °C, a figure usually found only in baths. Dual-zone control and an extended well depth hold the lower and upper parts of the well at a uniform temperature, so the axial uniformity reaches up to ±0.02 °C over the working length.
Uniformity across the insert is just as important as stability. Radial uniformity, the temperature difference between the holes of the insert, is up to ±0.01 °C, so a reference sensor and a sensor under test see the same temperature. The immersion depth of up to 203 mm (160 mm in the MB140) reduces stem conduction error, the heat that flows up the probe stem into the air, which becomes more significant at high temperature. The dual-zone design also compensates for loading when several probes are inserted, with loading effects as low as ±0.005 °C.
Engineering Design of the Beamex MB
The Beamex MB measures 366 x 203 x 323 mm and weighs 12.2 to 14.6 kg depending on the model, which makes it transportable for field calibration trips. The MB140 covers −45 to 140 °C and the MB155 −30 to 155 °C, both with ±0.1 °C display accuracy over the full range. The MB425 covers 35 to 425 °C and the MB700 covers 50 to 700 °C, calibrated to 660 °C with a reference thermometer recommended at higher temperatures. The two low-temperature models run on 550 W and the high-temperature models on 1025 W, from 115 or 230 V mains.
A ten-key keypad, an LCD in °C or °F and a resolution of 0.001 degrees make the block easy to operate, and an RS-232 interface allows computer control. Multi-hole inserts MH1 and MH2 accept metric and imperial probe diameters such as 3, 4, 6, 8 and 10 mm and 1/4 inch, and blank and special inserts can be ordered. The R model adds a built-in reference thermometer input for a 100 ohm PRT through a 4-wire 6-pin Lemo connector, with resistance accuracy of 25 ppm of reading from 20 to 400 ohms and ITS-90, CVD and resistance characterisations. An accredited calibration certificate is supplied.
Key Features
The Beamex MB combines laboratory performance with portability:
- Four models cover −45 to +700 °C, from refrigeration and cold-chain checks to high-temperature process sensors.
- Display accuracy of up to ±0.1 °C and stability up to ±0.005 °C give bath-like performance without liquid.
- Dual-zone control and long well depth deliver axial uniformity up to ±0.02 °C for reliable comparison of reference and test probes.
- Radial uniformity up to ±0.01 °C ensures all insert holes are at the same temperature.
- Immersion depth up to 203 mm limits stem conduction error, which is important for long industrial probes at high temperature.
- Loading specifications up to ±0.005 °C keep temperature stable when several probes are inserted at once.
- The R model includes a built-in reference sensor input with reading accuracy of up to ±0.006 °C, avoiding a separate reference thermometer.
- RS-232 computer interface and an accredited calibration certificate support automated and traceable calibration work.
Industrial Applications
The Beamex MB is used to calibrate RTDs, thermocouples, temperature switches and thermometers in power generation, oil and gas, chemical, pharmaceutical, food and beverage and heat-treatment applications. The low-temperature models suit refrigeration, cold storage and cryogenic-adjacent checks, while the MB425 and MB700 cover steam, flue gas and furnace sensors. A calibration laboratory can use it as a working standard for field sensors, and a maintenance team can bring it to the instrument for a sensor check at the point of installation.
For customers in Oman, Seven Star LLC supports temperature calibration programmes in utility plants, desalination units, refineries in Sohar and Duqm, and food and beverage factories in Muscat. Teams comparing dry blocks often look at the Isotech Jupiter 4852 portable dry block calibrator or the Isotech Europa 4520 Isocal-6 dry block temperature calibrator, and we can help weigh range, uniformity and portability. Request the Beamex MB datasheet to review the full specification for each model.
Technical Specifications
Specifications of the Beamex MB series are summarised from the manufacturer brochure. Figures are valid at 18 to 28 °C ambient temperature.
| Parameter | Specification |
|---|---|
| Model | Beamex MB metrology temperature block (MB140, MB155, MB425, MB700) |
| Temperature range | MB140 −45 to 140 °C; MB155 −30 to 155 °C; MB425 35 to 425 °C; MB700 50 to 700 °C |
| Display accuracy | ±0.1 °C (MB140, MB155); up to ±0.2 °C (MB425); up to ±0.25 °C (MB700) |
| Stability | ±0.005 °C (MB140, MB155); ±0.005 to ±0.03 °C (MB425, MB700) |
| Immersion depth | 160 mm (MB140); 203 mm (other models) |
| Resolution | 0.001 °C / °F |
| Insert diameter | 30.0 mm (29.2 mm for MB700) |
| Reference input (R model) | 0 to 400 Ω, 4-wire; ITS-90, CVD, resistance |
| Power | 115 or 230 V AC; 550 W (MB140, MB155); 1025 W (MB425, MB700) |
| Dimensions | 366 x 203 x 323 mm |
| Weight | 12.2–14.6 kg |
| Interface and warranty | RS-232; accredited calibration certificate; 1 year warranty |
Request a Quote for Beamex MB
To request a quotation for the Beamex MB, tell Seven Star LLC the temperature range, probe diameters and reference thermometer option you need. We supply the Beamex MB on request with engineering support in Muscat and can send the Beamex MB datasheet and insert options to calibration and procurement teams across Oman and the GCC.
See also: Beamex EXT External Pressure Modules, 70 kPa to 100 MPa.
Datasheets & Documents
- Brochure Beamex MB Metrology Temperature Block Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex MB Metrology Temperature Block
Answers from our engineering team on installation, compatibility and integration.
01What temperature range does the Beamex MB cover?
The series covers −45 to 700 degrees C across four models: MB140 from −45 to 140 degrees C, MB155 from −30 to 155, MB425 from 35 to 425 and MB700 from 50 to 700, calibrated to 660 degrees C.
02How stable is the Beamex MB?
Stability reaches ±0.005 degrees C on the MB140 and MB155 and between ±0.005 and ±0.03 degrees C on the high-temperature models, depending on range. Dual-zone control and a deep well deliver axial uniformity up to ±0.02 degrees C.
03Do I need an external reference thermometer?
Not always. The display accuracy of up to ±0.1 degrees C is good without one, and the R model has a built-in reference sensor input with accuracy up to ±0.006 degrees C. A reference thermometer is recommended above 660 degrees C on the MB700.
04What probe sizes fit the inserts?
Multi-hole inserts MH1 and MH2 accept probes of 3, 4, 6, 8 and 10 mm and 1/4 inch in various combinations, and blank and special inserts can be ordered for non-standard sensors.
05Does Seven Star LLC supply the Beamex MB in Oman?
Seven Star LLC supplies genuine Beamex MB temperature blocks to Oman and the GCC, with engineering support in Muscat. We can quote the model, inserts and reference option you need and share the manufacturer documentation.