Schneider Electric LADS2 TeSys D On-Delay Timer Block 1-30 s

Description

LADS2: on-delay timer block listed for star-delta starters

The LADS2 is a Schneider Electric TeSys D time delay auxiliary contact block with an on-delay function and a range of 1 to 30 seconds, and its datasheet notes the application as star delta starter. It carries one normally open and one normally closed timed contact. Seven Star LLC supplies the LADS2 in Oman and the GCC as an independent supplier based in Muscat.

Among the five timers here, the LADS2 is the only one whose datasheet names a device application. It has the same on-delay range as the LADT2, so the star-delta mention is the practical difference between the two references.

Technical specifications of the LADS2

Parameter Specification
Manufacturer / part number Schneider Electric / LADS2
Description Product datasheet Time delay auxiliary contact block, TeSys D, 1NO + 1NC, on delay 1-30s, front, screw clamp terminals
Range TeSys; TeSys Deca
Product name TeSys Deca
Product or component type Time delay auxiliary contact block
Range compatibility TeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F
Device application Star delta starter
Mounting location Front
Pole contact composition 1 NO + 1 NC
Contacts operation Time delay
Timer type On delay
Time delay range 1 to 30 s
[Ue] rated operational voltage 690 V AC 25 to 400 Hz
[Ie] rated operational current 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1
[Ith] conventional free air thermal 10 A (at 60 °C)
Standards EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certifications IECEE CB Scheme; UL; CSA; CCC; EAC; UKCA
Irms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1; 250 A at <= 690 V DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms
Protection type GG fuse 10 A
Mechanical durability 5 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1 to 2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 2.5 mm²flexible without cable end
Height 48 mm
Width 44 mm
Depth 61 mm
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature (operation, as listed) -40 to 70 °C
Operating altitude 3000 m

The star-delta job of the LADS2

A star-delta starter starts a motor with its windings in star to limit starting current, then changes over to delta after a set time. The timer must hold the star contactor in for the run-up and then drop it. A range of 1 to 30 seconds covers the run-up of most pumps and fans of moderate size.

The on-delay function means the contacts change state after the set time following energisation of the contactor, which is what the changeover needs. Set the time to the actual run-up of the machine, and not to a guess, by measuring the current or speed during the first starts.

LADS2 selection notes

  • On delay, 1 to 30 s; contacts 1 NO + 1 NC.
  • Application noted: star delta starter.
  • Compare with the LADT2, which has the same range without the star-delta note.
  • Compare with the LADT4 if the run-up exceeds 30 s.
  • Contactor compatibility as in the datasheet.

Ratings and mounting of the LADS2

The block fits on the front of TeSys D and TeSys Deca contactors and CAD relays, and on TeSys F LC1F and CR1F, which is the range compatibility line in the datasheet. It has one normally open and one normally closed time-delayed contact and measures 48 mm high, 44 mm wide and 61 mm deep. Rated operational voltage is 690 V AC at 25 to 400 Hz, thermal current is 10 A at 60 °C, rated current is 6 A at 120 V AC-15 and 1.04 A at 690 V AC-15, and the making capacity is 140 A AC. Mechanical durability is 5 Mcycles, the minimum switching level is 5 mA at 17 V, and the protection is IP20. The ambient air temperature range is -40 to 70 °C and the altitude limit is 3000 m.

The datasheet adds a short-time rating of 100 A for 1 s, 120 A for 500 ms and 140 A for 100 ms at 60 °C.

Timer block family: the LADS2 against its siblings

The five timer blocks below share the housing and contact ratings and differ in function and range.

Reference Timer type Delay range Application noted
LADR0 Off delay 0.3 to 3 s Not stated
LADR2 Off delay 1 to 30 s Not stated
LADS2 On delay 1 to 30 s Star delta starter
LADT2 On delay 1 to 30 s Not stated
LADT4 On delay 10 to 180 s Not stated

Setting up a star-delta timer with the LADS2

Fit the block on the star contactor, wire the changeover chain according to your starter diagram, and set the delay to the run-up time. Terminals take 1 to 2.5 mm² flexible, tightened at 1.7 N.m.

Observe the first start with a clamp meter. The current peak at changeover tells whether the time is too short, and a long star period tells it is too long.

LADS2 in Oman and the GCC

Star-delta starting is widely used for pumps, compressors and fans of tens of kilowatts in water, HVAC and industrial plants, where a direct-on-line start would stress the supply. The LADS2 is the timer that those panels use.

Supply networks in remote sites can be weak, so correct changeover timing is more than a nicety.

Information to send with an RFQ for the LADS2

  • Full reference and quantity required
  • Contactor model the block mounts on
  • Delay function (on or off) and time range needed
  • Control voltage and load of the timed contacts
  • Delivery location and timing

Documents and quotation

A datasheet for the LADS2 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys D Timer Range

Seven Star LLC supplies models from the Se Tesys D Timer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LADR0 TeSys D Off-Delay Timer Block 0.3-3 sContactors & Overload RelaysView details
Schneider Electric LADS2 TeSys D On-Delay Timer Block 1-30 sContactors & Overload RelaysYou are viewing this model
Schneider Electric LADT2 TeSys Deca On-Delay Timer Block 1-30 sContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric LADS2 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LADS2 TeSys D On-Delay Timer

Answers from our engineering team on installation, compatibility and integration.

01What is the delay range of the LADS2?
1 to 30 seconds. See the datasheet linked on this page for the full figures.
02Is the LADS2 on delay or off delay?
On delay. See the datasheet linked on this page for the full figures.
03What application does the datasheet note for the LADS2?
Star delta starter. See the datasheet linked on this page for the full figures.
04What contacts does the LADS2 have?
1 NO + 1 NC time delayed. Check that this arrangement matches your control circuit before ordering.
05What contactors fit the LADS2?
TeSys D and Deca, TeSys F LC1F and CR1F, as listed in the datasheet.