Schneider Electric LRD22L TeSys Deca 17-24 A Class 20 Relay
Description
LRD22L: 17 to 24 A class 20 overload relay in plain terms
The LRD22L is a Schneider Electric product listed in the datasheet as: Thermal overload relay, TeSys Deca, 690VAC, 17 to 24A, 1NO+1NC, class 20, for D25 to D38, screw clamp. In a motor starter it is the part that watches the current of the motor and opens the control circuit when an overload or a lost phase would otherwise overheat the windings. Seven Star LLC supplies the LRD22L in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: the datasheet identifies the LRD22L as part of the TeSys LRD family, and the title gives the figure that matters, namely the adjustable window of 17 to 24 A with thermal class 20. It is built as the compact frame (45 mm wide) used with LC1D09 to LC1D38 contactors. This is the one class 20 relay in this group. The longer trip class lets motors with heavy or slow-starting loads, such as large fans with high inertia, crushers, centrifuges and long conveyors, accelerate without tripping on the start current, while still protecting the windings.
Technical specifications of the LRD22L
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LRD22L |
| Description | Thermal overload relay, TeSys Deca, 690VAC, 17 to 24A, 1NO+1NC, class 20, for D25 to D38, screw clamp |
| Range | TeSys; TeSys Deca |
| Product name | TeSys LRD; TeSys Deca |
| Product or component type | Differential thermal overload relay |
| Relay application | Motor protection |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Thermal protection adjustment range | 17 to 24 A |
| Tripping threshold | 1.14 ± 0.06 Ir conforming to IEC 60947-4-1 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Network type / frequency | AC; DC / 0 to 400 Hz |
| Rated operational voltage [Ue] | 690 V AC 0 to 400 Hz for power circuit conforming to IEC 60947-4-1 |
| Rated insulation voltage [Ui] | Power circuit: 600 V conforming to CSA; Power circuit: 600 V conforming to UL; Power circuit: 690 V conforming to IEC 60947-4-1 |
| Rated impulse withstand [Uimp] | 6 kV |
| Auxiliary contact composition | 1 NO + 1 NC |
| Signalling circuit permissible current | 3 A at 120 V AC-15 for signalling circuit; 0.22 A at 125 V DC-13 for signalling circuit |
| Associated fuse (signalling circuit) | 4 A gG for signalling circuit; 4 A BS for signalling circuit |
| Product compatibility | LC1D25, LC1D32, LC1D38 |
| Mounting support | Plate, with specific accessories; Rail, with specific accessories; Under contactor |
| Temperature compensation | -20 to 60 °C |
| Power circuit connection | screw clamp terminals 1 cable 1.5 to 10 mm² flexible without cable end; screw clamp terminals 1 cable 1 to 6 mm² flexible with cable end; screw clamp terminals 1 cable 1.5 to 10 mm² solid without cable end |
| Tightening torque | Control circuit: 1.7 N.m – on screw clamp terminals; Power circuit: 2.5 N.m – on screw clamp terminals |
| Dimensions (W x H x D) | 45 mm x 66 mm x 76 mm |
| Net weight | 0.144 kg |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature (operation) | -20 to 60 °C without derating conforming to IEC 60947-4-1 |
| Ambient air temperature (storage) | -60 to 70 °C |
| Product certifications | IEC; UL; CSA; EAC; ABS; ATEX INERIS; UKCA |
How the LRD22L reacts to overload
The setting dial of the LRD22L covers 17 to 24 A. The datasheet gives the tripping threshold as 1.14 ± 0.06 Ir conforming to IEC 60947-4-1, which means the relay is built to trip when the motor current reaches about 1.14 times the dialled value, with a tolerance of 0.06 times. At the top of the scale, 1.14 times 24 A works out to about 27.36 A; at the bottom of the scale, 1.14 times 17 A is about 19.38 A.
The relay is also a differential type. For the phase failure case, the datasheet states a tripping current of 130 % of Ir on two phases while the third carries nothing, which at 24 A corresponds to about 31.2 A in the two live phases. This sensitivity is what protects a three-phase motor from running on two phases after a blown fuse or a loose terminal, and it is the reason the type is chosen over a simple thermal element for pumps and fans.
Class 20 allows a longer tripping time than class 10A. Under IEC 60947-4-1 the class number is the longest tripping time in seconds at 7.2 times the setting current, so a class 20 relay can ride through a slow, heavy start that a class 10A relay might cut short. The relay has temperature compensation over -20 to 60 °C, so the setting does not drift within that band.
Contactors and mounting for the LRD22L
The datasheet lists the contactors compatible with the LRD22L as LC1D25, LC1D32, LC1D38. The mounting options are plate, with specific accessories; rail, with specific accessories; under contactor. In practice the relay plugs straight under a TeSys Deca contactor of the listed frames, so the contactor and relay together form a compact direct-on-line or reversing starter without extra wiring in the power circuit.
The relay body measures 45 mm wide, 66 mm high and 76 mm deep and weighs 0.144 kg. It belongs to the compact frame (45 mm wide) used with LC1D09 to LC1D38 contactors. Class 20 gives more time on an overload than class 10A, so use it deliberately: the motor and cable must be able to tolerate the longer overload window. Do not swap class 10A for class 20 just to avoid nuisance trips without finding the cause.
Wiring the LRD22L: terminals and aux contact
On the power side the datasheet lists screw clamp terminals 1 cable 1.5 to 10 mm² flexible without cable end; screw clamp terminals 1 cable 1 to 6 mm² flexible with cable end; screw clamp terminals 1 cable 1.5 to 10 mm² solid without cable end. The tightening torque is listed as control circuit: 1.7 N.m – on screw clamp terminals; power circuit: 2.5 N.m – on screw clamp terminals. Use a torque screwdriver, because terminals on motor starters loosen over time with heat cycling and vibration.
The control side is a pair of contacts, described as 1 NO + 1 NC, with terminal marking 95 and 96 for the normally closed contact and 97 and 98 for the normally open contact. The permissible current of that signalling circuit is 3 A at 120 V AC-15 for signalling circuit; 0.22 A at 125 V DC-13 for signalling circuit, and the associated protection is 4 A gG for signalling circuit; 4 A BS for signalling circuit. Wire the normally closed contact in series with the contactor coil so that a trip drops the contactor, and use the normally open contact for a fault lamp or a PLC input.
Selection checklist for the LRD22L
- Motor nameplate current: it must sit between 17 and 24 A, ideally in the middle of the dial.
- Contactor: the starter must use one of LC1D25, LC1D32, LC1D38.
- Trip class: this relay is class 20; confirm that it suits the starting time of the load.
- Signalling circuit: the contact is rated 3 A at 120 V AC-15 for signalling circuit; 0.22 A at 125 V DC-13 for signalling circuit.
- Space: allow 45 mm x 66 mm x 76 mm and a weight of 0.144 kg.
- Status: say whether you need a spare for an existing starter or a new installation.
Where the LRD22L is used in Oman and the GCC
The compact frame is the workhorse of small motor control centres, local starter panels and skid-mounted packages, where many identical starters sit side by side and panel space is tight. In Oman and the GCC such starters appear in water and desalination plants, oil and gas auxiliaries, power station balance-of-plant and building services.
Heat and dust are the main enemies. Overload relays are temperature-compensated, but a hot, dusty panel still ages terminals and contacts faster, so inspect the connections of the LRD22L during planned shutdowns and keep the front cover and dial clean.
Environment, approvals and standards for the LRD22L
The datasheet gives an operating ambient temperature of -20 to 60 °C without derating conforming to IEC 60947-4-1 and a storage range of -60 to 70 °C, with IP20 protection and V1 flame retardance. It states mechanical robustness as Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7; Vibrations: 3 GN conforming to IEC 60068-2-6. On sites in Oman the actual panel temperature in summer can be well above the outdoor mean when panels are in the sun, so compare your measured cabinet temperature with the datasheet limit and add ventilation or shading where needed.
Certifications listed for the LRD22L are IEC; UL; CSA; EAC; ABS; ATEX INERIS; UKCA. The standards named are EN/IEC 60947-4-1; EN/IEC 60947-5-1; UL 60947-4-1; UL 60947-5-1; CSA C22.2 No 60947-4-1; CSA C22.2 No 60947-5-1; EN 50495. Only rely on a certificate that is listed here for this exact reference; if a project needs a particular marine or hazardous-area approval, tell us and we will check it against the datasheet before quoting.
Information to send with an RFQ for the LRD22L
- Full reference LRD22L and the quantity required
- Motor nameplate current, voltage and power
- Contactor reference the relay will be fitted to
- Required delivery location and timing
- Whether it is a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is the document to check against your own drawings.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Lrd F1 Range
Seven Star LLC supplies models from the Se Lrd F1 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LRD01 TeSys 0.1-0.16 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRD12 TeSys 5.5-8 A Overload Relay | Contactors & Overload Relays | View details |
| Schneider Electric LRD22L TeSys Deca 17-24 A Class 20 Relay | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LRD22L Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LRD22L TeSys Deca 17-24 A Class
Answers from our engineering team on installation, compatibility and integration.
01What current range does the LRD22L cover?
The datasheet gives a thermal protection adjustment range of 17 to 24 A with class 20 tripping, so the motor nameplate current should fall inside that window.
02Which contactors can the LRD22L be mounted on?
The datasheet lists LC1D25, LC1D32, LC1D38. The relay mounts under the contactor and can also be used on a plate or rail with specific accessories.
03How does the LRD22L react to a lost phase?
It is a differential relay. The datasheet states a tripping current of 130 % of Ir on two phases with the third at zero, in addition to the 1.14 +/- 0.06 Ir overload threshold.
04What auxiliary contacts does the LRD22L have?
The datasheet lists 1 NO + 1 NC, with a signalling-circuit rating of 3 A at 120 V AC-15 for signalling circuit; 0.22 A at 125 V DC-13 for signalling circuit. The normally closed contact is normally wired into the contactor coil circuit.
05What are the size and weight of the LRD22L?
The datasheet gives 45 mm wide, 66 mm high, 76 mm deep and a net weight of 0.144 kg.