Brand: Schneider Electric
Schneider Electric LUCM18BL TeSys Ultra Multifunction Control
Description
LUCM18BL multifunction control unit for TeSys Ultra starters
The LUCM18BL is a Schneider Electric product listed in the datasheet as: Multifunction control unit, TeSys Ultra, 4.5A to 18A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24VDC. The LUCM18BL is the multifunction control unit of the TeSys Ultra starter. It plugs into a power base and provides motor protection with adjustable class, diagnostics and a serial interface, instead of the fixed behaviour of the standard units. Seven Star LLC supplies the LUCM18BL in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: LUC marks a TeSys Ultra control unit, M the multifunction type, 18 the 18 A top of the current range and BL the 24 V DC coil. The datasheet gives the adjustable current range as 4.5 to 18 A.
Technical specifications of the LUCM18BL
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LUCM18BL |
| Description | Multifunction control unit, TeSys Ultra, 4.5A to 18A, 1P/3P motors, protection & diagnostic, class 5-30, coil 24VDC |
| Range | TeSys |
| Range of Product | TeSys Ultra |
| Product name | TeSys Ultra |
| Device short name | LUCM |
| Product or Component Type | Multifunction control unit |
| Device Application | Motor control; Motor protection |
| Product Specific Application | Most sophisticated control and protection requirements, with display |
| main function available | Manual or automatic reset; Protection function alarm; Protection against phase failure and phase imbalance |
| Product compatibility | Power base LUB32; Power base LUB38; Power base LUB320; Power base LUB380; Reversing contactor breaker LU2B32FU |
| [Ue] rated operational voltage | 690 V AC |
| Network frequency | 40 to 60 Hz |
| Load type | 3-phase motor self-cooled factory setting; 3-phase motor self-cooled, force cooled settable |
| Utilisation category | AC-41; AC-43; AC-44 |
| Motor power kW | 7.5 kW 400 to 440 V AC 50/60 Hz 3 phase; 9 kW 500 V AC 50/60 Hz 3 phase; 15 kW 690 V AC 50/60 Hz 3 phase; 4 kW 400 to 440 V AC 50/60 Hz 1 phase |
| rated motor current adjustment | 4.5 to 18 A |
| Thermal overload class | Class 5 to 30 50 to 60 Hz -25 to 55 °C IEC 60947-6-2; Class 5 to 30 50 to 60 Hz -25 to 55 °C UL 508 |
| Tripping threshold | 14.2 x Ir ± 20 % |
| [Uc] control circuit voltage | 24 V DC |
| Control circuit voltage limits | 20 to 28 V DC 24 V in operation; 14.5 V DC 24 V drop-out |
| Typical current consumption | 220 mA 24 V DC I maximum while closing with LUB32; 220 mA 24 V DC I maximum while closing with LUB38; 80 mA 24 V DC I rms sealed with LUB32 |
| Heat dissipation | 1.8 W control circuit with LUB32; 1.8 W control circuit with LUB38; 0.8 W external auxiliary circuit |
| Operating time | 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 65 ms closing with LUB32 control circuit |
| Physical interface | RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s |
| Return time | <= 200 ms |
| Messages display capacity | 2 lines of 12 characters LCD – English ± 5 % 1 % of Ir; 2 lines of 12 characters LCD – French ± 5 % 1 % of Ir |
| Reset | Automatic reset setting range; Manual factory setting; Manual setting range; Remote reset setting range |
| Time before reset | 1 to 1000 s manual or automatic reset settable; 120 s manual factory setting |
| User language | English factory setting; English, French, German, Italian, Spanish settable |
| Information displayed | Average current factory setting; Average current settable; Cause of last 5 faults settable; Current in phase settable |
| Standards | EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier |
| Product Certifications | CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine |
| [Ui] rated insulation voltage | 690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand | 6 kV IEC 60947-6-2 |
| Safe separation of circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 |
| Fixing mode | Plug-in (front face) |
| Width | 45 mm |
| Height | 66 mm |
| Depth | 60 mm |
| Net Weight | 0.175 kg |
| Compatibility code | LUCM |
Protection range and information provided by the unit
Motor current adjustment range: 4.5 to 18 A. Thermal overload class: Class 5 to 30 50 to 60 Hz -25 to 55 °C IEC 60947-6-2; Class 5 to 30 50 to 60 Hz -25 to 55 °C UL 508. Short-circuit trip threshold: 14.2 x Ir ± 20 %. Main functions: Manual or automatic reset; Protection function alarm; Protection against phase failure and phase imbalance. Communication interface: RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s. Information displayed: Average current factory setting; Average current settable; Cause of last 5 faults settable; Current in phase settable.
A multifunction unit goes beyond a thermal trip. It records motor load, tripping history and the cause of a stop, and provides parameters through a front RS485 connection. This lets a maintenance engineer read the cause of a nuisance trip rather than guessing.
Compatible bases and the place of the LUCM18BL in a starter
The datasheet lists the power bases that accept the unit (LUB and related types); the base decides the frame, short-circuit rating and reversing. A base such as LUB12 would carry a lower current than this unit can adjust to, so the base current limits the useful range.
On the control side the unit takes 24 V DC and can be run from a PLC or from a communication module. For networking, add the appropriate communication module (Modbus and others, per the datasheet).
The datasheet downloaded for this page carries lifecycle notices: Discontinued on: Jul 2, 2025. For a plant that already runs this reference that makes the LUCM18BL a spare-and-replacement item, and it is worth fixing the stock level and the long-term successor plan at the same time. We can discuss compatible alternatives once we know the installation.
Selection checklist for the LUCM18BL
- Motor current falls inside 4.5 to 18 A and the base is of equal or higher rating.
- Overload class (5 to 30) suits the starting time of the load.
- 24 V DC supply and its current margin.
- Whether serial or fieldbus data are needed.
- Language of the display and the parameters that must be reachable.
- Lifecycle: the datasheet carries a discontinuation notice, so plan the replacement path.
Setting up and servicing the LUCM18BL
Plug the unit into the power base until it locks, set the motor current and class with the front keys, and set the reset mode (manual or automatic, with the time before reset). Test the trip function by simulating a fault with the current-injection method recommended in the manual.
If the unit is replaced, copy the parameters from the old unit or keep a record of them: motor current, class and communication address. A replacement can be fitted live-off only; de-energise the starter first.
Typical applications of the LUCM18BL in Oman and the GCC
This unit is used where a motor needs more monitoring than a bimetal relay: process pumps, compressors, extruders and fans in the region. The ability to set a class from 5 to 30 matters for loads with long accelerating times such as high-inertia fans.
Dimensions, environment and approvals of the LUCM18BL
For the LUCM18BL, plan the mounting space from the datasheet: 45 mm (W) x 66 mm (H) x 60 mm (D). The LUCM18BL weighs 0.175 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -25 to 60 °C. Ingress protection: IP20 front panel and wired terminals IEC 60947-1; IP20 other faces IEC 60947-1; IP40 front panel outside connection zone IEC 60947-1. Operating altitude: 2000 m. Vibration resistance: 2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6. Shock resistance: 10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27. Standards listed: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier. Certifications listed for this reference: CE; UL; CSA; CCC; EAC; ASEFA; ATEX; Marine.
Information to send with an RFQ for the LUCM18BL
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric LUCM18BL Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LUCM18BL TeSys Ultra
Answers from our engineering team on installation, compatibility and integration.
01What current range can the LUCM18BL cover?
The datasheet states 4.5 to 18 A.
02What overload classes can be set?
Listed: Class 5 to 30 50 to 60 Hz -25 to 55 °C IEC 60947-6-2; Class 5 to 30 50 to 60 Hz -25 to 55 °C UL 508.
03What control voltage does the LUCM18BL need?
Listed: 24 V DC.
04What communication interface is built in?
The datasheet lists RS485 multidrop RJ45 front panel Modbus RTU 19200 bit/s.
05Which standards does the LUCM18BL list?
Listed: EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier.