Delta AX-500SC00-0S AX-5 Safety CPU Module

Description

Delta AX-500SC00-0S AX-5 safety CPU module

The Delta AX-500SC00-0S is the functional safety controller of the AX-5 series. It is a narrow safety CPU module intended to work with an AX-5 standard controller, so that safety logic runs in a dedicated safety processor while the machine program stays in the standard CPU. Seven Star LLC supplies the AX-500SC00-0S in Oman and the GCC as an independent supplier in Muscat.

The part number is a single orderable model, not a range. Delta publishes it as the AX-5 Series Safety CPU, model AX-500SC00-0S. Do not substitute it with a standard CPU such as the AX-5 CPU models, because the two modules play different roles.

AX-500SC00-0S technical specifications

Parameter Specification
Manufacturer / part number Delta Electronics / AX-500SC00-0S
Programming software DIADesigner-AX
Terminal block Removable terminal block (16 terminals)
Max. safety I/O points 256
Program capacity 256 Byte
Max. FSoE slaves supported 64
Dimensions (W x H x D) 12 mm x 100 mm x 80 mm
Weight 70 g
Safety integrity level SIL 3 (IEC 61508, IEC 62061)
Performance level PL e, Category 4 (ISO 13849-1)

Safety parameters of the AX-500SC00-0S

The manufacturer publishes the following safety figures for the module. They are the numbers a safety engineer needs when calculating the overall safety function of a machine, and they should be copied from the manufacturer document into the project’s safety calculation rather than from this page.

Safety parameter Value
Diagnostic coverage ≥ 99%
Safe failure fraction ≥ 90%
Subsystem element type Type B
Hardware fault tolerance HFT = 1
Proof test interval ≥ 20 years
PFHD 2.51 E-10
PFDavg 2.14 E-5
MTTFd 99.8 years

How the AX-500SC00-0S works

The AX-500SC00-0S executes the safety program in its own processor and exchanges safe data with remote safety I/O over EtherCAT using Fail Safe over EtherCAT (FSoE). It can address up to 64 FSoE slaves and 256 safety I/O points. Because the program capacity is only 256 Byte, the module is meant for compact safety logic such as emergency stop chains, guard monitoring and safe stop requests, not for large general-purpose programs.

Delta states that the safety controller and safety I/O modules can be placed directly to the right of an AX-5 standard controller or of a remote EtherCAT coupler, where the EtherCAT master can be one of the AX series motion controllers. The module is programmed in the same DIADesigner-AX environment as the rest of the AX-5 system, so the safety and standard parts of a machine stay in one project.

Where the AX-500SC00-0S fits in the system

Typical architecture is an AX-5 standard CPU such as AX-516EB0MB1T/P, AX-532EB0MB1T/P or AX-564EB0MB1T/P at the head of the station, the safety CPU immediately to its right, and safety I/O modules or a remote EtherCAT coupler beyond it. The manufacturer also states that the safety controller can cooperate with other Delta safety products, such as safety drives and robots, as well as third-party safety devices, so that safety synchronization works across systems.

Selection and ordering checklist for the AX-500SC00-0S

  • Confirm that the machine uses an AX-5 standard CPU or an EtherCAT coupler as the neighbouring head module.
  • Count safety inputs and outputs and check them against the 256 point limit and the 64 FSoE slave limit.
  • Compare the required safety level of each function (SIL 3 / PL e / Category 4) with your risk assessment.
  • Confirm the DIADesigner-AX version available to your engineers.
  • Order the matching safety I/O modules and terminal accessories in the same enquiry.

Reading the AX-500SC00-0S figures in a safety calculation

Three of the published values are used most often. PFHD of 2.51 E-10 is the probability of dangerous failure per hour that goes into a high-demand or continuous-mode safety function. PFDavg of 2.14 E-5 is the average probability of failure on demand, used for low-demand functions. MTTFd of 99.8 years feeds the ISO 13849-1 calculation together with diagnostic coverage of 99% or more. The module is a Type B subsystem element with hardware fault tolerance of 1, so the remaining devices in the loop (sensors, safety I/O, contactors or drives) must be evaluated separately and added to the result.

Installation, validation and maintenance

The module is only 12 mm wide and weighs 70 g, so panel space is rarely the constraint, but the removable 16-terminal block and the safety wiring deserve a clear labelling scheme. After wiring, perform a documented validation of every safety function: trigger each emergency stop and guard, confirm the safe state, and record the result. Any change to the safety program or the hardware requires re-validation. The proof test interval published by the manufacturer is 20 years or more, but plant procedures may require shorter functional checks.

Keep the safety program and its checksum in the project archive, and keep a spare module of the same part number for critical machines.

Typical applications in Oman and the GCC

Delta lists industrial robotics, woodworking, printing, packaging and electronics assembly. In Oman and the GCC, the AX-500SC00-0S is relevant to OEM machine builders and plants that add guarding and emergency-stop functions to packaging lines, robot cells and assembly stations. Cabinet cooling and dust control remain important in the regional climate.

Information to send with an RFQ

  • Part number AX-500SC00-0S and quantity.
  • Standard CPU in use (model string) and any EtherCAT coupler.
  • Number of safety I/O points and FSoE slaves.
  • Target safety level and the standard the machine is certified to.
  • Delivery location and required date.

Documents and quotation

Send us the part number and the machine configuration, and we will confirm which documents are available for the AX-500SC00-0S and quote the module together with the matching safety I/O.

Seven Star LLC is an independent supplier in Muscat and does not claim to be an official channel of the manufacturer.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Delta Electronics is a Taiwanese maker of power and automation products, founded in April 1971 by Bruce Cheng with 15 employees in a small factory in Sinjhuang, Taipei County. Its first products were TV deflection coils and electronic components; it later became a leading maker of switching power supplies and added drives, PLCs and HMIs for industrial automation. Delta is headquartered in Neihu, Taipei, and listed on the Taiwan Stock Exchange.

Seven Star LLC lists the Delta DVP04AD-S2 analog input module and the ESR-48/30D rectifier module, and sources Delta PLC modules and power parts for panel builders and maintenance teams in Oman and the GCC.

Delta company profile

Founded April 1971, Sinjhuang, Taipei County, Taiwan
Founder Bruce C.H. Cheng
First products TV deflection coils and electronic components
Headquarters Neihu District, Taipei, Taiwan
Listing Taiwan Stock Exchange (2308)
Product families DVP and AS series PLCs, C2000 Plus, CP2000, CH2000, MH300 and ME300 AC motor drives, REG2000 regenerative units, DIN Pro and DIN Eco DIN-rail power supplies, HMIs and servo systems

Milestones

  • 1971: Bruce Cheng founds Delta with 15 employees.
  • 1975: Delta is reorganised as a company limited by shares.
  • 2021: Delta marks 50 years.

Delta PLC families and the DVP slim line

Delta's controller program runs from the DVP series through the modular AS series to the AH series. Inside the DVP series, the slim CPUs (among them DVP-SS2, SA2, SX2, SV2 and SE) take slim expansion modules on their right side. The DVP04AD-S2 is one of these: a four-channel analog input module for voltage or current signals, which the CPU reads with FROM and TO instructions.

Delta products we list

Family Examples
AC Drives C2000 Plus High Performance Vector Contr…, CH2000 Heavy Duty Vector Control Drive f…, CP2000 Fan and Pump Vector Control Drive, ME300 Basic Compact AC Motor Drive, MH300 High Performance Compact Vector Co…, MS300 Standard Compact AC Motor Drive, REG2000 Power Regenerative Unit
PLC & I/O Cards AS Series Compact Modular Mid-Range PLC…, DVP Series Programmable Logic Controller…, DVP04AD-S2 DVP-S Series 4-Channel Analog…
Power Modules DIN Eco Series 3-Phase DIN Rail Power Su…, DIN Pro Series Single-Phase DIN Rail Pow…, ESR-48/30D Rectifier Module Power Supply

Ordering Delta parts: what we need

For PLC modules, send the complete type from the side label, including the suffix, and the CPU model it will join. For a rectifier module, send the type, the DC output voltage and current, the AC input, and the model of the power shelf or system it plugs into.

Facts checked against Delta's own 50th anniversary timeline (delta50.deltaww.com), October 2026.

FAQ

Questions about the Delta AX-500SC00-0S AX-5 Safety CPU Module

Answers from our engineering team on installation, compatibility and integration.

01What safety level does the AX-500SC00-0S reach?
Delta lists SIL 3 (IEC 61508, IEC 62061) and Performance Level e, Category 4 (ISO 13849-1). The overall level of a machine also depends on the connected devices and the safety function design.
02How many safety I/O points can the AX-500SC00-0S handle?
The published maximum is 256 safety I/O points and up to 64 FSoE slaves. Program capacity is 256 Byte, so it is suited to compact safety logic.
03Can the AX-500SC00-0S work without an AX-5 standard CPU?
Delta describes it as placed to the right of an AX-5 standard controller or a remote EtherCAT coupler, where the EtherCAT master is one of the AX series motion controllers. It is not a stand-alone PLC.
04What are the dimensions and weight of the AX-500SC00-0S?
12 mm wide, 100 mm high and 80 mm deep, with a weight of 70 g and a removable 16-terminal block.
05Which software programs the AX-500SC00-0S?
DIADesigner-AX, the same engineering environment used for the AX-5 standard controllers.