Brand: Endress+Hauser (E & H)
Endress+Hauser FMR62B Micropilot Flanged Radar Level Sensor
Description
Endress+Hauser FMR62B 80 GHz flanged radar for demanding liquid tanks
The Endress+Hauser FMR62B is the premium flanged Micropilot radar for continuous, non-contact level measurement of liquids, pastes and sludges. Three antenna families are offered: a 316L horn with ceramic antenna and graphite seal, a PTFE drip-off antenna, and a PTFE cladded flush-mount antenna in 50 or 80 mm. With the horn version the FMR62B covers –196 to +450 °C and vacuum to 160 bar, with a maximum range of 80 m, and every version provides 4-20 mA HART at about 80 GHz.
Seven Star LLC, an independent supplier in Muscat, supplies the FMR62B in Oman and the GCC for refinery, gas processing, LNG, power and chemical tanks. The FMR62B suits high pressure, cryogenic, hot or corrosive services where the simpler FMR60B reaches its limits.
FMR62B technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / FMR62B (Micropilot, HART version) |
| Measuring principle | Free-space radar, approx. 80 GHz, time of flight |
| Antenna and maximum range | Horn 316L 65 mm: 80 m; PTFE drip-off 50 mm: 50 m; PTFE cladded flush 50 mm: 50 m; PTFE cladded flush 80 mm: 80 m |
| Accuracy | ±1 mm above 0.8 m; up to ±4 mm closer; non-repeatability ≤ 1 mm |
| Process temperature | Horn (graphite seal): –196 to +450 °C; drip-off: –40 to +200 °C; PTFE cladded: –196 to +200 °C |
| Process pressure | Horn: –1 to 160 bar; drip-off: –1 to 16 bar; PTFE cladded: –1 to 25 bar |
| Process connection | Flanges (EN 1092-1, ASME B16.5, JIS B2220) |
| Beam angle | Horn 4 degrees; drip-off 6 degrees; PTFE cladded flush mount 7 degrees |
| Ambient temperature | –40 to +85 °C without display (optional –50 or –60 °C versions with limited life) |
| Output | 4-20 mA passive with HART, NAMUR NE 43 default 3.8 to 20.5 mA |
| Supply voltage | 10.5 to 35 VDC (non-hazardous, Ex d, Ex e); 10.5 to 30 VDC (Ex i); 0.9 W max. |
| Enclosure | IP66/68, NEMA 4X/6P |
| Functional safety | SIL 2 and SIL 3 with homogeneous redundancy; guided proof test for SIL and WHG |
| Diagnostics | Heartbeat Technology, Radar Accuracy Index, Bluetooth with SmartBlue, HistoROM |
How the FMR62B antennas are chosen
The FMR62B measures by sending a narrow microwave beam to the liquid surface and timing the echo. What changes between versions is the antenna. The horn antenna has the narrowest beam, 4 degrees, so at 20 m distance it covers a circle of only about 1.4 m, and it is the right pick for tall tanks with ladders, pipes and heating coils. Its ceramic antenna and graphite seal let it work at 450 °C and 160 bar, or down to –196 °C for cryogenic liquids. The PTFE cladded flush-mount antenna presents a smooth PTFE face to the process, which suits corrosive products, steam service and small flanged nozzles. The drip-off antenna lets condensate run off in moderate-pressure tanks.
The datasheet gives a measuring range for each antenna in storage, buffer and agitated vessels, split by media group. For the horn antenna in a calm storage tank the values are 20 m for group A0 (εr 1.2 to 1.4), 36 m for group A, 45 m for group B, 58 m for group C and 72 m for group D, so the full 80 m is a best-case figure for strongly reflecting liquids. If the dielectric constant is unknown, assume group B.
FMR62B process envelope by antenna
| Antenna | Seal | Temperature | Pressure |
|---|---|---|---|
| Horn 316L, 65 mm | Graphite | –40 to +450 °C; –196 to +200 °C | –1 to 160 bar |
| Drip-off PTFE, 50 mm | FKM, EPDM, HNBR, FFKM | –40 to +200 °C depending on seal | –1 to 16 bar |
| Cladded flush PTFE, 50 mm | PTFE cladded | –196 to +200 °C; steam –20 to +200 °C | –1 to 25 bar |
| Cladded flush PTFE, 80 mm | PTFE cladded | –196 to +200 °C; steam –20 to +200 °C | –1 to 25 bar (0 to 25 bar above 100 °C on DN150 and larger flanges) |
Where the FMR62B fits and related Micropilot sensors
Within the Micropilot B-series the FMR60B is the thread-connected sensor for simple tanks, the FMR62B is the flanged high-end version for aggressive and high-pressure liquids, and the FMR63B is the hygienic version. The FMR43 is the compact hygienic sensor for small tanks. When the vapour phase absorbs microwaves (ammonia, VCM, acetone and similar), the maker recommends a guided radar such as the Levelflex or another principle. Typical loop partners are a HART-capable DCS or SIS input card, a safety barrier for Ex i versions, and the SmartBlue app for configuration at the tank.
FMR62B selection and ordering checklist
- Liquid, dielectric constant or media group, and risk of foam, deposits or heavy vapour.
- Tank height and surface condition, internals and nozzle size and length.
- Maximum and minimum process temperature, pressure, and steam or cryogenic service.
- Antenna (horn, drip-off, cladded flush) and flange standard, size and rating.
- Seal and wetted materials compatible with the medium.
- Housing, cable entry, display and Bluetooth.
- Hazardous-area approvals, SIL level, CRN or marine approvals if required.
FMR62B installation, commissioning and maintenance
Install the FMR62B with the antenna axis perpendicular to the surface and away from the filling stream. For the horn antenna the insertion hole must be larger than the horn, and the datasheet gives a separate procedure for holes between 42 and 66 mm. Keep internal fixtures out of the beam cone, and pay attention to the 10 mm safety margin before the tip of the antenna so that deposits or corrosion do not damage the end of the range.
Commissioning is guided through the display, HART or SmartBlue, with an interference echo map taken after installation. Because the sensor has a Radar Accuracy Index and Heartbeat Verification, the calibration interval can be extended and proof tests carried out without emptying the tank. Plan seal inspection with every major shutdown, especially on hot or steam services.
FMR62B applications in Oman and the GCC
In the Gulf, the FMR62B is typically specified on crude and product storage, separator and knock-out vessels, LPG and condensate bullets, chemical tanks, boiler feedwater and deaerators, and cryogenic storage. Ambient heat and direct sun at outdoor tanks, as well as dusty air, are well covered by the sealed IP66/68 housing and the ambient range of –40 to +85 °C. Tall tanks with internals benefit from the narrow 4 degree horn beam.
Information for an FMR62B RFQ
- Process liquid, temperature, pressure and dielectric constant.
- Tank height, nozzle size and flange standard and class.
- Antenna type and seal preference.
- Output, supply, display and approval requirements, including SIL.
- Quantity and delivery site.
Documents and quotation
The technical information datasheet for the Micropilot FMR62B with HART is attached on this page, including range tables, flange data and wiring.
Send your tank data with the FMR62B version you need, and Seven Star LLC will prepare a quotation.
Other Models in the Eh Micropilot Radar Range
Seven Star LLC supplies models from the Eh Micropilot Radar range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser FMR43 Micropilot Hygienic Radar Level Sensor | Level Instrumentation | View details |
| Endress+Hauser FMR60B Micropilot 80 GHz Radar Level Sensor | Level Instrumentation | View details |
| Endress+Hauser FMR62B Micropilot Flanged Radar Level Sensor | Level Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser FMR62B Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMR62B Micropilot Flanged Radar
Answers from our engineering team on installation, compatibility and integration.
01What is the Endress+Hauser FMR62B?
The FMR62B is a flanged 80 GHz Micropilot radar for non-contact level measurement of liquids, pastes and sludges, with horn, drip-off or PTFE cladded flush-mount antennas and a 4-20 mA HART output.
02What temperature and pressure can the FMR62B handle?
The horn antenna with graphite seal covers -196 to +450 C and -1 to 160 bar. The PTFE cladded antennas are rated to 25 bar and the drip-off antenna to 16 bar, with temperatures up to 200 C.
03How far does the FMR62B measure?
The maximum range is 80 m for the 65 mm horn and the 80 mm cladded antenna, and 50 m for the 50 mm antennas. In practice the range depends on the dielectric constant and vessel type.
04What beam angle does the FMR62B have?
The horn antenna has a 4 degree beam, the drip-off antenna 6 degrees and the cladded flush-mount antenna 7 degrees. A narrow beam helps in tanks with many internals.
05Does the FMR62B support SIL applications?
Yes, the device is designed to SIL 2 under IEC 61508, with SIL 3 for homogeneous redundancy, and includes guided proof testing for SIL and WHG, depending on the version ordered.