Yokogawa UT35A / UT32A Digital Indicating Controller

Description

A universal-input PID controller with a colour display and a ladder sequence

The Yokogawa UT35A (96 x 96 mm) and UT32A (48 x 96 mm) are single-loop digital indicating controllers from the UTAdvanced series. Each has a 14-segment colour LCD with a PV display that can change colour on alarm, a guide display that shows parameter names, navigation keys, a 200 ms control period and a built-in ladder sequence function (up to 300 steps) that handles simple interlocks without an external PLC. The case is only 65 mm deep behind the panel, and the front is rated IP66 (NEMA 4, hose-down test only).

Typical duty is temperature, pressure or flow control on furnaces, ovens, dryers, heat-treatment lines, boilers and skid-mounted packages. Control types are PID, ON/OFF, two-position two-level and heating/cooling control, with Super and Super 2 functions that suppress overshoot and hunting, four target setpoints with four PID sets, and auto-tuning in Normal or Stable mode.

Technical specifications

Parameter Specification
Models UT35A (96 x 96 mm), UT32A (48 x 96 mm)
Control Single loop; PID, ON/OFF, two-position, heating/cooling; control period 200 ms
Display 5-digit 14-segment active colour LCD (white/red); character height 21.5 mm (UT35A), 13 mm (UT32A)
Universal input 1 point: thermocouple, RTD, DC voltage, DC current
Input accuracy +/-0.1% of instrument range +/-1 digit (most ranges, see datasheet table)
Control output Relay (1c) or 4-20/0-20 mA DC or voltage pulse; heating/cooling 2 x 1a relay
Alarm outputs Up to 3 relays (1a), 4 alarm settings, up to 8 alarm output points by model
Contact I/O 2 DIs and 3 DOs standard; up to 7 DIs and 8 DOs (UT35A)
Ladder sequence 300 steps; 13 basic and 73 application commands
Communication RS-485, Ethernet, CC-Link, PROFIBUS-DP, DeviceNet (UT32A: RS-485, CC-Link)
Supply 100-240 V AC; 24 V AC/DC with /DC; 18 VA (UT35A)
Front panel protection IP66; NEMA 4 (hose-down test only)
Operating temperature -10 to 50 C; 20 to 90% RH
Mounting Panel; cutout 92 x 92 mm (UT35A); depth 65 mm; weight 0.5 kg or less
Standards IEC/EN 61010-1 (CE), CSA, UL 61010-1; EN 61326-1 Class A

Inputs, outputs and communication

The single universal input accepts thermocouples (K, J, T, B, S, R, N, E, L, U, W, Platinel 2, PR20-40, W97Re3-W75Re25), RTDs (JPt100 and Pt100, 3-wire) and standard signals of 0.4 to 2 V, 1 to 5 V, 4 to 20 mA, 0 to 2 V, 0 to 10 V, -10 to 20 mV and 0 to 20 mA. Accuracy is plus or minus 0.1 percent of the instrument range plus 1 digit for most thermocouple types above 0 C and for RTD and standard signals. Outputs are a control relay or 4-20 mA/voltage pulse output, a retransmission output or 15 V DC loop supply, 2 contact inputs and 3 relay alarm outputs, with extra contact I/O by option code.

Communication options are RS-485 (Modbus RTU/ASCII, PC link, ladder, peer-to-peer), Ethernet (Modbus/TCP with serial gateway), CC-Link, PROFIBUS-DP and DeviceNet, the last three with Modbus master function. The UT32A supports only RS-485 and CC-Link.

Model code and options

The model code for UT35A is Type 1 (basic control: -0 standard, -1 position proportional, -2 heating/cooling), Type 2 (functions: 0 none, 1 two extra DIs and DOs, 2 five extra DIs and DOs), Type 3 (open network: 0 none, 1 RS-485, 2 Ethernet, 3 CC-Link, 4 PROFIBUS-DP, 5 DeviceNet), display language (-1 English, -2 German, -3 French, -4 Spanish), case colour (0 white, 1 black) and the fixed code -00. Option codes are /LP 24 V DC loop power supply, /HA heater break alarm, /DC 24 V AC/DC supply, /CT coating, /CV terminal cover, /MDL DIN-rail mounting and /RSP non-isolated remote input. The /CT coating option removes the UL, CSA and CE conformity, and several options have combination limits, so verify the full code against the datasheet.

Installation and what to confirm before ordering

Panel cutout is 92 x 92 mm for the UT35A and 45 x 92 mm for the UT32A, weight is 0.5 kg or less and wiring is by M3 screw terminals. Supply is 100 to 240 V AC (18 VA for UT35A) or 24 V AC/DC with /DC. Operating temperature is -10 to 50 C (-10 to 40 C side by side), and the instrument should be warmed up for 30 minutes. Confirm the sensor type and range, whether you need heating/cooling or position-proportional output, the relay or current output for your actuator, communication protocol, panel size and any approval; the datasheet lists CE, UL and CSA. The attached file is the 14-page Yokogawa general specification GS 05P01D31-01EN. Related controllers in controllers and data acquisition include the larger-case UTAdvanced models. Send the full code for a quotation.

Datasheets & Documents
  • PDF Datasheet Yokogawa UT35A, UT32A digital indicating controller general specifications GS 05P01D31-01EN (14 pp) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa instruments are ordered by model and suffix code, a string such as EJX110A followed by option characters that fix span, materials and approvals. Founded in 1915 and headquartered in Tokyo, Yokogawa makes field instruments, process analyzers and the CENTUM control system used in refineries, gas plants and power stations.

Seven Star LLC is an independent supplier listing Yokogawa pressure transmitters, flowmeters, temperature transmitters, analyzers and CENTUM I/O modules for users in Oman and the GCC.

Yokogawa product families on this page

Pressure is covered by the DPharp transmitters: the EJX110A differential pressure transmitter, the EJX530A and EJA530E in-line gauge pressure transmitters and the EJX910A multivariable transmitter. The ADMAG AXW is the magnetic flowmeter line, and the YTA610 and YTA710 are temperature transmitters. Analyzers include the FLXA402 four-wire and FLXA21 two-wire liquid analyzers, the TDLS8000 tunable diode laser gas analyzer and spare parts for zirconia oxygen analyzers, such as the E7042UD cell assembly kit for the ZR22 detector. Control hardware includes CENTUM VP I/O modules like the ADV161 digital input module and the YS1700 programmable indicating controller.

Where Yokogawa instruments are used

EJA and EJX transmitters measure pressure, level and DP flow throughout oil and gas, chemical and power plants. Zirconia oxygen analyzers and the TDLS8000 are used for combustion control on boilers and fired heaters. FLXA analyzers monitor pH, conductivity and dissolved oxygen in water and process streams, and CENTUM modules are bought as replacements for running control systems.

Ordering Yokogawa parts: what we need

Send the model and suffix code and the serial number from the nameplate, and for CENTUM modules the style code as well. For transmitters without a code we need span, output protocol, wetted materials, process connection, housing and the approval required. For oxygen analyzer spare parts give the detector and converter models, for example ZR22G and ZR402G, and the part number.

Frequently Asked Questions

What size is the UT35A?
96 x 96 mm with a depth of 65 mm behind the panel; the UT32A is 48 x 96 mm.
Does it have a built-in sequence function?
Yes. A ladder sequence function of up to 300 steps is standard.
Which communications are available?
RS-485, Ethernet, CC-Link, PROFIBUS-DP and DeviceNet on the UT35A; the UT32A supports RS-485 and CC-Link.
What is the control period?
200 ms.
What front-panel protection does it have?
IP66, with NEMA 4 rating for the hose-down test only.