Yokogawa UT52A-000-10-00 48 x 96 mm Digital Indicating Controller

Description

Yokogawa UT52A-000-10-00 overview

The Yokogawa UT52A-000-10-00 is the narrow, vertical-format member of the Yokogawa UTAdvanced digital indicating controller family, measuring 48 mm wide and 96 mm high with a depth of 65 mm behind the panel. It shares its menu structure, ladder sequence function and universal input with the larger 96 x 96 mm UT55A, but its case allows two or more controllers to sit side by side in a compact instrument panel.

In the order code Yokogawa UT52A-000-10-00, -0 is the standard control type, the following 0 and 0 select no extra function block and no open network, -1 selects English and 0 selects a white case, with -00 as the fixed code. Exact order strings matter on this model, because the Type 2 and Type 3 choices for the UT52A are shorter than for the UT55A and the CC-Link option is allowed only with certain combinations.

This page describes the UT52A-000-10-00 as published in the manufacturer’s general specification GS 05P01C31, written in our own words for buyers who need to identify the exact part. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We supply against the part number you provide and do not substitute without your written agreement.

Key features of the UT52A-000-10-00

  • Same 14-segment color LCD concept as the UT55A, with a 13.0 mm character height on the PV display suited to the narrow case.
  • Universal input for thermocouple, RTD, DC voltage and DC current with the same input ranges as the larger model.
  • Ladder sequence function included as standard, with up to 500 steps and as many as 5 digital inputs and 5 digital outputs available to the ladder program.
  • Control type selection: standard, position proportional or heating/cooling, with PID, ON/OFF, sample PI and other control functions.
  • Retransmission output or 15 V DC loop power supply plus 3 contact inputs and 3 contact outputs in the basic form.
  • Narrow 48 mm width for dense panel layouts, with a panel cutout of 45 mm x 92 mm.
  • IP66 front panel protection (not applicable to side-by-side close mounting).

UT52A-000-10-00 technical specifications

Item Specification
Model UT52A, digital indicating controller, panel mounting
Order code UT52A-000-10-00 (Type 1 -0, Type 2 0, Type 3 0, language -1, case color 0, fixed code -00)
Case size 48 mm wide x 96 mm high x 65 mm deep from the panel surface
Panel cutout 45 mm x 92 mm (width x height)
Weight 0.5 kg or less
Display 5-digit 14-segment color LCD PV display, character height 13.0 mm
Universal input 1 point: thermocouple, RTD, DC voltage, DC current
Inputs and outputs (code x0x) 1 analog input, 1 analog output, 3 contact inputs, 3 contact outputs
Ladder capacity Up to 500 steps; up to 5 digital inputs and 5 digital outputs for the ladder
Relay output (control) UT52A control relay: 3 A at 240 V AC or 3 A at 30 V DC (resistance load)
Analog output 4 to 20 mA DC or 0 to 20 mA DC, load 600 ohm or less
Loop power supply 15 V DC, 14.5 to 18.0 V DC, about 21 mA maximum
Power supply 100 to 240 V AC (+10 percent / -15 percent), 50/60 Hz; 24 V AC/DC with option /DC
Power consumption 15 VA
Ambient temperature -10 to 50 degC (side-by-side mounting -10 to 40 degC)
Ambient humidity 20 to 90 percent RH, no condensation
Front protection IP66, NEMA 4 (hose-down test only)
Communication options RS-485 (Type 2 code 1) and CC-Link (Type 3 code 3, only with Type 1 -0 and Type 2 0)

The values above are taken from the manufacturer’s general specification for the UT55A and UT52A digital indicating controllers. Treat the document as the controlling reference and confirm every figure against the latest revision before final design, because the manufacturer may change specifications without notice.

Typical applications in oil and gas, utilities, water and manufacturing

Controllers of this class suit oil and gas package skids, gas-fired heaters and reboilers, glycol and amine units, desalination and water-treatment heating and dosing loops, packaging and food lines, laboratory furnaces and ovens, and pump-house or compressor utilities across Oman and the GCC. Small loops do not justify a DCS point, yet they must hold a setpoint, raise an alarm and share data with a PLC or SCADA system.

A buyer who already has the UT52A-000-10-00 installed usually wants the same suffix code again, which keeps panel cutouts, terminal layouts, spare stocks and documentation unchanged. That is the main reason this exact part number is searched for rather than a generic description.

Selection and compatibility notes for the UT52A-000-10-00

  • For the UT52A, Type 2 offers codes 0 to 3 (none; remote input, 1 DI and RS-485; remote input and 1 DI; 2 additional DIs and 2 DOs), and Type 3 offers only 0 or 3 (CC-Link).
  • Choose the UT55A instead when you need cascade or other multi-input control modes, since several control modes require a remote auxiliary analog input and a larger number of I/O points.
  • Options /DR, /LP, /HA, /DC, /CT and /MDL have restrictions tied to the Type 1 to Type 3 codes; state them in the enquiry.
  • Check panel space: 45 x 92 mm cutouts cannot accept the 96 x 96 mm UT55A without modification.

The terminal cover for the UT52A is a separate spare listed as model UTAP002 in the same general specification.

Installation and commissioning

Mount the controller from the front of the panel using the supplied upper and lower brackets in a cutout of the size listed above, within the panel thickness range in the general specification. Keep the mounting angle within 30 degrees above horizontal with no downward tilt. Wire signals and power to the M3 screw terminals with square washers, keep sensor wiring away from power cables, and observe the allowable wiring resistance for RTD inputs. Allow a warm-up time of 30 minutes before judging accuracy, set the input type and range, configure alarms and the control mode, and run auto-tuning once the process is stable.

Before energising a UT52A-000-10-00 in a hazardous or critical service, confirm that the selected variant, enclosure rating and any approvals you require are covered by the order string and by your site rules.

Maintenance and spare parts

The controller has no moving parts and stores parameters in nonvolatile memory. Routine care means checking terminals for tightness, keeping the front panel and vents clean, verifying input accuracy against a calibrator at intervals set by your quality system, and exercising alarm and relay outputs. Keep a record of parameters, ladder programs and the order string so that a replacement unit can be configured quickly. Note that relay contacts have a finite life under heavy loads, so heavily switched outputs may be better driven through an external relay or solid-state device.

Related products and ordering notes

The UT52A-000-10-00 belongs to the UT55A and UT52A digital indicating controllers group. Related family members, modules, software and accessories are listed in the same general specification, and we can quote them together with the UT52A-000-10-00 when you need a complete panel or loop. Because many Yokogawa instruments are specified by long suffix strings, always quote the complete order code, the option codes, the quantity and the destination. If your installed unit is an older revision, send a nameplate photograph or the exact code printed on it so that compatibility can be checked before any quotation is issued.

Frequently asked questions about the UT52A-000-10-00

  • What is the difference between UT52A-000-10-00 and the UT55A? The UT52A is the narrow 48 x 96 mm case with a 13.0 mm PV character height and fewer I/O and network choices; the UT55A is 96 x 96 mm with a 21.5 mm character height and more I/O combinations.
  • What is the panel cutout? The panel cutout stated in the general specification is 45 mm wide by 92 mm high, with mounting brackets supplied for upper and lower mounting.
  • Is a ladder program included? Yes, a ladder sequence function with up to 500 steps is part of the standard function set, programmed with the separately sold LL50A software.
  • Which network is possible on this code? With Type 3 equal to 0 as in UT52A-000-10-00 there is no open network; CC-Link requires Type 3 equal to 3, and RS-485 is obtained through the Type 2 code 1.
  • How do I request a quotation? Send the complete order string UT52A-000-10-00 with options, the quantity and the delivery destination, and we will respond to the RFQ with availability.

Documents and quotation

The manufacturer’s datasheet for the UT52A-000-10-00 is available on this page for download and lists the model and suffix codes, specifications and dimensions in full. To request a quotation, send the RFQ with the part number UT52A-000-10-00, the quantity, any option codes and the delivery destination in Oman or the GCC. Our team will confirm availability, lead time and commercial terms for the UT52A-000-10-00 by return.

Other Models in the UT55A And UT52A Digital Indicating Controllers Range

Seven Star LLC supplies models from the UT55A And UT52A Digital Indicating Controllers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa UT55A-000-10-00 Digital Indicating ControllerControllers & Data AcquisitionView details
Yokogawa UT52A-000-10-00 48 x 96 mm Digital Indicating ControllerControllers & Data AcquisitionYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa UT52A-000-10-00 48 x 96 mm Digital Indicating Controller Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa UT52A-000-10-00 48 x 96 mm Digital

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between UT52A-000-10-00 and the UT55A?
The UT52A is the narrow 48 x 96 mm case with a 13.0 mm PV character height and fewer I/O and network choices; the UT55A is 96 x 96 mm with a 21.5 mm character height and more I/O combinations.
02What is the panel cutout?
The panel cutout stated in the general specification is 45 mm wide by 92 mm high, with mounting brackets supplied for upper and lower mounting.
03Is a ladder program included?
Yes, a ladder sequence function with up to 500 steps is part of the standard function set, programmed with the separately sold LL50A software.
04Which network is possible on this code?
With Type 3 equal to 0 as in UT52A-000-10-00 there is no open network; CC-Link requires Type 3 equal to 3, and RS-485 is obtained through the Type 2 code 1.
05How do I request a quotation?
Send the complete order string UT52A-000-10-00 with options, the quantity and the delivery destination, and we will respond to the RFQ with availability.