Brand:

Yokogawa DX3020-3-4-2 20-Channel Horizontal Daqstation

Description

Yokogawa DX3020-3-4-2 is the twenty-channel version of the DX3000 Daqstation, a horizontally formatted panel recorder that puts a 10.4-inch color LCD next to a full keypad and a row of function keys. Where the DX2000T touch recorders rely on a touch overlay, this model gives operators physical keys and soft keys under the screen. The facts on this page come from Yokogawa General Specifications GS 04L75B01-01EN, third edition (November 2016).

Hardware profile of DX3020-3-4-2

  • Front format: 448 mm wide by 215 mm high, 234.2 mm deep (17.68 x 8.46 x 9.22 inch), steel case with an aluminum bezel.
  • Weight: about 7.24 kg without options for the DX3020 and DX3008; 6.96 kg for the DX3004 and DX3010; 7.52 kg for the DX3030.
  • Mounting: flush panel, panel thickness 2 to 26 mm, inclination downward up to 30 degrees.
  • Screen: 10.4-inch TFT color LCD, 640 x 480 pixels.
  • Memory: 400 MB internal (suffix -3) and a CF card with media (suffix -4).
  • Language: English, German and French with degF and summer/winter time (suffix -2).
  • Supply: 100 to 240 VAC, 50/60 Hz; 28 VA with the LCD off, 42 VA normal and 74 VA maximum at 100 VAC, rising to 38, 54 and 100 VA at 240 VAC.

Measurement capability of DX3020-3-4-2

All twenty channels of the DX3020-3-4-2 are universal. A channel can take DC voltage in seven ranges from 20 mV to 50 V plus 1-5 V, thermocouples (R, S, B, K, E, J, T, N, W, L, U, WRe), Pt100 or JPt100 RTDs, a digital contact or TTL level, or a current signal through an external shunt. The base scan interval of DX3020-3-4-2 is 1 s, with a fast mode at 125 ms; the four and eight channel models instead start at 125 ms and offer a 25 ms fast mode. Computations include differential between two channels, linear scaling between minus 30000 and 30000, square root with a low-level cut of 0 to 5 percent, and moving average of 2 to 400 cycles.

Log input mode and simulation

Two functions of the DX3020-3-4-2 are specific to the DX3000 line. Log input mode lets a DC voltage channel be displayed on a logarithmic scale between 1.0E-15 and 1.0E+15, a maximum of 15 decades. The simulation group offers display freeze, which stops the time, trend, digital values and bar graph from updating, and a memory and trend clear function, both controllable through key operation, event action or communication. Operators commissioning a DX3020-3-4-2 can therefore hold a screen for a photo or a test without disturbing the recording.

How DX3020-3-4-2 differs from other DX3000 variants

The five DX3000 models, of which the DX3020-3-4-2 is one, share the front, the screen and the software. They split on channel count: DX3004 has four channels, DX3008 eight, DX3010 ten, DX3020-3-4-2 (DX3020) twenty and DX3030 thirty. Scan interval separates the first two (125 ms) from the other three (1 s). The /N2 three-leg isolated RTD, /MC1 external input and /BT2 multi-batch options are reserved for the DX3010, DX3020 and DX3030, so this twenty-channel unit can use all three; the four and eight channel models cannot. Mass climbs from 6.96 kg to 7.52 kg across the range.

Model code Channels Base interval Weight (kg)
DX3004 4 125 ms 6.96
DX3008 8 125 ms 7.24
DX3010 10 1 s 6.96
DX3020 20 1 s 7.24
DX3030 30 1 s 7.52

Network and protocol notes

The Ethernet port of the DX3020-3-4-2 supports e-mail alerts, a web monitor, FTP file transfer and both Modbus/TCP client and server operation, with IP filtering for Modbus access. The protocol list in the datasheet reads TCP, UDP, IP, ICMP, ARP, DHCP, HTTP, FTP, SMTP, SNTP, Modbus, DX private and EtherNet/IP; the EtherNet/IP server exposes measurement and computation channel data for reading and external or communication input channels for reading and writing. Serial communication is optional through /C2 (RS-232) or /C3 (RS-422A or RS-485), and the two cannot be fitted together.

Where this recorder fits in Oman and GCC plants

The wide format is made for horizontal instrument panels and compressor or turbine control cabinets where the vertical room is limited. A DX3020-3-4-2 can log 20 points of casing, bearing and exhaust temperatures, or archive process values from a PLC through Modbus or EtherNet/IP, which makes it a practical evidence log beside a control system in oil and gas, power generation and water treatment. The horizontal 448 x 215 mm front also suits a long, shallow cut-out.

Ordering the options correctly

Relay outputs on a DX3020-3-4-2 come as /A3 (6 points), /A4 (12) or /A5 (24), or /F2 for a fail output plus 22 alarm points; these cannot be mixed. The /F1 fail or status relay cannot be combined with /A5 or /F2. Transmitter power is /TPS4 or /TPS8, 24 VDC for four or eight loops, and it cannot accompany /A5 or /F2. Further codes: /M1 mathematics, /N1 Cu10 and Cu25 inputs, /N3 extended input types such as PR40-20 and Pt50, /R1 remote control, /USB1, /CC1 calibration correction and /AS1 advanced security. Software for the DX3020-3-4-2 is DXA120-S2 DAQSTANDARD, with DXA170 and DXA250 as optional packages. When you request a DX3020-3-4-2 quotation, quote the suffix and every slash code together.

Setup and care of DX3020-3-4-2

Wire supply and signals in accordance with the installation category noted in the datasheet (installation category II, pollution degree 2, measurement category II), keep the ambient between 0 and 50 C with 20 to 80 percent RH at 5 to 40 C, and avoid vibration beyond the stated limits. The lithium battery behind the memory is rated at about ten years at room temperature. Store a DX3020-3-4-2 setup file on the CF card, rehearse the display freeze function, and verify the Modbus register map with the control system before handover. A final note on DX3020-3-4-2: the time zone and daylight-saving rules are configurable, so set them before the first recording.

Documents and quotation

The Yokogawa datasheet GS 04L75B01-01EN accompanies this page. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. For availability and a quotation, send an RFQ naming DX3020-3-4-2, the option codes you need and the quantity.

Datasheets & Documents
  • PDF Datasheet Yokogawa DX3020-3-4-2 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa DX3020-3-4-2 20-Channel Horizontal

Answers from our engineering team on installation, compatibility and integration.

01What makes the DX3020-3-4-2 different from the DX2000T recorders?
It uses a wide 448 x 215 mm front with an aluminum bezel, a hardware keypad and function keys, adds log input mode and an EtherNet/IP server, and is offered in 4, 8, 10, 20 and 30 channel versions only.
02What is the log input mode on the DX3020-3-4-2?
It converts a DC voltage input (20 mV to 50 V ranges) to a logarithmic scale and displays it, with a selectable scale range of 1.0E-15 to 1.0E+15, up to 15 decades.
03Which communication protocols does the DX3020-3-4-2 support?
The datasheet lists TCP, UDP, IP, ICMP, ARP, DHCP, HTTP, FTP, SMTP, SNTP, Modbus, the DX private protocol and EtherNet/IP, with optional RS-232 or RS-422A/485 serial ports.
04What is the cut-out size and weight of the DX3020-3-4-2?
The housing is 448 mm wide, 215 mm high and 234.2 mm deep and the DX3020 weighs about 7.24 kg without options, mounted flush in a panel 2 to 26 mm thick.
05Does the DX3020-3-4-2 offer a 24 V supply or VGA output?
No. The DX3000 option list has no /P1 24 V supply and no /D5 VGA output; the supply is 100 to 240 VAC (90 to 132 or 180 to 264 VAC allowed) at 50/60 Hz.