Yokogawa UP35A-000-10-00 Program Controller (Ramp/Soak)
Description
Yokogawa UP35A-000-10-00 overview
The Yokogawa UP35A-000-10-00 is a 96 x 96 mm program controller from the Yokogawa UTAdvanced range. Where a standard indicating controller holds one setpoint, a program controller moves the setpoint over time according to a stored pattern of ramps and soaks, which is the basis of heat-treatment, curing, drying, tempering and furnace cycles.
In the order code Yokogawa UP35A-000-10-00, -0 is the standard control type, the following 0 and 0 select no additional contact I/O block and no open network, -1 selects an English guide display, 0 selects a white case and -00 is the fixed code. The base model stores 2 program patterns of 20 segments in total; the /AP option adds 2 further patterns and 20 further segments, so the model, not only the case size, determines how many recipes the controller can hold.
This page describes the UP35A-000-10-00 as published in the manufacturer’s general specification GS 05P02D41, written in our own words for buyers who need to identify the exact part. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We supply against the part number you provide and do not substitute without your written agreement.
Key features of the UP35A-000-10-00
- Program setpoint function: each pattern is built from program segments defined by segment time or slope, with repeats, start and stop, and status (event) outputs.
- Two program patterns and 20 program segments as standard; four patterns and 40 segments with option /AP, up to 20 segments per pattern.
- 14-segment active color LCD with 21.5 mm PV character height and navigation keys, in a case only 65 mm deep.
- Universal input with thermocouple, RTD, DC voltage and DC current, plus retransmission output or 15 V DC loop supply.
- Basic configuration of 3 contact inputs and 3 contact outputs, with extra I/O through the Type 2 code.
- Ladder sequence function as standard (up to 300 steps) and PID, ON/OFF and heating/cooling control types.
- IP66 front panel protection and NEMA 4 (hose-down test only) except side-by-side mounting.
UP35A-000-10-00 technical specifications
| Item | Specification |
|---|---|
| Model | UP35A, program controller, panel mounting |
| Order code | UP35A-000-10-00 (Type 1 -0, Type 2 0, Type 3 0, language -1, case color 0, fixed code -00) |
| Case size | 96 mm x 96 mm x 65 mm deep from the panel surface |
| Weight | 0.5 kg or less |
| Program capacity | 2 patterns / 20 segments; 4 patterns / 40 segments with /AP; max 20 segments per pattern |
| Segment time setting | 0.00 to 999.59 (hour.minute or minute.second) |
| Control period | 200 ms |
| Display | 5-digit 14-segment color LCD, PV character height 21.5 mm |
| Universal input | 1 point; type K accuracy 0.1 percent of instrument range plus 1 digit for 0 degC or more |
| Inputs and outputs (code x0x) | 1 analog input, 1 analog output, 3 contact inputs, 3 contact outputs |
| Ladder capacity | Up to 300 steps |
| Power supply | 100 to 240 V AC, 50/60 Hz; 24 V AC/DC with option /DC |
| Power consumption | 18 VA (24 V DC: 9 VA, 24 V AC: 14 VA with /DC) |
| Front protection | IP66, NEMA 4 (hose-down test only) |
The values above are taken from the manufacturer’s general specification for the UP35A and UP32A program controllers. Treat the document as the controlling reference and confirm every figure against the latest revision before final design, because the manufacturer may change specifications without notice.
Typical applications in oil and gas, utilities, water and manufacturing
Program controllers suit heat-treatment furnaces, tempering and curing ovens, kilns, drying chambers, environmental test chambers and batch heating processes in workshops, fabrication yards, laboratories and manufacturing plants across Oman and the GCC, wherever the setpoint must follow a time-based ramp and soak profile rather than stay fixed.
A buyer who already has the UP35A-000-10-00 installed usually wants the same suffix code again, which keeps panel cutouts, terminal layouts, spare stocks and documentation unchanged. That is the main reason this exact part number is searched for rather than a generic description.
Selection and compatibility notes for the UP35A-000-10-00
- Type 1: -0 standard, -1 position proportional, -2 heating/cooling. Type 2: 0 none, 1 for five additional DIs and DOs.
- Type 3 selects the open network (0 none, 1 RS-485, 2 Ethernet, 3 CC-Link, 4 PROFIBUS-DP, 5 DeviceNet).
- Options: /AP (extra patterns and segments), /HA (heater break alarm, only with Type 1 -0 or -2), /DC (24 V AC/DC), /CT (coating), /CV (terminal cover).
- The 48 x 96 mm UP32A is covered in the same general specification and offers a smaller I/O and network choice.
Ladder programs and parameters can be prepared with the separately sold LL50A parameter setting software.
Installation and commissioning
Mount the controller from the front of the panel using the supplied upper and lower brackets in a cutout of the size listed above, within the panel thickness range in the general specification. Keep the mounting angle within 30 degrees above horizontal with no downward tilt. Wire signals and power to the M3 screw terminals with square washers, keep sensor wiring away from power cables, and observe the allowable wiring resistance for RTD inputs. Allow a warm-up time of 30 minutes before judging accuracy, set the input type and range, configure alarms and the control mode, and run auto-tuning once the process is stable.
Before energising a UP35A-000-10-00 in a hazardous or critical service, confirm that the selected variant, enclosure rating and any approvals you require are covered by the order string and by your site rules.
Maintenance and spare parts
The controller has no moving parts and stores parameters in nonvolatile memory. Routine care means checking terminals for tightness, keeping the front panel and vents clean, verifying input accuracy against a calibrator at intervals set by your quality system, and exercising alarm and relay outputs. Keep a record of parameters, ladder programs and the order string so that a replacement unit can be configured quickly. Note that relay contacts have a finite life under heavy loads, so heavily switched outputs may be better driven through an external relay or solid-state device.
Related products and ordering notes
The UP35A-000-10-00 belongs to the UP35A and UP32A program controllers group. Related family members, modules, software and accessories are listed in the same general specification, and we can quote them together with the UP35A-000-10-00 when you need a complete panel or loop. Because many Yokogawa instruments are specified by long suffix strings, always quote the complete order code, the option codes, the quantity and the destination. If your installed unit is an older revision, send a nameplate photograph or the exact code printed on it so that compatibility can be checked before any quotation is issued.
Frequently asked questions about the UP35A-000-10-00
- How many program patterns does UP35A-000-10-00 store? The base model stores 2 program patterns and 20 program segments in total. Adding option /AP raises this to 4 patterns and 40 segments, with a maximum of 20 segments per pattern.
- What is a program controller used for? It varies the setpoint over time following ramp and soak segments, which suits furnaces, ovens, dryers and curing or heat-treatment cycles.
- Is the UP35A-000-10-00 the same as a UT35A? They share the case, display and universal input, but the UP35A adds the program setpoint function, while the UT35A is a fixed-setpoint single-loop controller.
- Which power supply does it use? The standard supply is 100 to 240 V AC at 50/60 Hz. A 24 V AC/DC supply requires option code /DC.
- What should an RFQ contain? Send the exact order string UP35A-000-10-00, any option codes such as /AP, the quantity and the delivery destination in Oman or the GCC.
Documents and quotation
The manufacturer’s datasheet for the UP35A-000-10-00 is available on this page for download and lists the model and suffix codes, specifications and dimensions in full. To request a quotation, send the RFQ with the part number UP35A-000-10-00, the quantity, any option codes and the delivery destination in Oman or the GCC. Our team will confirm availability, lead time and commercial terms for the UP35A-000-10-00 by return.
See also: Yokogawa GX10 / GX20 Touch Screen Paperless Recorder.
Other Models in the UP35A And UP32A Program Controllers Range
Seven Star LLC supplies models from the UP35A And UP32A Program Controllers range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa UP35A-000-10-00 Program Controller (Ramp/Soak) | Controllers & Data Acquisition | You are viewing this model |
| Yokogawa UP32A-000-10-00 48 x 96 mm Program Controller | Controllers & Data Acquisition | View details |
Datasheets & Documents
- Datasheet Yokogawa UP35A-000-10-00 Program Controller (Ramp/Soak) Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa UP35A-000-10-00 Program Controller
Answers from our engineering team on installation, compatibility and integration.
01How many program patterns does UP35A-000-10-00 store?
The base model stores 2 program patterns and 20 program segments in total. Adding option /AP raises this to 4 patterns and 40 segments, with a maximum of 20 segments per pattern.
02What is a program controller used for?
It varies the setpoint over time following ramp and soak segments, which suits furnaces, ovens, dryers and curing or heat-treatment cycles.
03Is the UP35A-000-10-00 the same as a UT35A?
They share the case, display and universal input, but the UP35A adds the program setpoint function, while the UT35A is a fixed-setpoint single-loop controller.
04Which power supply does it use?
The standard supply is 100 to 240 V AC at 50/60 Hz. A 24 V AC/DC supply requires option code /DC.
05What should an RFQ contain?
Send the exact order string UP35A-000-10-00, any option codes such as /AP, the quantity and the delivery destination in Oman or the GCC.