- Automation & ControlView all 3,009 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa DX1012T-3-4-2 12-Channel Touch Daqstation Recorder
Description
The Yokogawa DX1012T-3-4-2 is a twelve-channel Daqstation from the DX1000T touch series: a panel-mounted instrument that draws live trends on a 5.7-inch color TFT screen, lets the operator work through an analog resistive touch panel, and writes measured data into 400 MB of internal flash memory and onto a CompactFlash card. The suffix of DX1012T-3-4-2 tells you what is in the box: internal memory of 400 MB, an external CF card that ships with its media, and an English, German and French interface with degF and daylight-saving support. This page is based on Yokogawa General Specifications GS 04L45B01-01EN, 9th edition, and every figure below comes from that document.
What the DX1012T-3-4-2 actually is
The DX1000T family covers two, four, six and twelve channel versions. The top of the range, the DX1012T-3-4-2 (DX1012T), keeps the 144 mm square bezel of its smaller siblings yet multiplexes twelve universal inputs. Each input can be set independently to DC voltage, thermocouple, resistance temperature detector or a contact signal, so a single recorder can watch furnace thermocouples, a 1-5 V pressure loop and a pump run contact at the same time. Data can leave the unit through Ethernet (e-mail notification, a web monitoring page, FTP file transfer and Modbus/TCP), through optional serial links, or by simply carrying the CF card to a PC, where the supplied conversion software turns the binary files into Excel, Lotus 1-2-3 or ASCII.
Key features of the DX1012T-3-4-2
- Twelve measurement channels, 1 s shortest interval, plus a 125 ms fast sampling mode that fixes A/D integration at 1.67 ms (600 Hz).
- A/D integration choices of 20 ms for 50 Hz, 16.7 ms for 60 Hz, 100 ms for the 6 and 12 channel models, or AUTO, which detects the supply frequency by itself.
- Touch operation of the operator menu, the FUNC key menu and trend history, with a password lock and a touch-position correction routine.
- Ten display groups of up to six channels each, with trend, digital and bar graph views and a choice of 24 trace colors on a white or black background.
- Alarms with up to four levels per channel: high, low, differential high and low, rate-of-change high and low, and delay high and low.
- Thirty internal switches that can be combined with AND or OR logic and, optionally, two, four or six relay outputs.
Technical specifications of the DX1012T-3-4-2
| Model / suffix | DX1012T-3-4-2 |
|---|---|
| Channels | 12 universal inputs |
| Display | 5.7-inch TFT color LCD, 320 x 240 pixels (VGA class), analog resistive touch |
| Measurement interval | 1 s, 2 s, 5 s; 125 ms in fast sampling mode |
| DC voltage ranges | 20 mV, 60 mV, 200 mV, 2 V, 6 V, 1-5 V, 20 V, 50 V |
| Thermocouple ranges | R/S 0 to 1760 C, B 0 to 1820 C, K minus 200 to 1370 C, N minus 270 to 1300 C, W 0 to 2315 C, WRe 0 to 2400 C |
| RTD ranges | Pt100 minus 200 to 600 C; JPt100 minus 200 to 550 C, 1 mA measuring current |
| Memory | 400 MB internal flash plus CF card |
| Mounting | Flush panel, 2 to 26 mm panel thickness, up to 30 degrees downward tilt |
| Dimensions | 144 W x 144 H x 224.1 D mm (228.5 mm with /H2 or /PM1) |
| Weight | About 2.9 kg without options |
| Front protection | IP32 type water and dust resistance, except side-by-side mounting |
| Supply | 100 to 240 VAC automatic switching, 50/60 Hz; 24 VDC/AC with /P1 |
| Power consumption | 100 VAC: 15 VA LCD off, 24 VA normal, 45 VA max; 240 VAC: 25, 32 and 60 VA |
| Operating ambient | 0 to 50 C, 20 to 80 percent RH at 5 to 40 C |
| Backup battery | Lithium cell holding setup data, about 10 years at room temperature |
How DX1012T-3-4-2 differs from other DX1000T variants
Three siblings share the same bezel and software, and the differences are concrete. The DX1002T and DX1004T scan every 125 ms and carry two or four inputs, while DX1012T-3-4-2 scans every second but handles twelve. The six and twelve channel units accept the 100 ms A/D integration setting, which the smaller two do not. Only the DX1006T and the DX1012T can take the /N2 three-leg isolated RTD option and the /BT2 multi-batch option. The 144 mm case is identical across the range, so a DX1012T-3-4-2 can replace a four-channel unit in an existing cut-out without enlarging the panel.
Typical applications in Oman and the GCC
Twelve channels in a single cut-out make the DX1012T-3-4-2 suit the multi-point jobs that keep appearing in Gulf plants. Boiler and heat-treatment furnaces fitted with a DX1012T-3-4-2 use the thermocouple types with burnout detection, which can be set to upscale or downscale for each channel. Desalination and water treatment skids record pressure and flow transmitters on the 1-5 V range with square root and linear scaling. Pasteurizer, cold store and warehouse logging benefits from the Pt100 inputs and from the CF card, which keeps a complete audit trail even if the network link is down. Utilities use the pulse input option to total energy or flow counts, and the transmitter supply option to power two or four loops directly from the recorder.
Selection and compatibility notes
Choose the options for the DX1012T-3-4-2 before ordering because several are mutually incompatible. The alarm output options /A1, /A2 and /A3 cannot be combined with one another, /A3 and /F1 cannot be specified together, and /PM1 rules out /A3, /M1, /R1 and both transmitter supplies. The serial interfaces /C2 and /C3 and the PROFIBUS-DP card /CP1 are alternatives. If the cabinet runs on 24 V, specify /P1; in that case a desktop version must use the /H5 code. Software is ordered separately: DXA120 DAQSTANDARD, optional DXA170 DAQStudio for custom screens, and DXA250 DAQManager. The advanced security option /AS1 adds user levels, operation logs and a signing workflow, a point worth settling for regulated food or pharmaceutical duties. Contact rating of the relay outputs is 250 VDC at 0.1 A or 250 VAC at 3 A, SPDT.
Installing and commissioning DX1012T-3-4-2
Mount the case vertically, or tilted downward by no more than 30 degrees, in a panel 2 to 26 mm thick. Keep the supply to the DX1012T-3-4-2 between 90 and 132 or 180 and 264 VAC; the recorder rides through interruptions shorter than one cycle. Allow warm-up before judging accuracy. Insulation resistance from each terminal to the ground terminal is 20 megohm or more at 500 VDC, and the dielectric limits are 2300 VAC for the supply, 1600 VAC for contact outputs and 1500 VAC for measuring inputs, each for one minute. For thermocouples use proper compensating cable, and for three-wire RTDs keep all three conductors at equal resistance. Set the clock first, since its stated accuracy is 10 ppm, then define ranges, scaling, alarms and display groups, and test the touch panel lock password.
Maintenance and spare planning
Routine care of a DX1012T-3-4-2 is light. Copy the CF card files on a fixed schedule, check the free space (the unit can overwrite the oldest file when space runs out, if that function is switched on), and wipe the screen with a soft cloth only; the datasheet warns against pushing or rubbing the touch surface with sharp objects. Replace the lithium backup battery near the ten-year mark, and keep a saved setup file on the card so a replacement DX1012T-3-4-2 can be configured in minutes. Because the exact suffix and option codes matter, record the complete model string from the nameplate before ordering any substitute.
Frequently asked points about DX1012T-3-4-2
Buyers of the DX1012T-3-4-2 most often ask about the meaning of the suffix, the real number of channels and speed, the input list, the option conflicts and the cut-out size; the FAQ below answers these with the datasheet values. Where a value is not listed in the Yokogawa document, we do not guess it.
Documents and quotation
The Yokogawa datasheet GS 04L45B01-01EN is attached to this page for download. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To request availability and a quotation, send an RFQ that quotes DX1012T-3-4-2 together with the option codes you need (for example /A2, /C3, /M1 or /USB1), the power cord code and the quantity.
Datasheets & Documents
- Datasheet Yokogawa DX1012T-3-4-2 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa DX1012T-3-4-2 12-Channel Touch Daqstation
Answers from our engineering team on installation, compatibility and integration.
01What does the suffix 3-4-2 in DX1012T-3-4-2 mean?
Per the Yokogawa model code table, -3 is the 400 MB internal memory, -4 is an external CF card supplied with media, and -2 is the English/German/French display language with degF and summer/winter time.
02How many channels does the DX1012T-3-4-2 measure and how fast?
It is the twelve-channel member of the DX1000T range. Its shortest measurement interval is 1 s, with a 125 ms fast sampling mode in which the A/D integration time is fixed to 1.67 ms.
03Which input signals can the DX1012T-3-4-2 accept?
DC voltage from 20 mV to 50 V, a 1-5 V range, thermocouples R, S, B, K, E, J, T, N, W, L, U and WRe, Pt100 and JPt100 RTDs, contact or TTL digital input, and DC current through an external shunt resistor.
04Can the DX1012T-3-4-2 be ordered with 3-leg isolated RTD inputs or batch functions?
Yes. The datasheet restricts the /N2 three-leg isolated RTD option and the /BT2 multi-batch option to the DX1006T and DX1012T, so this twelve-channel unit can carry both.
05What panel cut-out conditions apply to the DX1012T-3-4-2?
It is flush panel mounted, panel thickness 2 to 26 mm, body 144 x 144 mm with a depth of 224.1 mm (228.5 mm with the /H2 or /PM1 option), weight about 2.9 kg without options.


















Reviews
There are no reviews yet.