- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AMETEK
AMETEK 5100HD TDLAS Gas Analyzer for Moisture in Natural Gas
Description
Overview
The AMETEK 5100HD is a fixed, extractive gas analyzer from AMETEK Process Instruments that uses tunable diode laser absorption spectroscopy (TDLAS) to measure water vapour in natural gas. Built for hot and wet sample analysis, it serves pipelines and transmission networks, gas processing plants, dehydration units and custody transfer points, where moisture lowers the energy value of the gas, encourages hydrate formation and drives internal corrosion of pipes and equipment. Because the measurement is optical, nothing in the gas path touches a sensing element, so the analyzer avoids the gradual contamination and slow upset response that can affect contact-type moisture sensors.
Natural gas producers, midstream operators and processing plants in Oman and the GCC must prove water content against pipeline and sales specifications every hour of the day. Seven Star LLC supplies the AMETEK 5100HD for these duties, with engineering support in Muscat for application review, sample system questions and spare parts.
Measurement Principle
In the AMETEK 5100HD, a near-infrared diode laser is tuned across a single absorption line of water. The light passes through a sample cell filled with process gas, and the amount absorbed at that wavelength is proportional to the concentration of water molecules in the beam. The analyzer uses a fully digital implementation of wavelength modulation spectroscopy (WMS), which improves sensitivity and suppresses noise compared with simple direct absorption, giving a photometric response of less than two seconds.
A key part of the design is a sealed reference cell used to line-lock the laser on the chosen absorption line. Any small shift in the observed spectrum is fed back to adjust the laser, giving a real-time confirmation that it remains locked on the correct wavelength. For natural gas service the AMETEK 5100HD needs no sample conditioning other than particulate filtering and keeping the sample above its condensation point at the integrated oven temperature of up to 150 °C.
Engineering Design of the AMETEK 5100HD
The AMETEK 5100HD combines electronics, optics and a fully integrated, heated sample handling system in a stainless steel IP65 and Type 4X enclosure designed for outdoor installation in ambient temperatures from −20 to 50 °C. In its typical NEC/CEC Class I Division 2 or ATEX/IECEx Zone 2 configuration the cabinet measures about 880 × 674 × 302 mm and weighs around 60 kg, and versions certified to multiple ATEX, IECEx, CSA, NEC and Inmetro standards are available, including purged Zone 1 builds. It accepts 120 or 240 VAC or 24 VDC supply, drawing 25 to 45 W without heater and roughly 425 to 445 W with the oven heater active.
The AMETEK 5100HD has a local keypad and display, and communicates over Fast Ethernet with Modbus TCP/IP, an isolated RS485 port supporting Modbus RTU, up to two isolated 4–20 mA outputs and four dry relay contacts. Sample flow is 1 to 2 L/min depending on the application, at a cell pressure of 70 to 170 kPa absolute, so a simple pressure-reduced fast loop is usually sufficient.
Key Features
The features below explain why gas operators choose the AMETEK 5100HD for continuous moisture measurement.
- Non-contact laser measurement keeps maintenance low and resists contamination from glycol, hydrocarbons and particulates.
- Sealed reference cell line-lock verifies in real time that the laser is on the correct absorption line.
- Digital wavelength modulation spectroscopy gives a photometric response under two seconds for fast upset detection.
- A minimum range of 0 to 20 ppmv is standard, with other ppm and percent ranges available.
- Typical accuracy is ±2% of reading or ±4 ppm, whichever is greater.
- An integrated heated oven up to 150 °C keeps hot, wet samples above their dew point without separate conditioning.
- Modbus TCP/IP, Modbus RTU, 4–20 mA and relay outputs connect easily to DCS, SCADA and metering computers.
- Type 4X / IP65 construction and multiple hazardous-area certifications suit outdoor skid and shelter installations.
Industrial Applications
Across Oman’s gas value chain, the AMETEK 5100HD is suited to the outlet of glycol and molecular sieve dehydration units, to the inlet and outlet of gas processing trains and to custody transfer stations on the national gas network, where buyers and sellers rely on agreed water content limits. Its fast optical response lets operators spot dehydration upsets, such as glycol carry-over or saturated sieve beds, before wet gas travels downstream to compressors, meters and customers. Since the same 5100HD platform is offered for CO2, H2S, O2 and methane in other data sheets, plants can standardise spares and training across several measurement points.
In the wider GCC, gas processing complexes, LNG feed gas systems, refineries and petrochemical plants use the AMETEK 5100HD on feed stock and process streams where conventional sensors suffer from fouling. Seven Star LLC supplies the analyzer to operators and EPC contractors in Oman, the UAE, Saudi Arabia, Qatar, Kuwait and Bahrain, with engineering support in Muscat throughout the project.
Technical Specifications
The AMETEK 5100HD values below are taken from the manufacturer’s data sheet for moisture in natural gas (F-0432).
| Parameter | Specification |
|---|---|
| Model | AMETEK 5100HD (moisture in natural gas) |
| Technology | Tunable diode laser absorption spectroscopy, digital WMS, extractive |
| Measured component | H2O in natural gas |
| Minimum range | 0 to 20 ppmv (other ppm and % ranges available) |
| Accuracy | ±2% of reading or ±4 ppm, whichever is greater (typical) |
| Speed of response | < 2 s photometric; system response depends on sample flow |
| Laser verification | Sealed reference cell line-lock |
| Sample conditioning | Particulate filtering; integrated oven up to 150 °C |
| Sample flow | 1–2 L/min (2.1–4.2 SCFH), application dependent |
| Sample cell pressure | 70 to 170 kPa absolute (10 to 25 psia) |
| Ambient temperature | −20 to 50 °C; 0–90% RH non-condensing |
| Electrical | 120/240 VAC, 47–63 Hz, or 24 VDC |
| Power | 25–45 W without heater; 425–445 W with heater (typical) |
| Outputs | Keypad and display; Fast Ethernet, Modbus TCP/IP; RS485 Modbus RTU; up to 2 isolated 4–20 mA; 4 dry relays |
| Dimensions (W × H × D) | 880 × 674 × 302 mm (typical Div 2 / Zone 2) |
| Weight | Approx. 60 kg (typical Div 2 / Zone 2) |
| Enclosure | IP65 and Type 4X |
| Approvals | ATEX, IECEx, CSA, NEC and Inmetro hazardous-area standards (consult for details) |
Related AMETEK Analyzers
For portable checks and sulfur plant duties, see the AMETEK 5100P transportable TDLAS analyzer, AMETEK 900 tail gas air demand analyzer and AMETEK 930 H2S in sulfur pit analyzer.
How to Order
To order the AMETEK 5100HD, send Seven Star LLC a formal RFQ with your gas composition, moisture range, sample pressure and temperature, and hazardous-area classification. Our instrumentation team will confirm the right configuration, current availability and delivery to sites across Oman and the GCC. The product datasheet can be downloaded from this page, and our engineers in Muscat are ready to help with sample system layout and control system integration.
See also: AMETEK Land SPOT+ Series Smart Industrial Pyrometers.
Datasheets & Documents
- Datasheet AMETEK 5100HD Moisture in Natural Gas Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 5100HD TDLAS Gas Analyzer for Moisture in
Answers from our engineering team on installation, compatibility and integration.
01Why use the AMETEK 5100HD instead of a contact moisture sensor?
The AMETEK 5100HD measures water optically with a tunable diode laser, so no sensing element touches the gas. This avoids sensor degradation from repeated exposure to contaminants and the delayed response to process upsets that can affect contact-type sensors, keeping maintenance low.
02How does the AMETEK 5100HD confirm its laser is measuring correctly?
It uses a sealed reference cell to line-lock the laser on the selected water absorption line. Any minor shift in the observed spectrum is fed back to adjust the laser, giving real-time confirmation that the analyzer is locked on the correct wavelength.
03What sample conditioning does the AMETEK 5100HD need for natural gas?
For natural gas service no conditioning is required other than particulate filtering and ensuring the sample does not condense at the integrated oven temperature of up to 150 C. Sample flow is 1 to 2 L/min at a cell pressure of 70 to 170 kPa absolute.
04What outputs does the AMETEK 5100HD offer?
The analyzer provides a keypad and display, Fast Ethernet with Modbus TCP/IP, an isolated RS485 port with Modbus RTU, up to two isolated 4-20 mA outputs and four dry relay contacts. This makes connection to DCS, SCADA and flow computers straightforward.
05Can Seven Star LLC supply the AMETEK 5100HD in Oman and the GCC?
Yes. Seven Star LLC supplies the AMETEK 5100HD to gas producers, processing plants and EPC contractors across Oman and the GCC. As a trusted supplier we provide engineering support in Muscat for application review and spares.


















Reviews
There are no reviews yet.