Endress+Hauser t-mass 65F Thermal Mass Flowmeter

Description

Overview

The Endress+Hauser t-mass 65F is an inline thermal mass flowmeter designed for the direct mass flow measurement of industrial gases and compressed air. With a typical turndown of 100:1, it accurately captures both normal operational flow rates and low-flow leakage detection, making it a valuable tool for compressed air energy audits and gas distribution monitoring.

Working closely with plant engineers in the region, Seven Star LLC proudly supplies the Endress+Hauser t-mass 65F to industrial facilities and utilities across the Sultanate of Oman and the wider GCC, backed by genuine factory calibration, full documentation, and local technical support.

Measurement Principle

The Endress+Hauser t-mass 65F operates on the thermal dispersion principle. Two temperature sensors are exposed to the gas stream: one heated slightly above process temperature and one measuring the reference gas temperature. As gas flows past the heated sensor, it carries heat away at a rate proportional to mass flow, and the power required to maintain the temperature differential is measured and converted directly into mass flow rate.

Because the measurement is a direct mass reading, no separate pressure or temperature compensation is required as with volumetric flow technologies, which simplifies installation and improves long-term accuracy. The integrated gas engine allows the device to be configured for 20 freely selectable gases, giving plant engineers flexibility to redeploy the same instrument across different gas services.

Engineering Design of the Endress+Hauser t-mass 65F

The sensor is available in pipe diameters from 0.5 inch to 4 inch (12.7 mm to 102 mm) with flanged process connections, rated for operating pressures up to 580 psi and medium temperatures from –40°C to +130°C. The compact transmitter operates in ambient temperatures from –20°C to +60°C, with a digital front panel display for local readouts and configuration.

Outputs include current, frequency, and switch signals alongside network/fieldbus connectivity for integration into plant monitoring systems, allowing the t-mass 65F to feed both local indication and centralized energy management or SCADA platforms directly.

Key Features

The Endress+Hauser t-mass 65F is engineered for direct, reliable gas mass flow measurement, and the Endress+Hauser t-mass 65F is widely used for compressed air efficiency programs across industrial plants:

  • Measures mass flow directly with no separate pressure or temperature compensation required.
  • Delivers a typical turndown ratio of 100:1, capturing both operational flow and low-flow leakage.
  • Achieves measurement accuracy of ±1.5% o.r. across 10 to 100% of full scale.
  • Includes an integrated gas engine configurable for 20 freely selectable gases.
  • Covers pipe diameters from 0.5 inch to 4 inch (12.7 mm to 102 mm).
  • Handles medium temperatures from –40°C to +130°C and operating pressures up to 580 psi.
  • Provides current, frequency, and switch outputs with network/fieldbus connectivity.
  • Features a digital front panel display for straightforward local configuration and diagnostics.

Industrial Applications

The Endress+Hauser t-mass 65F is specified for compressed air system audits, industrial gas distribution monitoring, natural gas measurement, and energy management programs where leak detection and accurate mass-based accounting drive real cost savings. It also suits process plants tracking nitrogen, oxygen, and other utility gas consumption across multiple points.

With fast quotation turnaround and technical support, Seven Star LLC supplies the t-mass 65F to industrial facilities throughout Oman and the GCC, including projects in the Sohar and Salalah economic zones, manufacturing plants, and utility distribution networks, with lead time confirmed at quotation.

Technical Specifications

Key technical parameters for the Endress+Hauser t-mass 65F are summarized below.

Parameter Specification
Model Endress+Hauser Proline t-mass 65F
Measuring Principle Thermal dispersion (direct mass flow)
Pipe Diameter 0.5″ to 4″ (12.7 to 102 mm)
Measurement Accuracy ±1.5% o.r. (10–100% o.f.s.)
Turndown Ratio Typically 100:1
Medium Temperature –40°C to +130°C
Operating Pressure Up to 580 psi
Gas Configuration Integrated gas engine, 20 selectable gases

Why Choose Seven Star LLC for Endress+Hauser Thermal Mass Flowmeters

Getting real value from a thermal mass meter on a compressed air or gas efficiency program depends on configuring the integrated gas engine for your actual gas composition and setting pipe size correctly for the flow range you need to capture, from normal operation down into leak-detection territory. Seven Star LLC helps your facilities and energy teams configure the t-mass 65F for the correct gas service and pipe diameter before shipment, drawing on our trusted Endress+Hauser suppliership across Oman and the wider GCC. We also support industrial plants across Muscat, Sohar, and Salalah running compressed air audit and energy management programs by planning multiple metering points together, so gas efficiency data feeds cleanly into a single plant-wide monitoring system, and we help facilities plan periodic recalibration schedules to keep leak-detection thresholds accurate as compressed air demand patterns shift over time.

Request a Quote for Endress+Hauser t-mass 65F Thermal Mass Flowmeter

For compressed air and gas distribution systems standardizing on the Endress+Hauser t-mass 65F, Seven Star LLC is ready to support your project with a formal RFQ, technical datasheet, and delivery timeline. Our instrumentation engineers provide technical support with selection across Oman and the GCC, with lead time confirmed at quotation. With engineering support in Muscat, contact our instrumentation division today to configure the right t-mass 65F variant for your gas service, complete with manufacturer documentation.

Related Products

Datasheets & Documents
  • PDF Datasheet Endress+Hauser t-mass 65F Thermal Mass Flowmeter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.

Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.

Endress+Hauser company profile

Origin Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser
Headquarters Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland
Ownership Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned
Size About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company)
Product families Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis

Milestones

  • 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
  • 1957: The Endress+Hauser name comes into use.
  • 1975: The Endress family becomes sole shareholder.
  • 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.

Endress+Hauser product lines

Line Measuring principle Typical use
Promass F 300, Promass 80F, 83F/84F Coriolis mass flow Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing
Promag P 300, P 500, H 300, W 400, W 10, 50P Electromagnetic flow Water, wastewater, slurries and other conductive liquids
Prowirl F 200, 72F Vortex flow Steam, gas and low-viscosity liquids
Prosonic Flow 92F, t-mass 65F Ultrasonic and thermal mass flow Water lines; compressed air and industrial gases
Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 Free-space radar level, 80 GHz and 26 GHz Tanks, process vessels, silos and open water channels
Levelflex FMP51, FMP50, FMP54, FMP55 Guided wave radar level Level and interface in vessels, separators and bypass chambers
Liquiphant FTL51, Prosonic S FMU90 Vibronic point level; ultrasonic level High and low level alarms, pump protection, open channel flow
Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 Pressure and differential pressure Process pressure, hydrostatic level and DP flow
iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 Temperature transmitters and thermometers RTD and thermocouple points with thermowells
Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents Liquid analysis pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process

Where Endress+Hauser instruments are used

In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.

Ordering Endress+Hauser instruments: what we need

The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.

Facts checked against Endress+Hauser company history and product information, October 2026.

FAQ

Questions about the Endress+Hauser t-mass 65F Thermal Mass Flowmeter

Answers from our engineering team on installation, compatibility and integration.

01What makes the Endress+Hauser t-mass 65F useful for compressed air leak detection?
Its typical 100:1 turndown ratio allows the t-mass 65F to accurately measure both normal operational flow and the very low flow rates typical of system leaks, making it well suited to compressed air efficiency audits.
02Does the t-mass 65F require pressure or temperature compensation?
No. Because the thermal dispersion principle measures mass flow directly, the t-mass 65F does not require separate pressure or temperature compensation, which simplifies installation compared to volumetric flow technologies.
03Can the t-mass 65F be used for different gas types?
Yes. The integrated gas engine can be configured for 20 freely selectable gases, allowing the same instrument to be redeployed across compressed air, nitrogen, natural gas, and other utility gas services.
04What pipe sizes does the t-mass 65F support?
The t-mass 65F covers pipe diameters from 0.5 inch to 4 inch (12.7 mm to 102 mm), with flanged process connections rated to operating pressures up to 580 psi.
05Is Seven Star LLC an experienced supply partner for Endress+Hauser products?
Yes. Seven Star LLC supplies Endress+Hauser (E & H) products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.