Brand:

ifm SD6020 Compressed Air Meter, R 1/2 DN15, IO-Link, IP 67

Description

ifm SD6020 overview

The ifm SD6020 is a compressed air meter for DN15 pipework with an R 1/2 external thread. It has two switching outputs, a scalable analogue output, a pulse output for consumed quantity and IO-Link, and its housing is rated IP 65 and IP 67. Its measuring range starts lower than the SD6000, at 4 l/min. Ordering description: SDR12DGXFRKG/US-100.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list this device so that maintenance, procurement and project teams can quote the exact part number against the manufacturer data.

Key features of the SD6020

  • Measuring range 4 to 1250 l/min, or 0.3 to 99.8 m/s, or 0.25 to 75 cubic metres per hour.
  • Medium temperature minus 10 to plus 60 degrees Celsius; pressure rating 16 bar.
  • Temperature monitoring accuracy plus or minus 0.5 K as listed in the datasheet.
  • Outputs configurable between switching, analogue, pulse and IO-Link.
  • Operating voltage 18 to 30 V DC to SELV and PELV.

SD6020 technical specifications

Parameter Value from the manufacturer datasheet
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range 4…1250 l/min 0.3…99.8 m/s 0.25…75 m³/h
Process connection threaded connection R 1/2 external thread DN15
Application for industrial applications
Media compressed air
Medium temperature [°C] -10…60
Min. burst pressure 64 bar 6.4 MPa
Pressure rating 16 bar 1.6 MPa
Operating voltage [V] 18…30 DC; (to SELV/PELV)
Current consumption [mA] less than 80
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs counter reset
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Overload protection yes
Display range 0…1500 l/min 0…119.8 m/s 0…90 m³/h
Resolution 1 l/min 0.1 m/s 0.05 m³/h
Set point SP 11…1250 l/min 0.9…99.8 m/s 0.65…74.97 m³/h
Reset point rP 5…1243 l/min 0.4…99.3 m/s 0.28…74.6 m³/h
Analogue start point ASP 0…1000 l/min 0…79.8 m/s 0…60 m³/h
Analogue end point AEP 250…1250 l/min 20…99.8 m/s 15…75 m³/h
Low flow cut-off LFC 1…13 l/min 0.1…1.1 m/s 0.09…0.8 m³/h
In steps of 1 l/min 0.1 m/s 0.01 m³/h
Pulse value 0.001…10000000 m³ 0.05…353146667.2 scf
Pulse length [s] 0.002…2
Analogue start point -10…46 °C 14…114.8 °F
Analogue end point 4…60 °C 39.2…140 °F
Temperature coefficient [1/K] ± 0,07 % MW
Accuracy (in the measuring ± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344)
range) (DIN8573-1:2010); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths
Repeatability ± 1,5 % MW
Accuracy [K] ± 0,5; (medium flow in the limit area of the flow measurement range)
Response time [s] less than 0.1; (dAP = 0, T09)
Damping process value dAP [s] 0…5
Dynamic response T05 / T09 [s] T09 = 0,5
Parameter setting options hysteresis / window; normally open / normally closed; current/pulse
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)

All values above are taken from the manufacturer datasheet for the SD6020. Ranges are written with three dots, for example 18…30 means 18 to 30. Where a limit depends on the medium or the installation, the datasheet condition applies.

Typical applications in oil and gas, utilities, water and manufacturing

Compressed air is a costly utility in oil and gas plants, power stations and manufacturing sites across Oman and the GCC. A compressed air meter at each branch lets maintenance teams allocate consumption, spot leaks by comparing night and day flow, and verify compressor performance. Instrument air headers, plant air rings and workshop air networks are typical measuring points.

In Oman and the wider GCC, compressed air metering devices like the SD6020 are found in consumption allocation, leak surveys and compressor performance checks. Hot ambient conditions, dust and long cable runs make a sensor with clear local indication and stable outputs valuable, because it shortens fault finding for the shift technician. Check the ambient and medium temperature limits in the table above against the actual site conditions before selecting the device.

Selection and compatibility notes for the SD6020

The SD6020 differs from the SD6000 mainly in its lower start of range and IP 67 rating. For larger lines move to the DN25 SD8000 or DN50 SD2000 housings described in the same family. Make sure the compressed air meets the quality class assumed by the accuracy statement, since the datasheet ties the stated accuracy to air quality class 344.

When you match this device to an existing loop, compare the supply voltage, output type, connector and process connection with the installed device, and confirm that the control system input accepts the signal. Because the part number identifies one exact version in the family, a similar-looking sibling can differ in output polarity, range or thread, and it is better to quote the exact designation than a family name.

Installation and commissioning

Mount the meter in a straight pipe run with the arrow on the housing in the flow direction and the sensing element in the centre of the pipe. Depressurise the line before fitting, use the specified thread sealing method, and keep the inlet and outlet runs given in the operating instructions. Set the scaling, pulse value and switching limits during commissioning, and reset the quantity counter only after recording the starting reading.

Before power-up, check the wiring against the connection diagram in the datasheet, and after power-up allow any start-up delay listed in the table to elapse before judging the output. Document the settings made on site together with the serial number so that a replacement can be configured identically.

Maintenance and service

Keep the compressed air dry and filtered to the quality class assumed in the accuracy statement, because oil or water carry-over can foul the sensing element. Read the totaliser periodically and compare it against compressor load hours, which is the quickest check that the meter and the plant still agree.

Related products and ordering notes

Related ifm devices already listed in the Seven Star catalogue can be found through the brand page. When you request this device, please state the quantity, the required delivery location and whether a datasheet copy is needed. If the application is critical, tell us the process medium, pressure and temperature so the engineer can check the data before the quotation is prepared.

Frequently asked questions

  • What is the ifm SD6020? The ifm SD6020 is a compressed air flow meter with a DN15 R 1/2 thread and IP 67 housing. The ifm SD6020 is a compressed air meter for DN15 pipework with an R 1/2 external thread.
  • What supply and protection rating does the SD6020 have? According to the manufacturer datasheet the SD6020 operates from 18…30 DC; (to SELV/PELV) and has protection III.
  • Is the SD6020 still available from the manufacturer? The manufacturer datasheet does not carry a phase-out or archive notice, but availability changes over time, so ask us to confirm stock and lead time when you send the RFQ.
  • Does Seven Star LLC supply the SD6020 in Oman? Yes, Seven Star LLC quotes the SD6020 for projects and maintenance in Oman and the GCC. Send the part number SD6020 and the quantity and we will respond with availability.
  • How do I get a quotation for the SD6020? Use the RFQ form on this page with the part number SD6020, the quantity and your delivery location. We will reply with a quotation after checking availability.

Documents and quotation

The manufacturer datasheet is attached to this page where the file is available, and it is the reference for every value shown here. To order, send the RFQ with part number SD6020 and the quantity required, together with the delivery location and any application details. Our team will confirm availability and respond with a quotation.

Datasheets & Documents
  • PDF Datasheet ifm SD6020 Compressed Air Meter, R 1/2 DN15, IO-Link, IP 67 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm SD6020 Compressed Air Meter, R 1/2 DN15,

Answers from our engineering team on installation, compatibility and integration.

01What is the ifm SD6020?
The ifm SD6020 is a compressed air flow meter with a DN15 R 1/2 thread and IP 67 housing. The ifm SD6020 is a compressed air meter for DN15 pipework with an R 1/2 external thread.
02What supply and protection rating does the SD6020 have?
According to the manufacturer datasheet the SD6020 operates from 18...30 DC; (to SELV/PELV) and has protection III.
03Is the SD6020 still available from the manufacturer?
The manufacturer datasheet does not carry a phase-out or archive notice, but availability changes over time, so ask us to confirm stock and lead time when you send the RFQ.
04Does Seven Star LLC supply the SD6020 in Oman?
Yes, Seven Star LLC quotes the SD6020 for projects and maintenance in Oman and the GCC. Send the part number SD6020 and the quantity and we will respond with availability.
05How do I get a quotation for the SD6020?
Use the RFQ form on this page with the part number SD6020, the quantity and your delivery location. We will reply with a quotation after checking availability.