Brand:

ifm SD2000 Compressed Air Meter, R 2 DN50, IO-Link

Description

ifm SD2000 overview

The ifm SD2000 is a compressed air meter for DN50 lines with an R 2 external thread, listed by the manufacturer as a phase-out article with the SD2500 named as the alternative. It covers up to 700 cubic metres per hour and provides flow, consumption and temperature data through switching, analogue, pulse and IO-Link outputs. Ordering description: SDR21DGXFPKG/US-100.

Status note: in the manufacturer datasheet the SD2000 is listed by the manufacturer as a phase-out article, with the SD2500 named as the alternative article. The datasheet adds that when an alternative article is chosen, its technical data may differ, so engineers should compare the new data sheet before replacing an installed unit. This page describes the SD2000 as documented in that datasheet; ask us about current availability when you send the RFQ.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list this device so that maintenance, procurement and project teams can quote the exact part number against the manufacturer data.

Key features of the SD2000

  • Measuring range 0.3 to 95.2 m/s, 3 to 700 cubic metres per hour, or 0.04 to 11.66 cubic metres per minute.
  • Pressure rating 16 bar, medium temperature 0 to 60 degrees Celsius.
  • Operating voltage 18 to 30 V DC to SELV and PELV, IP 65.
  • Accuracy for temperature plus or minus 2 K in the limit area.
  • IO-Link revision 1.1 interface.

SD2000 technical specifications

Parameter Value from the manufacturer datasheet
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range 0.3…95.2 m/s 3…700 m³/h 0.04…11.66 m³/min
Process connection threaded connection R 2 external thread DN50
Application for industrial applications
Media compressed air
Note on media air quality ISO 8573-1
Medium temperature [°C] 0…60
Pressure rating 16 bar 1.6 MPa
Operating voltage [V] 18…30 DC; (to SELV/PELV)
Current consumption [mA] less than 110
Min. insulation resistance [MΩ] 100; (500 V DC)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Number of analogue outputs 1
Analogue current output [mA] 4…20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Overload protection yes
Display range 0…114.2 m/s 0…840 m³/h 0…13.99 m³/min
Set point SP 0.7…95.2 m/s 5…700 m³/h 0.09…11.66 m³/min
Reset point rP 0.3…94.8 m/s 2…697 m³/h 0.04…11.61 m³/min
Analogue start point ASP 0…71.4 m/s 0…525 m³/h 0…8.75 m³/min
Analogue end point AEP 23.8…95.2 m/s 175…700 m³/h 2.91…11.66 m³/min
In steps of 0.1 m/s 1 m³/h 0.01 m³/min
Pulse value 0.010…4000000 m³
Pulse length [s] 0,021…2
Measuring range [°C] 0…60
Display range [°C] -12…72
Accuracy (in the measuring ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class)
range) 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)
Accuracy [K] ± 2; (medium flow in the limit area of the flow measurement range)
Response time [s] 0.1; (dAP = 0)
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring;
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2

All values above are taken from the manufacturer datasheet for the SD2000. Ranges are written with three dots, for example 18…30 means 18 to 30. Where a limit depends on the medium or the installation, the datasheet condition applies.

Typical applications in oil and gas, utilities, water and manufacturing

Compressed air is a costly utility in oil and gas plants, power stations and manufacturing sites across Oman and the GCC. A compressed air meter at each branch lets maintenance teams allocate consumption, spot leaks by comparing night and day flow, and verify compressor performance. Instrument air headers, plant air rings and workshop air networks are typical measuring points.

In Oman and the wider GCC, compressed air metering devices like the SD2000 are found in consumption allocation, leak surveys and compressor performance checks. Hot ambient conditions, dust and long cable runs make a sensor with clear local indication and stable outputs valuable, because it shortens fault finding for the shift technician. Check the ambient and medium temperature limits in the table above against the actual site conditions before selecting the device.

Selection and compatibility notes for the SD2000

For header-size meters on compressor discharge lines, the DN50 size is common. Check the thread (R 2 external) against the existing spool piece. The SD2500 is the manufacturer’s alternative, but data may differ, so verify before replacing.

When you match this device to an existing loop, compare the supply voltage, output type, connector and process connection with the installed device, and confirm that the control system input accepts the signal. Because the part number identifies one exact version in the family, a similar-looking sibling can differ in output polarity, range or thread, and it is better to quote the exact designation than a family name.

Installation and commissioning

Mount the meter in a straight pipe run with the arrow on the housing in the flow direction and the sensing element in the centre of the pipe. Depressurise the line before fitting, use the specified thread sealing method, and keep the inlet and outlet runs given in the operating instructions. Set the scaling, pulse value and switching limits during commissioning, and reset the quantity counter only after recording the starting reading.

Before power-up, check the wiring against the connection diagram in the datasheet, and after power-up allow any start-up delay listed in the table to elapse before judging the output. Document the settings made on site together with the serial number so that a replacement can be configured identically.

Maintenance and service

Keep the compressed air dry and filtered to the quality class assumed in the accuracy statement, because oil or water carry-over can foul the sensing element. Read the totaliser periodically and compare it against compressor load hours, which is the quickest check that the meter and the plant still agree.

Related products and ordering notes

Related ifm devices already listed in the Seven Star catalogue can be found through the brand page. When you request this device, please state the quantity, the required delivery location and whether a datasheet copy is needed. If the application is critical, tell us the process medium, pressure and temperature so the engineer can check the data before the quotation is prepared.

Frequently asked questions

  • What is the ifm SD2000? The ifm SD2000 is a compressed air flow meter with a DN50 R 2 thread, listed as a phase-out article. The ifm SD2000 is a compressed air meter for DN50 lines with an R 2 external thread, listed by the manufacturer as a phase-out article with the SD2500 named as the alternative.
  • What supply and protection rating does the SD2000 have? According to the manufacturer datasheet the SD2000 operates from 18…30 DC; (to SELV/PELV) and has protection III.
  • Is the SD2000 still available from the manufacturer? The datasheet marks the SD2000 as a phase-out article and names the SD2500 as the alternative. Compare the data sheets before replacing it.
  • Does Seven Star LLC supply the SD2000 in Oman? Yes, Seven Star LLC quotes the SD2000 for projects and maintenance in Oman and the GCC. Send the part number SD2000 and the quantity and we will respond with availability.
  • How do I get a quotation for the SD2000? Use the RFQ form on this page with the part number SD2000, the quantity and your delivery location. We will reply with a quotation after checking availability.

Documents and quotation

The manufacturer datasheet is attached to this page where the file is available, and it is the reference for every value shown here. To order, send the RFQ with part number SD2000 and the quantity required, together with the delivery location and any application details. Our team will confirm availability and respond with a quotation.

Datasheets & Documents
  • PDF Datasheet ifm SD2000 Compressed Air Meter, R 2 DN50, IO-Link Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ifm is a German family-owned maker of sensors and automation products, founded in Essen in October 1969 by Robert Buck and Gerd Marhofer. Its first products were inductive proximity sensors sold under the efector name. ifm is still headquartered in Essen, and the founders' sons, Martin Buck and Michael Marhofer, have led it since 2001.

Seven Star LLC lists ifm position, distance and pressure sensors and supplies them by exact article number to plants and machine builders in Oman and the wider Gulf region.

ifm company profile

Founded 1969, Essen, Germany
Founders Robert Buck and Gerd Marhofer
Headquarters Essen, Germany
Ownership Family-owned
Product families Inductive and capacitive proximity sensors, PN pressure sensors, O1D laser distance sensors, flow and level sensors, IO-Link masters

Milestones

  • 1969: ifm is founded in Essen.
  • 2001: The founders' sons take over management.

ifm sensors listed on this page

ifm identifies every device with a short article number, and that number is what we order against. Three are listed here:

  • O1D100: laser distance sensor for position and distance measurement
  • PN7093: pressure sensor with local display
  • NG5021: inductive proximity sensor with NAMUR output

Other ifm inductive sensors, pressure sensors and connection cables can be quoted on request when you send the article number.

ifm products we list

Family Examples
Inductive Proximity Sensors NG5021 Inductive NAMUR Proximity Sensor
Laser Distance, LiDAR & Radar Sensors O1D100 Laser Distance Sensor
Pressure Instrumentation PN7093 Pressure Sensor with Display

Ordering ifm sensors: what we need

Send the six-character article number printed on the housing (two letters and four digits, or similar). If the label is worn, a photo plus the thread size, sensing range, output type and connector style is enough for us to check the part against ifm documentation. For NAMUR sensors, tell us which isolating amplifier is in the loop. Buyers in the GCC who need a successor for a discontinued article can send the old number and we will check the replacement the manufacturer names.

Facts checked against ifm's own 50-year chronicle (ifm.com), October 2026.

FAQ

Questions about the ifm SD2000 Compressed Air Meter, R 2 DN50, IO-Link

Answers from our engineering team on installation, compatibility and integration.

01What is the ifm SD2000?
The ifm SD2000 is a compressed air flow meter with a DN50 R 2 thread, listed as a phase-out article. The ifm SD2000 is a compressed air meter for DN50 lines with an R 2 external thread, listed by the manufacturer as a phase-out article with the SD2500 named as the alternative.
02What supply and protection rating does the SD2000 have?
According to the manufacturer datasheet the SD2000 operates from 18...30 DC; (to SELV/PELV) and has protection III.
03Is the SD2000 still available from the manufacturer?
The datasheet marks the SD2000 as a phase-out article and names the SD2500 as the alternative. Compare the data sheets before replacing it.
04Does Seven Star LLC supply the SD2000 in Oman?
Yes, Seven Star LLC quotes the SD2000 for projects and maintenance in Oman and the GCC. Send the part number SD2000 and the quantity and we will respond with availability.
05How do I get a quotation for the SD2000?
Use the RFQ form on this page with the part number SD2000, the quantity and your delivery location. We will reply with a quotation after checking availability.