- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Siemens
Siemens Maxum II FPD Hydrogen Restrictor Stainless Steel 2021388-004
Description
Overview: Precision Fuel Gas Control for the FPD Flame
The Siemens Maxum II FPD Hydrogen Restrictor, part number 2021388-004, is a stainless steel tube assembly that precisely restricts and meters the hydrogen fuel gas supply feeding the Flame Photometric Detector (FPD) burner on the Siemens Maxum Edition II process gas chromatograph. The FPD combusts sample components in a hydrogen-rich flame to generate the characteristic sulfur-emission light the detector measures, and this restrictor’s calibration is what establishes the correct hydrogen flow rate for that flame – a rate that, when the FPD uses hydrogen as carrier gas rather than nitrogen, helium, or argon, is adjusted downward since additional flame-fuel hydrogen is then reduced.
As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the FPD hydrogen restrictor 2021388-004 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation.
Working Principle: Calibrated Fuel Gas Restriction
The restrictor works by presenting a precisely sized internal flow path to the hydrogen fuel line, creating a defined pressure drop that sets the hydrogen flow rate delivered to the FPD burner’s outer annular gap for a given upstream supply pressure. This hydrogen flow mixes with combustion air from the burner’s inner annular gap to sustain the flame in which sample sulfur compounds are combusted, and the ratio between hydrogen fuel and combustion air directly governs whether the flame ignites reliably and how sensitive the resulting photometric signal will be.
Because the FPD’s overall hydrogen requirement (approximately 100–130 mL/min for the FPD II, combining flame fuel and carrier gas contributions) depends on whether hydrogen or an inert gas is used as carrier, the restrictor’s fixed calibration is specified for a defined configuration, and substituting a restrictor from a different calibration point in the parts family can unbalance the flame chemistry even though the fitting may look identical.
Engineering Design of the Restrictor
The 2021388-004 restrictor is machined to the specific flow-calibration dimensions required for FPD hydrogen fuel service, distinct from both the FPD combustion air restrictor and the equivalent restrictors calibrated for the FID detector family. Stainless steel construction keeps the restrictor’s internal flow-path geometry dimensionally stable and corrosion-free over long service life, protecting the precision the flame chemistry depends on.
As with all components in the FPD gas supply path, Siemens specifies that gases and supply lines feeding this highly sensitive detector must be kept extremely clean and sulfur-free to maintain a strong signal-to-noise ratio, making correct restrictor selection and clean installation practice important during any FPD gas-path servicing.
Key Features
The FPD Hydrogen Restrictor 2021388-004 delivers the precise fuel gas calibration the FPD flame depends on. Key characteristics include:
- Stainless steel construction for corrosion resistance and dimensional stability over long service life.
- Precisely calibrated flow restriction specific to FPD hydrogen fuel requirements.
- Directly affects flame ignition reliability and photometric detection sensitivity when correctly installed.
- Distinct calibration from the corresponding FID hydrogen restrictor within the same parts family.
- Genuine Siemens Maxum II part number for correct fit and flame stoichiometry.
Industrial Applications
The FPD hydrogen restrictor is a required component wherever a Maxum Edition II analyzer is configured with a Flame Photometric Detector for sulfur-selective analysis, including natural gas sulfur specification testing and refinery sulfur recovery unit monitoring. Because it directly governs flame fuel supply, it is checked and, where necessary, replaced during FPD troubleshooting when ignition reliability or sensitivity issues are reported.
Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of this and other Maxum Edition II FPD gas-path hardware, helping analyzer houses maintain reliable sulfur-selective detection.
Technical Specifications
The table below summarizes the core specifications of the Siemens Maxum II FPD Hydrogen Restrictor as supplied by Seven Star LLC.
| Parameter | Specification |
|---|---|
| Model / Part Number | Hydrogen Restrictor, FPD, Stainless Steel, P/N 2021388-004 |
| Function | Calibrated hydrogen fuel gas flow restriction to the FPD burner |
| Material | Stainless steel |
| Compatible Detector | Flame Photometric Detector (FPD) |
| Target Platform | Siemens Maxum Edition II Process Gas Chromatograph |
| Typical Total Hydrogen Flow (FPD II) | Approx. 100–130 mL/min (flame fuel plus carrier, if hydrogen carrier used) |
| Hardware Condition | New, genuine Siemens part number |
Why Choose Seven Star LLC for FPD Fuel Gas Calibration Parts
Because the FPD’s hydrogen restrictor calibration depends on whether hydrogen or an inert gas is used as carrier, ordering the wrong restrictor from the broader Maxum II parts family – even one that looks identical to the correct one – can unbalance the flame chemistry and either prevent ignition or shift detector sensitivity. Seven Star LLC verifies the customer’s specific carrier gas configuration and detector setup before shipping this restrictor, rather than assuming a generic fitting will match. We also emphasize Siemens’ requirement that FPD gas supply lines stay extremely clean and sulfur-free, and help refinery and gas plant instrumentation teams across Oman keep correctly identified restrictor stock on hand for FPD troubleshooting, coordinating delivery across Muscat, Sohar, and the broader GCC.
Request a Quote for Siemens Maxum II FPD Hydrogen Restrictor Stainless Steel 2021388-004
Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and FPD gas-path hardware throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the FPD Hydrogen Restrictor 2021388-004 with your specific Maxum II configuration, contact our instrumentation sourcing team today.
Related Products
- Teledyne AP00465 Model PX2 LED UV Fluorescence Transmitter with PMT Detector
- APPLIED SRX-CT23 Oxygen Sensor
- LAR 501-08-000045 Gas Drying Tube for Carrier TOCUV1A0 – Long
- MSA GALAXY GX2 Automated Test System
- SMC AW20 Air Filter & Pressure Regulator
- Siemens Maxum II 2-Cell Filament Detector Repair Kit 2020379-701
Datasheets & Documents
- Instruction Manual Siemens Maxum II FPD Hydrogen Restrictor Stainless Steel 2021388-004 Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.
Siemens company profile
| Founded | 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees |
|---|---|
| Founders | Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890) |
| First product | The pointer telegraph designed by Werner von Siemens |
| Headquarters | Munich, Germany (Siemens AG) |
| Ownership | Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies |
| Businesses acquired that appear in our range | Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003 |
| Product families | SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors |
Milestones
- 1847: Siemens & Halske starts work in Berlin with 10 employees.
- 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
- 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
- 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
- 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
- 2020: Siemens Energy is spun off and listed separately.
Choosing Siemens automation products
A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.
Where Siemens products are used
In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.
Siemens products we list
| Family | Examples |
|---|---|
| SIMATIC controllers and I/O | S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2 |
| HMI and networking | KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM |
| Drives, motors and power distribution | SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB |
| Process instruments | SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200 |
| Maxum II analyser spares | FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater |
| APACS and QUADLOG spares | QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable |
| Building technology | VPI46 PICV, VPF44, QFM1660 sensor |
Ordering Siemens products: what we need
Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.
Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.
Facts checked against Siemens's published history timeline, October 2026.
FAQ
Questions about the Siemens Maxum II FPD Hydrogen Restrictor Stainless
Answers from our engineering team on installation, compatibility and integration.
01What does this restrictor control?
It precisely restricts and meters the hydrogen fuel gas supply feeding the FPD burner, establishing the correct hydrogen flow rate for the detector's combustion flame.
02How much hydrogen does the FPD typically require?
The FPD II typically requires approximately 100-130 mL/min of total hydrogen, combining flame fuel and carrier gas contributions if hydrogen is also used as carrier gas.
03Is this restrictor the same as the FID hydrogen restrictor?
No, although part of the same Maxum II restrictor family, the FPD hydrogen restrictor is calibrated differently from the corresponding FID restrictor, so correct part selection matters.
04Why is stainless steel used for this restrictor?
Stainless steel keeps the restrictor's internal flow-path geometry dimensionally stable and corrosion-free, preserving the precise hydrogen flow the flame chemistry depends on.
05Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II FPD Hydrogen Restrictor 2021388-004 to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.


















Reviews
There are no reviews yet.