- Automation & ControlView all 3,052 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Isolator & Barrier
- Controllers & Data Acquisition
- Safety Switches & Guard Locking
- Motor Soft Starters
- Encoders
- CCTV & Security
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa EJA130E-JMS5J-912NB High Static Pressure DP
Description
DP at high line pressure: EJA130E-JMS5J-912NB
Differential pressure transmitters tend to fail at the edges of their pressure rating, not in the middle. Yokogawa EJA130E-JMS5J-912NB is the EJA130E in its base M-capsule form, designed for differential measurement under very high static pressure: maximum working pressure is 32 MPa (4500 psi) with B7 bolting, against 16 MPa for the EJA115E low flow model. The M capsule spans 1 to 100 kPa, and the output is 4 to 20 mA with HART.
The code JMS5J-912NB means HART, M capsule, stainless wetted parts, no process connector (1/4 NPT female cover flange ports), B7 bolts, horizontal piping with the left side high pressure, aluminum housing, 1/2 NPT conduit entries, no indicator and a flat 304 SST bracket.
EJA130E-JMS5J-912NB decoded
| Code position | Meaning |
|---|---|
| -J | 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering) |
| M | Capsule: span 1 to 100 kPa |
| S | Wetted parts: F316 SST cover flange, ASTM CF-8M connector, Hastelloy C-276 diaphragm, Teflon-coated 316L SST gasket, 316 SST plug |
| 5 | Process connection: without process connector (1/4 NPT female on the cover flanges) |
| J | Bolts and nuts: B7 carbon steel (32 MPa MWP) |
| -9 | Installation: horizontal piping, left side high pressure |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| N | Integral indicator: none |
| B | Mounting bracket: 304 SST 2-inch pipe bracket, flat type (horizontal piping) |
M capsule numbers
Reference accuracy is plus or minus 0.055 percent of span for spans of 10 kPa or larger, with the datasheet formula of 0.005 plus 0.005 times URL over span for smaller spans. URL is 100 kPa. Ambient temperature effect is plus or minus (0.07 percent of span plus 0.02 percent of URL) per 28 degrees C. Static pressure effects per 6.9 MPa are plus or minus 0.1 percent of span on span and plus or minus 0.028 percent of URL on zero. Over-pressure effect with B7 bolts is plus or minus 0.03 percent of URL, and long-term stability is plus or minus 0.1 percent of URL over ten years. Response time is 150 ms.
Specifications of EJA130E-JMS5J-912NB
| Item | Value |
|---|---|
| Capsule M | 1 to 100 kPa span; range minus 100 to 100 kPa |
| Max working pressure | 32 MPa (4500 psi) with bolts J, G and C |
| Burst | 132 MPa (19100 psi) |
| Process connection | 1/4 NPT female on cover flanges (no connector) |
| Bolting | B7 carbon steel |
| Output | 4 to 20 mA, HART 5/7 |
| Process temperature | Minus 40 to 120 degrees C |
| Ambient | Minus 40 to 85 degrees C |
| Response time | 150 ms |
| Update period | Differential pressure 45 ms; static pressure 360 ms |
| Weight | 6.8 kg without indicator and bracket |
Where high static pressure appears
Orifice flow metering of high-pressure gas and steam, differential measurement across high-pressure separators and filters, water injection and gas lift lines are the typical uses. The unit can also report static pressure through the HART interface, so one device gives flow differential and line pressure for flow compensation.
Choosing the M capsule
The H capsule spans 5 to 500 kPa and the V capsule 0.14 to 14 MPa. The M capsule is the sensitive element for low differential pressures, such as orifice plates sized for 1 to 100 kPa at gas pipelines. If your calculated differential exceeds 100 kPa, select H or V rather than ranging the M capsule beyond its limit.
Installation of EJA130E-JMS5J-912NB
With no process connectors, impulse piping connects to 1/4 NPT female ports on the cover flanges. Use a 5-valve manifold for isolation and equalizing. The horizontal -9 installation has the high-pressure side on the left. Apply static pressure slowly; never open one side of the manifold at line pressure, since the capsule is rated for over-pressure effects only up to the MWP.
Check bolts and gaskets for leakage after pressure cycling and trim zero with both sides equalized.
Electrical data and options for EJA130E-JMS5J-912NB
Supply voltage is 10.5 to 42 V DC for general use, and HART communication requires at least 16.6 V DC at the terminals with 250 to 600 ohm of loop resistance. The output range is 3.6 to 21.6 mA, the default failure alarm is up-scale at 110 percent, and NAMUR NE43 limits are available through options C2 and C3. Under IEC 61508, the standard HART configuration is certified SIL 2 capable for single use and SIL 3 for dual use. Local parameter setting works through the external zero screw and push button when an indicator with range switch is fitted, which is not the case for EJA130E-JMS5J-912NB. Housing protection is IP66/IP67 and Type 4X, and PED 2014/68/EU sound engineering practice applies to all capsules.
Quick answers about EJA130E-JMS5J-912NB
- What is the maximum static pressure of EJA130E-JMS5J-912NB? Maximum working pressure is 32 MPa (4500 psi) with B7 bolting, code J.
- What differential span does the M capsule cover? 1 to 100 kPa, with a range of minus 100 to 100 kPa.
- Are process connectors included? No. Code 5 leaves the 1/4 NPT female cover flange ports for the impulse piping.
- How heavy is the transmitter? The datasheet gives 6.8 kg without the integral indicator and mounting bracket.
- What is the burst pressure? 132 MPa (19100 psi) according to the datasheet.
Documents and quotation
Give the line pressure and differential span when you send your enquiry.
The datasheet for this transmitter, Yokogawa GS 01C31B04-01EN, is supplied as a PDF with the listing. For a quotation, send the full part number EJA130E-JMS5J-912NB, the quantity, the tag numbers, the line pressure and the differential pressure range. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and delivery time are confirmed per RFQ.
Spares and Lifecycle Considerations
For critical service, many plants hold one Yokogawa EJA130E-JMS5J-912NB as an operational spare rather than waiting for a failure. When you plan spares, look at how many identical pressure transmitters units are installed, how long a replacement would take to arrive, and the cost of an unplanned stop. Store spare units in their original packaging in a dry, temperature-controlled area and record the part number and serial number in your maintenance system. We can quote single units or a small spares package and confirm the lead time for each item in writing.
Datasheets & Documents
- Datasheet Yokogawa EJA130E-JMS5J-912NB High Static Pressure DP Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA130E-JMS5J-912NB High Static Pressure DP
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum static pressure of EJA130E-JMS5J-912NB?
Maximum working pressure is 32 MPa (4500 psi) with B7 bolting, code J.
02What differential span does the M capsule cover?
1 to 100 kPa, with a range of minus 100 to 100 kPa.
03Are process connectors included?
No. Code 5 leaves the 1/4 NPT female cover flange ports for the impulse piping.
04How heavy is the transmitter?
The datasheet gives 6.8 kg without the integral indicator and mounting bracket.
05What is the burst pressure?
132 MPa (19100 psi) according to the datasheet.


















Reviews
There are no reviews yet.