Brand:

AMETEK 71842SE WDG-HPII Ceramic Filter with 316SS Perforated Sheath

Description

AMETEK 71842SE overview

AMETEK 71842SE is a ceramic filter assembly with a 316 stainless steel perforated sheath and bushing for the Thermox WDG-HPII analyzer. The listing names the ceramic filter, the 316 stainless steel perforated sheath and the bushing as the elements of the assembly. The AMETEK listing places it in the WDG-HPII filter group, so it is not interchangeable with WDG-V probe filters. Probes in dusty combustion processes need regular filter changes, and maintenance teams quote the exact number when the existing filter has plugged.

Thermox WDG-series zirconia analyzers measure excess oxygen, and in the combustibles versions the heated detectors add combustibles and methane. AMETEK Process Instruments publishes the replacement parts for these analyzers on its parts store, where each kit and assembly is identified by its own number.

Key features of 71842SE

  • Ceramic filter element for the WDG-HPII analyzer
  • 316 stainless steel perforated sheath for mechanical protection
  • Supplied with bushing according to the listing
  • Perforated tube visible in the product photograph
  • Listed in the WDG-HPII filter group by AMETEK
  • Not the same part as the WDG-V filters

71842SE technical specifications

Item Detail
Part number 71842SE
Description Assembly, filter, ceramic, with 316 SS perforated sheath and bushing
Category (AMETEK) Filters, WDG-HPII ceramic with 316SS perforated sheath and bushing
Filter medium Ceramic
Sheath 316 SS perforated
Analyzer Thermox WDG-HPII

The details above come from the AMETEK parts listing for 71842SE. Always check the nameplate and serial number of the installed analyzer, because options and upgrade status change from unit to unit and the listing does not replace the service manual.

Typical applications in oil and gas, utilities, water and manufacturing

Zirconia oxygen analyzers of this family are used on fired heaters, boilers and furnaces where excess oxygen is monitored for combustion control. Across Oman and the GCC the same duty appears in refineries, gas processing plants, power stations and process heaters.

Where 71842SE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 71842SE

Confirm the model and detector configuration, and give the analyzer serial number when requesting a quotation, since probe parts and some kits are specified by serial number or by upgrade status.

Part number 71842SE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Let the probe cool and isolate the analyzer from the process, then withdraw the probe assembly according to the service manual for your analyzer. Remove the used filter assembly, fit 71842SE with its bushing and any hardware supplied, and reinstall the probe with fresh gaskets where required. Check for leaks and verify the oxygen reading after warm-up and calibration.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 71842SE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

Filter condition governs sample flow and response speed. Inspect during planned shutdowns, replace when plugged and keep a spare for dusty services such as cement, boilers and heaters burning heavy fuels.

Related products and ordering notes

Review the maintenance kits 7002-485-TE and 7002-483-TE and the sample probes by serial number when planning a service turnaround for a WDG-HPII analyzer.

For a spare parts plan, list 71842SE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Parts for this analyzer line are identified by the numbers in the AMETEK parts listing, and several of them replace earlier numbers or differ only by one detector or one gasket. When you ask about 71842SE, state whether the analyzer measures oxygen only, oxygen with combustibles, or oxygen with combustibles and methane, and say whether the combustibles detectors are of the hot wire type. This avoids ordering a kit whose contents do not match the installed hardware, and it allows the technical check to be completed before the shutdown work is scheduled.

If only one wear item has failed, the individual numbers named in the listing can be requested instead of a full set. If the analyzer is due for a complete service, a single kit number such as 71842SE reduces the number of purchase lines, keeps related parts together in one delivery and simplifies receiving inspection against the contents named in the AMETEK listing.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 71842SE

  • What is AMETEK 71842SE? It is a probe filter assembly for the Thermox WDG-HPII analyzer, listed by AMETEK in the group WDG-HPII ceramic with 316SS perforated sheath and bushing.
  • What does 71842SE protect? It keeps particulate in flue gas out of the sample path of the analyzer probe.
  • Is 71842SE the same as the WDG-V probe filter? No. AMETEK lists the WDG-HPII filters in a separate group from the WDG-V filters, so match the part to the analyzer.

Documents and quotation

No datasheet is attached for this part, because the manufacturer publishes it through the parts listing and the analyzer service manual. To request pricing and lead time for AMETEK 71842SE, send the RFQ with the part number 71842SE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 71842SE WDG-HPII Ceramic Filter with 316SS

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 71842SE?
It is a probe filter assembly for the Thermox WDG-HPII analyzer, listed by AMETEK in the group WDG-HPII ceramic with 316SS perforated sheath and bushing.
02What does 71842SE protect?
It keeps particulate in flue gas out of the sample path of the analyzer probe.
03Is 71842SE the same as the WDG-V probe filter?
No. AMETEK lists the WDG-HPII filters in a separate group from the WDG-V filters, so match the part to the analyzer.
04What details should I send for 71842SE?
Send the analyzer model and serial number along with 71842SE, because probe parts are specified by serial number in AMETEK documentation.
05How do I request a quotation for 71842SE?
Send the part number 71842SE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.