- Automation & ControlView all 2,680 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Motor Soft Starters
- Safety Switches & Guard Locking
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: SERVOMEX
Servomex 2344-2054 1/4 in OD SS Adaptor for Oxy 1900
Description
Servomex 2344-2054 overview: stainless steel adaptor for 1/4 inch outside diameter tube for the Oxy 1900 digital analyser
The Servomex 2344-2054 is a stainless steel adaptor for 1/4 inch outside diameter tubing, listed in the spares table of the 1900 Digital oxygen analyser manual. It is a tubing adaptor sized for imperial tube, relevant on plants whose instrument tubing follows American or mixed standards.
The image on this page shows the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser) that this item belongs to, so that buyers can recognise the equipment family; it is not a close-up of the stainless steel adaptor for 1/4 inch outside diameter tube itself. Every detail on this page is taken from the manufacturer documentation for that equipment, and where a value is not stated there, we have left it out rather than guess.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Servomex 2344-2054 so that maintenance and procurement teams can quote the exact number that appears in the manufacturer manual, which matters because instrument spares are rarely interchangeable by description alone.
Key features of 2344-2054
- Exact manufacturer part number 2344-2054, taken from the documented spares or parts list of the analyser.
- Item: stainless steel adaptor for 1/4 inch outside diameter tube.
- Intended equipment: SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser).
- The manual lists two adaptor sizes: 1/4 inch outside diameter (2344-2054) and 6 mm outside diameter (2346-3073).
- Supplied against a quotation request that confirms the analyser model, serial number and quantity.
Technical specifications for 2344-2054
The first table records the data for the part itself, as given in the manufacturer documentation. The second table records the main data of the host equipment, which helps confirm that the part suits the installation. No pricing is shown on this page, and values not published in the documentation are not included.
Part data
| Item | Value |
|---|---|
| Part number | 2344-2054 |
| Description | Adaptor, 1/4 inch outside diameter, stainless steel |
| Tube size | 1/4 inch OD |
| Fits | 1900 Digital O2 Gas Analyser |
Host equipment data
| Item | Value |
|---|---|
| Analyser family | SERVOTOUGH Oxy 1900, 1900 Digital O2 Gas Analyser |
| Analyser dimensions (H x W x D) | 235 x 448 x 229 mm |
| Analyser mass | 26 kg |
| Sample flow, standard inlet/outlet T piece | 50 to 250 ml/min |
| Sample flow, high flow bypass T piece | 50 to 70 l/h (60 l/h nominal) |
| Ambient temperature, operation | -10 to 50 degrees C |
| Ingress protection | IP65 |
| Supply | 100 to 120 V a.c. or 220 to 240 V a.c., 50 to 60 Hz, maximum 50 VA |
Typical applications in oil and gas, utilities, water and manufacturing
The 1900 Digital analyser measures oxygen in clean, non-corrosive, oil-free sample gas and is housed for hazardous-area installation, so it is typically found on inerting and blanketing lines, nitrogen generation and purity checks, solvent and chemical plant vapour spaces and similar duties. In Oman and the wider GCC that translates into refineries, gas processing trains, petrochemical units, LNG and storage terminals, plus industrial gas and manufacturing sites where a few percent of oxygen decides whether a line is safe to run.
Gulf conditions add their own demands: high ambient temperature, fine desert dust and coastal humidity all age seals, filters and electronics faster than in temperate climates. A planned stock of spares such as 2344-2054 therefore pays back quickly, because an analyser that is waiting for a part can hold up a start-up, a safety check or an emissions report.
Selection and compatibility notes
The manual lists two adaptor sizes: 1/4 inch outside diameter (2344-2054) and 6 mm outside diameter (2346-3073). Pick the one that matches your process tubing, not the one that looks similar. Both are stainless steel, which suits the clean, non-corrosive sample gases the analyser is intended for.
The manual for the 1900 Digital analyser states that the unit is not suitable for oxygen-enriched sample gases and that sample gas must be clean, non-corrosive, free from oil and condensate and with particulates smaller than 3 microns, which is exactly why the consumable parts at the sample inlet matter. The same manual warns that spares other than those it specifies can damage the analyser and invalidate its certification, so confirm the analyser model and transducer type before ordering.
When you send an enquiry for 2344-2054, include the analyser model, the serial number or order code, the supply voltage if relevant, and a photograph of the nameplate. That information lets us confirm the match against the manufacturer documentation before a quotation is issued.
Installation and commissioning of 2344-2054
Fit the adaptor to the analyser connection and the tubing to the adaptor, keeping the sample line short, clean and leak free. Because the analyser is measuring oxygen, any leak on the sample path will let air in and cause a high reading, so leak test every new joint before putting the analyser back on line.
As with any work on process analysers, follow the site permit-to-work system, isolate sample and electrical supplies, and use only the procedures in the manufacturer manual. After fitting 2344-2054, return the analyser to service in the order the manual describes and confirm the reading with a suitable reference gas before relying on the output for control or alarms.
Maintenance and service life
Check sample connections at each routine inspection, together with the inlet filter. Replace any adaptor that shows damaged threads or corrosion, and record the part number 2344-2054 in your spares register so an exact match can be re-ordered.
Keep a simple maintenance log for each analyser listing the date, the action and the part number used. When 2344-2054 has been changed, a short note makes it easy to plan the next replacement and gives the manufacturer or an engineer useful history if a fault returns.
Related products and ordering notes
Other items from the same manual that are often ordered with 2344-2054 include 2377-3862 (20 micron stainless steel inlet filter), 2323-7803 (Viton inlet filter O-ring), 2323-7928 (Chemraz inlet filter O-ring), 204629 (2 A fuse for supply fuse position F101), 2531-2630 (1 A fuse for supply fuse position F101), 2346-3073 (stainless steel adaptor for 6 mm outside diameter tube). Each is a separate part number and is quoted separately. Combining them in one enquiry avoids repeated shipments and shortens the shutdown window.
Many of these numbers belong to older analyser generations. If the manufacturer has superseded a part, we will tell you only if the manufacturer documentation names the replacement. Otherwise we will confirm availability and lead time before you commit to an order.
Frequently asked questions
The questions below summarise what buyers most often ask about 2344-2054.
What is 2344-2054? 2344-2054 is the manufacturer part number for the stainless steel adaptor for 1/4 inch outside diameter tube used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
Which equipment does 2344-2054 fit? It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
Can Seven Star LLC supply 2344-2054 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
Is a datasheet or manual available for 2344-2054? The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
What details should I send with my RFQ for 2344-2054? Send the part number 2344-2054, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.
Documents and quotation
The official Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (01910001A) is attached to this page as a PDF. The Spares chapter (section 10, manual page 65) lists part 2344-2054 as the 1/4 inch outside diameter stainless steel gas connection adaptor. Include part number 2344-2054 and the analyser model and serial number in your inquiry and we will reply with availability and a written quotation.
Other Models in the Servomex 1900 Range
Seven Star LLC supplies models from the Servomex 1900 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Servomex 2377-3862 Inlet Filter 20 um SS for Oxy 1900 | Gas Analyzer Systems | View details |
| Servomex 2323-7803 Viton O-Ring for Oxy 1900 Inlet Filter | Gas Analyzer Systems | View details |
| Servomex 204629 Fuse F101 2 A for Oxy 1900 (100-120 V) | Gas Analyzer Systems | View details |
| Servomex 2531-2630 Fuse F101 1 A for Oxy 1900 (220-240 V) | Gas Analyzer Systems | View details |
| Servomex 2344-2054 1/4 in OD SS Adaptor for Oxy 1900 | Gas Analyzer Systems | You are viewing this model |
Datasheets & Documents
- Datasheet Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (official PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.
Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.
SERVOMEX company profile
| Founded | 1952, United Kingdom |
|---|---|
| Founders | Richard Steel, John Crockett and Ronald Mudie |
| Headquarters | Jarvis Brook, Crowborough, East Sussex |
| Ownership | Spectris plc, since 1999 |
| Key technologies | Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981) |
| Product families | MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers |
Milestones
- 1952: Servomex is founded.
- 1961: The first Servomex paramagnetic oxygen analyser is introduced.
- 1981: Servomex introduces zirconia oxygen sensors.
- 1999: Spectris acquires Servomex.
Servomex analyzer families listed
Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:
- SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
- SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
- SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
- SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
- SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
- SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer
A flow alarm relay box for the 2700 flue gas analyzer is also listed.
Where Servomex gas analyzers are used
Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.
SERVOMEX products we list
Ordering Servomex analyzers and spares: what we need
A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.
Facts checked against Servomex's own 70-year history and company profiles, October 2026.
Browse SERVOMEX products by category: Gas Analyzer Systems, Gas Analyzer Accessories, Portable Test & Measurement.
FAQ
Questions about the Servomex 2344-2054 1/4 in OD SS Adaptor for Oxy 1900
Answers from our engineering team on installation, compatibility and integration.
01What is 2344-2054?
2344-2054 is the manufacturer part number for the stainless steel adaptor for 1/4 inch outside diameter tube used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
02Which equipment does 2344-2054 fit?
It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
03Can Seven Star LLC supply 2344-2054 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
04Is a datasheet or manual available for 2344-2054?
The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
05What details should I send with my RFQ for 2344-2054?
Send the part number 2344-2054, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.


















Reviews
There are no reviews yet.