Schneider Electric RXM4LB1BD RXM 4 C/O Relay 24 V DC

Description

RXM4LB1BD: Harmony RXM 4 C/O relay with 24 V DC coil

The RXM4LB1BD is a Schneider Electric Harmony RXM miniature plug-in relay with four changeover (C/O) contacts and a 24 V DC coil. This version is without a status LED and has no lockable test button. Its datasheet lists a conventional enclosed thermal current of 3 A, flat faston-type pins and a net weight of 33 g. Seven Star LLC supplies the RXM4LB1BD in Oman and the GCC as an independent supplier based in Muscat.

Reading the references in this family, the digit after RXM identifies the 4 C/O contact set, the letter pair identifies the contact family (LB: 3 A, silver alloy contacts), the next digit separates the versions without LED (1 without LED), and the last two characters are the coil code, here BD for 24 V DC. This is our reading of the pattern across the references we reviewed, not a published ordering table, so confirm the full reference before ordering.

Selection checklist for the RXM4LB1BD

  • Coil: 24 V DC, with the real supply inside 19.2–26.4 V DC V DC.
  • Load: up to 3 A thermal current, checked per contact against the AC or DC rating.
  • Indication: no LED on this version.
  • Manual override: no test button on this version.
  • Base: an RXM-compatible socket with the right terminal style.
  • Quantity: relays are sold in indivisible quantities, so confirm the pack size with us.

Technical specifications of the RXM4LB1BD

Parameter Specification
Manufacturer / part number Schneider Electric / RXM4LB1BD
Range Harmony Electromechanical Relays, RXM series
Product type Miniature plug-in relay
Contacts 4 C/O
Status LED Without
Control type Without lockable test button
Control circuit voltage [Uc] 24 V DC
Rated operational voltage limits 19.2–26.4 V DC V DC
Drop-out voltage threshold ≥ 0.1 Uc DC
Average coil resistance 640 Ohm at 23 °C ± 10 %
Average coil consumption 0.9 W, DC
Conventional enclosed thermal current [Ithe] 3 A
Maximum switching capacity 750 VA AC 84 W DC
Minimum switching capacity 25 mW subject to switching frequency, environment or expected reliability level etc
Contacts material Silver alloy (Ag/Ni)
Mechanical durability 20000000 cycles
Electrical durability 200000 cycles resistive load 23 °C 100000 cycles resistive load at 55 °C
Insulation voltage [Ui] 250 V conforming to IEC
Pin shape Flat (faston type)
Operating position Any position
Operating rate ≤ 1200 cycles/hour under load; ≤ 18000 cycles/hour no-load
Net weight 33 g
Storage temperature -40–85 °C
Warranty 18 months

Installing and maintaining the RXM4LB1BD

Plug the RXM4LB1BD into a compatible socket with the power off, check that the flat pins seat fully, and fit a retaining clamp or similar where vibration is expected. The datasheet allows any operating position. Operating temperature for this version is listed as not stated on the datasheet for operation; storage is -40–85 °C.

Relays are consumable parts. In service, log the contact cycles of heavily used circuits and replace on a schedule, and keep a stock of the same coil voltage, since a wrong-voltage swap can burn out a coil or make the relay fail to pick up.

Indication and manual operation on the RXM4LB1BD

The RXM4LB1BD has neither a status LED nor a lockable test button, which gives the plain version of the RXM relay for panels where indication is provided elsewhere and manual override is not wanted.

When choosing between versions, remember that these features are fixed on the relay itself. A relay without LED cannot be upgraded and has to be replaced by the LED variant if indication is later required, and the same goes for the test button.

The RXM4LB1BD among RXM 4 C/O relays

Siblings in this lane differ in coil voltage, contact rating, LED and test button. The table lists neighbouring references.

Part number Coil Rated thermal current Status LED Lockable test button
RXM4LB1B7 24 V AC 3 A Without No
RXM4LB1BD (this page) 24 V DC 3 A Without No
RXM4LB1JD 12 V DC 3 A Without No
RXM4LB1P7 230 V AC 3 A Without No
RXM4LB2B7 24 V AC 3 A With No
RXM4LB2BD 24 V DC 3 A With No
RXM4LB2CD 36 V DC 3 A With No

Sockets such as the RXZE2M114, RXZE2M114M and RXZE2S114M accept RXM2 and RXM4 relays, and the RXZ-series accessories are matched to the same relay body.

Coil of the RXM4LB1BD: 24 V DC

24 volts is the most common control voltage in PLC cabinets and instrument marshalling panels, so this coil value fits the output of a typical controller or supply directly. The datasheet gives operating voltage limits of 19.2–26.4 V DC V DC, which is the window within which the coil should be driven. A coil resistance of 640 Ohm at 23 °C ± 10 % and a consumption of 0.9 W, DC describe how much the control source must supply.

The drop-out threshold is listed as ≥ 0.1 Uc DC, meaning the relay releases when the coil voltage falls to that fraction of 24 V DC. On DC circuits, check how the supply behaves during dips and ripple, because a voltage that hovers between pick-up and drop-out causes chatter. DC coils are polarised in the sense that a suppression diode across the coil must be fitted with the correct polarity, if one is used.

Contact capability of the RXM4LB1BD

The four C/O contacts use Silver alloy (Ag/Ni) material. The datasheet gives 3 A at 250 V AC and 3 A at 28 V DC on the normally open side, with 1.5 A on the normally closed side. The maximum switching capacity is 750 VA AC 84 W DC. The minimum switching figures are 25 mW, 5 mA and 5 V, each subject to switching frequency and the environment.

The electrical durability entry reads 200000 cycles resistive load 23 °C 100000 cycles resistive load at 55 °C, against a mechanical durability of 20000000 cycles. Inductive loads such as contactor coils and solenoids reduce contact life, so fit RC or varistor suppression across AC loads and a free-wheeling diode across DC loads, and do not read the resistive life as a guarantee for every load.

Information to send with an RFQ for the RXM4LB1BD

  • Exact reference RXM4LB1BD and the quantity.
  • Coil supply voltage and type, 24 V DC here.
  • Load type and current on the contacts.
  • Socket or base type already installed.
  • Other coil voltages or LED versions needed in the same order.
  • Delivery location and timeline.

For critical duties, keep one tested spare of every relay and base type on site, and label the shelf location in the maintenance system so that outage crews can find it quickly.

If the panel is later modified, update the drawings with the exact references fitted, because mismatches between drawings and hardware cost more time than almost any other documentation fault.

When a project is tendered with alternates, state the exact accepted references in the bill of materials, since mixed substitutions between similar-looking relays and bases are a common cause of rework at site.

Store spares in their original packaging in a dry cabinet, away from direct sun and corrosive atmospheres, so that terminals and pins stay clean until they are needed.

Documents and quotation

The Schneider Electric datasheet for the RXM4LB1BD is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.

Send us the reference RXM4LB1BD, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.

Other Models in the Schneider Harmony Rxm4 Range

Seven Star LLC supplies models from the Schneider Harmony Rxm4 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric RXM4AB1B7 RXM 4 C/O Relay 24 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB1BD RXM 4 C/O Relay 24 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB1E7 RXM 4 C/O Relay 48 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB1ED RXM 4 C/O Relay 48 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB1F7 RXM 4 C/O Relay 120 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB1FD RXM 4 C/O Relay 110 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB1JD RXM 4 C/O Relay 12 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB1P7 RXM 4 C/O Relay 230 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB1U7 RXM 4 C/O Relay 240 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB2B7 RXM 4 C/O Relay 24 V ACContactors & Overload RelaysView details
Schneider Electric RXM4AB2BD RXM 4 C/O Relay 24 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB2FD RXM 4 C/O Relay 110 V DCContactors & Overload RelaysView details
Schneider Electric RXM4AB2JD RXM 4 C/O Relay 12 V DCContactors & Overload RelaysView details
Schneider Electric RXM4GB2BD RXM 4 C/O Relay 24 V DCContactors & Overload RelaysView details
Schneider Electric RXM4LB1B7 RXM 4 C/O Relay 24 V ACContactors & Overload RelaysView details
Schneider Electric RXM4LB1BD RXM 4 C/O Relay 24 V DCContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric RXM4LB1BD Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric RXM4LB1BD RXM 4 C/O Relay 24 V DC

Answers from our engineering team on installation, compatibility and integration.

01What coil does the RXM4LB1BD use?
A 24 V DC coil with operating voltage limits of 19.2–26.4 V DC V DC. The datasheet lists a drop-out threshold of >= 0.1 Uc DC and an average coil resistance of 640 Ohm at 23 °C +/- 10 %.
02What contacts does the RXM4LB1BD have?
Four C/O contacts with Silver alloy (Ag/Ni) material and a conventional enclosed thermal current of 3 A. The maximum switching capacity is 750 VA AC 84 W DC.
03Does the RXM4LB1BD have an LED or test button?
Status LED: without. Control type: without lockable test button.
04What socket fits the RXM4LB1BD?
The datasheet lists flat faston-type pins and RXM compatibility. Sockets such as RXZE2M114 and RXZE2S114M are listed for RXM4 relays; confirm the terminal style you need.
05How long does the RXM4LB1BD last?
Mechanical durability is 20000000 cycles. Electrical durability is listed as 200000 cycles resistive load 23 °C 100000 cycles resistive load at 55 °C.