LADN22: four-contact block with two NO and two NC contacts

The LADN22 is a Schneider Electric TeSys D front auxiliary contact block with two normally open and two normally closed contacts. It is the balanced four-contact block, and the most common choice when a contactor needs both a self-hold and several interlock or signal circuits. Seven Star LLC supplies the LADN22 in Oman and the GCC as an independent supplier based in Muscat.

At 44 mm wide, 48 mm high and 42 mm deep, with a net weight of 0.05 kg, the block takes the full width of the front face of a small contactor.

Technical specifications of the LADN22

Parameter Specification
Manufacturer / part number Schneider Electric / LADN22
Description Product datasheet Auxiliary contact block, TeSys D, 2NO + 2NC, front mounting, screw terminals.
Range TeSys; TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D
Mounting location Front
Pole contact composition 2 NO + 2 NC
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25 to 400 Hz
[Ie] rated operational current 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA
[Ith] conventional free air thermal 10 A (at 60 °C)
Standards EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certifications CB Scheme; UL; CSA; CCC; EAC; UKCA
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms; are subject to change – check with your local distributor.
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible without cable end
Height 48 mm
Width 44 mm
Depth 42 mm
Net weight 0.05 kg
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature (operation, as listed) -5 to 60 °C
Operating altitude 3000 m

The 2 NO + 2 NC balance of the LADN22

Two NO contacts handle sealing and status; two NC contacts handle interlocks. That balance covers a reversing starter with a mechanical-plus-electrical interlock, or a star-delta contactor that needs to block other contactors in the sequence.

Compared with using two LADN11 blocks, a single LADN22 occupies one mounting position, which matters on contactors that accept only one front block.

Compatibility and electrical data of the LADN22

Rated operational voltage is 690 V AC at 25 to 400 Hz, with conventional thermal current of 10 A at 60 °C. Rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. Making capacity is 140 A AC and 250 A DC, protection is a 10 A gG fuse, mechanical durability is 30 Mcycles, and the minimum switching level is 5 mA at 17 V. The non-overlap time between the NC and NO contacts is 1.5 ms on energisation and on de-energisation.

Range compatibility in the datasheet: TeSys D CAD and LC1D, TeSys F LC1F and CR1F, TeSys Deca CAD and LC1D. Standards include EN/IEC 60947-5-1, UL 60947-5-1 and CSA C22.2 No 60947-5-1, and certifications listed are CB Scheme, UL, CSA, CCC, EAC and UKCA.

LADN family: the LADN22 compared with its siblings

All six references below are front-mounting TeSys D blocks with screw clamp terminals; they differ in contact pattern and width.

Reference Contacts Width Protection
LADN11 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN11G 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN20 2 NO 26 mm IP20 conforming to IEC 60529
LADN22 2 NO + 2 NC 44 mm IP20 conforming to IEC 60529
LADN31 3 NO + 1 NC 44 mm IP2X conforming to IEC 60529
LADN40 4 NO 44 mm IP2X conforming to IEC 60529

LADN22 specification checklist

  • Four contacts: 2 NO + 2 NC.
  • Width 44 mm; check the free space on the contactor front.
  • Use LADN31 for 3 NO + 1 NC and LADN40 for 4 NO.
  • Screw clamp terminals; two conductors per terminal within the datasheet range.
  • Net weight 0.05 kg.

Terminal and torque details for the LADN22

Each of the eight terminals takes 1 to 4 mm² flexible with ferrule for single conductors, or 1 to 2.5 mm² for two. Tighten at 1.7 N.m.

Mark the NO and NC pairs on the schematic and test each pair under both contactor states. With eight terminals in a small block, a mistaken cross-wire is more likely than a failed contact.

LADN22 in Oman and GCC panels

The block is a favourite in star-delta and reversing starters on pumps and compressors at water, power and oil and gas sites, where the control scheme needs interlocks and several signals on the same contactor.

Spare LADN22 blocks are cheap insurance for shutdowns; a loose or burnt contact on a main contactor is a typical overhaul finding.

Information to send with an RFQ for the LADN22

  • Full reference and quantity required
  • Contactor model the block mounts on
  • Contact arrangement needed (NO and NC count)
  • Control voltage and load of each circuit
  • Delivery location and timing

Documents and quotation

A datasheet for the LADN22 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys D Ladn Range

Seven Star LLC supplies models from the Se Tesys D Ladn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LADN11 TeSys D 1 NO + 1 NC Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN11G TeSys D 1 NO + 1 NC EN 50012 BlockContactors & Overload RelaysView details
Schneider Electric LADN20 TeSys D 2 NO Front Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN22 TeSys D 2 NO + 2 NC Contact BlockContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Schneider Electric LADN22 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LADN22 TeSys D 2 NO + 2 NC

Answers from our engineering team on installation, compatibility and integration.

01What contacts does the LADN22 have?
Two normally open and two normally closed.
02How wide is the LADN22?
44 mm wide, 48 mm high, 42 mm deep. See the datasheet linked on this page for the full figures.
03How heavy is the LADN22?
0.05 kg. See the datasheet linked on this page for the full figures.
04What is the thermal current?
10 A at 60 degrees C. See the datasheet linked on this page for the full figures.
05What fuse protects the LADN22 contacts?
A 10 A gG fuse is listed in the datasheet.