Schneider Electric LADN20 TeSys D 2 NO Front Contact Block

Description

LADN20: two normally open front contacts for TeSys D

The LADN20 is a Schneider Electric TeSys D front auxiliary contact block with two normally open contacts and screw clamp terminals. It is the choice when a contactor only needs closing signals: a self-hold plus an indication, or two independent run signals. Seven Star LLC supplies the LADN20 in Oman and the GCC as an independent supplier based in Muscat.

The 20 reads as two NO and zero NC. At 26 mm the block is as slim as the LADN11, and the datasheet lists the same terminals, ratings and certification group.

Technical specifications of the LADN20

Parameter Specification
Manufacturer / part number Schneider Electric / LADN20
Description Product datasheet Auxiliary contact block, TeSys D, 2NO, front mounting, screw clamp terminals
Range TeSys; TeSys Deca
Product name TeSys Deca
Product or component type Auxiliary contact block
Device short name LADN
Range compatibility TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D
Mounting location Front
Pole contact composition 2 NO
Contacts operation Instantaneous
[Ue] rated operational voltage 690 V AC 25 to 400 Hz
[Ie] rated operational current 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13
[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA
[Ith] conventional free air thermal 10 A (at 60 °C)
Standards EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ
Product certifications CB Scheme; UL; CSA; CCC; EAC; UKCA
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms; are subject to change – check with your local distributor.
Protection type GG fuse 10 A
Mechanical durability 30 Mcycles
Minimum switching current 5 mA
Minimum switching voltage 17 V
Non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections – terminals Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible without cable end
Height 48 mm
Width 26 mm
Depth 42 mm
Environmental characteristic Normal environment
IP degree of protection IP20 conforming to IEC 60529
Ambient air temperature (operation, as listed) -5 to 60 °C
Operating altitude 3000 m

LADN20 selection notes

  • Two NO contacts, no NC.
  • 26 mm wide and 48 mm high.
  • Closing signals at up to 690 V AC, 6 A at 120 V AC-15.
  • Check low-level loads against the 5 mA / 17 V minimum.
  • Consider the LADN11 if one interlock is wanted.

Where two NO contacts of the LADN20 are better than 1 NO + 1 NC

Many control schemes contain no interlock at all. A fan starter with a single start and stop button needs a seal-in contact and perhaps one signal to a building system; both are normally open. Fitting an NC contact there only adds a wire that nobody uses.

Where a design later needs an interlock, the NC can be added by stacking a second block, as long as the contactor width allows it.

Electrical profile of the LADN20

Rated operational voltage is 690 V AC at 25 to 400 Hz, with conventional thermal current of 10 A at 60 °C. Rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. Making capacity is 140 A AC and 250 A DC, protection is a 10 A gG fuse, mechanical durability is 30 Mcycles, and the minimum switching level is 5 mA at 17 V. The non-overlap time between the NC and NO contacts is 1.5 ms on energisation and on de-energisation.

The block fits TeSys D and TeSys Deca contactors and CAD relays, as well as TeSys F LC1F and CR1F, according to the datasheet. Conductors of 1 to 4 mm² flexible are accepted with a ferrule.

Commissioning the LADN20

Clip the block on, tighten the terminals to 1.7 N.m, and test: with the contactor off both contacts should read open; after closing it by hand both should read closed.

Label the terminals on the schematic as the drawing says, and note this in the as-built records.

LADN family: the LADN20 compared with its siblings

All six references below are front-mounting TeSys D blocks with screw clamp terminals; they differ in contact pattern and width.

Reference Contacts Width Protection
LADN11 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN11G 1 NO + 1 NC 26 mm IP20 conforming to IEC 60529
LADN20 2 NO 26 mm IP20 conforming to IEC 60529
LADN22 2 NO + 2 NC 44 mm IP20 conforming to IEC 60529
LADN31 3 NO + 1 NC 44 mm IP2X conforming to IEC 60529
LADN40 4 NO 44 mm IP2X conforming to IEC 60529

LADN20 uses in Oman and the GCC

It is common in simple fan and pump starters in buildings, where one contact seals in the coil and the other feeds the BMS run status.

Another use is as a feedback contact on a main contactor to start an upstream or downstream device after it has closed.

Information to send with an RFQ for the LADN20

  • Full reference and quantity required
  • Contactor model the block mounts on
  • Contact arrangement needed (NO and NC count)
  • Control voltage and load of each circuit
  • Delivery location and timing

Documents and quotation

A datasheet for the LADN20 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.

Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Tesys D Ladn Range

Seven Star LLC supplies models from the Se Tesys D Ladn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LADN11 TeSys D 1 NO + 1 NC Contact BlockContactors & Overload RelaysView details
Schneider Electric LADN11G TeSys D 1 NO + 1 NC EN 50012 BlockContactors & Overload RelaysView details
Schneider Electric LADN20 TeSys D 2 NO Front Contact BlockContactors & Overload RelaysYou are viewing this model
Schneider Electric LADN22 TeSys D 2 NO + 2 NC Contact BlockContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric LADN20 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LADN20 TeSys D 2 NO Front

Answers from our engineering team on installation, compatibility and integration.

01What contacts does the LADN20 have?
Two normally open contacts. Check that this arrangement matches your control circuit before ordering.
02What is the width of the LADN20?
26 mm. See the datasheet linked on this page for the full figures.
03What is the making capacity?
140 A AC and 250 A DC per the datasheet.
04What is the torque for terminals?
1.7 N.m. See the datasheet linked on this page for the full figures.
05Which ambient range applies?
-5 to 60 degrees C. See the datasheet linked on this page for the full figures.