Brand: Schneider Electric
Schneider Electric ATV630U07N4 Altivar Process 0.75 kW Drive
Description
ATV630U07N4 smallest Altivar Process drive for process machines
The ATV630U07N4 is a Schneider Electric product listed in the datasheet as: Variable Speed Drive, Altivar Process ATV600, ATV630, 0.75kW, 1hp, 380 to 480V, IP21, UL type 1. The Altivar Process ATV630 is the flagship drive for pumps, fans and compressors in process industry, and this 0.75 kW (1 hp) unit is the entry size of that range. It is selected when a small process motor needs the same network functions, graphic keypad and energy features as the large drives of the family. Seven Star LLC supplies the ATV630U07N4 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: ATV630 is the Altivar Process wall or floor drive, U07 is the 0.75 kW rating, and N4 is the 380 to 480 V three-phase supply class. The datasheet title adds IP21 / UL type 1 enclosure, so the drive does not need an extra cabinet for dust-free indoor mounting.
Technical specifications of the ATV630U07N4
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / ATV630U07N4 |
| Description | Variable Speed Drive, Altivar Process ATV600, ATV630, 0.75kW, 1hp, 380 to 480V, IP21, UL type 1 |
| Range of Product | Altivar Process ATV600 |
| Product Specific Application | Process and utilities |
| Product or Component Type | Variable speed drive |
| Variant | Standard version |
| Device short name | ATV630 |
| Mounting Mode | Wall mount |
| Communication Port Protocol | Modbus TCP; Ethernet; Modbus serial |
| [Us] rated supply voltage | 380 to 480 V |
| Relative symmetric mains voltage | 10 % |
| Relative symmetric network | 5% |
| nominal output current | 2.2 A |
| IP degree of protection | IP21 IEC 61800-5-1; IP21 IEC 60529 |
| Product destination | Asynchronous motors; Synchronous motors |
| EMC filter | Integrated 50 m IEC 61800-3 category C2; Integrated 150 m IEC 61800-3 category C3 |
| Degree of protection | UL type 1 UL 508C |
| Type of cooling | Forced convection |
| Supply frequency | 50 to 60 Hz (tolerance -5 % / +5 %) |
| Motor power kW | 0.75 kW normal duty; 0.37 kW heavy duty |
| Maximum Horse Power Rating | 1 hp normal duty; 0.5 hp heavy duty |
| Line current | 1.5 A 380 V normal duty; 1.3 A 480 V normal duty; 0.9 A 380 V heavy duty; 0.8 A 480 V heavy duty |
| Continuous output current | 2.2 A 4 kHz normal duty; 1.5 A 4 kHz heavy duty |
| Speed drive output frequency | 0.1 to 500 Hz |
| Safety function | STO (safe torque off) SIL 3 |
| Option card | Slot A communication module, Profibus DP V1; Slot A communication module, PROFINET; Slot A communication module, DeviceNet |
| Discrete input number | 8 |
| Discrete input type | DI7, DI8 programmable as pulse input 0 to 30 kHz, 24 V DC <= 30 V |
| Discrete input logic | Positive logic (source) DI1–DI8, < 5 V, > 11 V; Negative logic (sink) DI1–DI8, > 16 V, < 10 V |
| Discrete output number | 0 |
| Discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA |
| Analogue input number | 3 |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage 0 to 10 V DC 31.5 kOhm 12 bits |
| Analogue output number | 2 |
| Analogue output type | Software-configurable voltage AQ1, AQ2 0 to 10 V DC 470 Ohm 10 bits; Software-configurable current AQ1, AQ2 0 to 20 mA 10 bits |
| Relay output number | 3 |
| Relay output type | Configurable relay logic R1 fault relay NO/NC 100000 cycles; Configurable relay logic R2 sequence relay NO 100000 cycles |
| Maximum switching current | Relay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC; Relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC |
| Minimum switching current | Relay output R1, R2, R3 5 mA 24 V DC |
| Phase | 3 phase |
| Physical interface | Ethernet; 2-wire RS 485 |
| Method of access | Slave Modbus TCP |
Motor, supply and enclosure data of the ATV630U07N4
Rated motor power: 0.75 kW normal duty; 0.37 kW heavy duty. Nominal output current: 2.2 A. Supply voltage: 380 to 480 V. Network frequency: 50-60 Hz. Supply frequency: 50 to 60 Hz (tolerance -5 % / +5 %). Motor power ratings: 0.75 kW normal duty; 0.37 kW heavy duty. Discrete inputs: 8. Discrete outputs: 0. Analogue inputs: 3. Analogue outputs: 2. Analogue input types: AI1, AI2, AI3 software-configurable voltage 0 to 10 V DC 31.5 kOhm 12 bits. Output type: Relay outputs R1A, R1B, R1C 250 V AC 3000 mA; Relay outputs R1A, R1B, R1C 30 V DC 3000 mA; Relay outputs R2A, R2C 250 V AC 5000 mA. Communication protocols: Modbus TCP; Ethernet; Modbus serial. Output voltage: <= power supply voltage.
Process drives are judged by how they behave in a plant system, not only by the motor they turn. The ATV630 range is aimed at integration with a plant network, with a built-in Ethernet option as a common choice, and it carries functions such as multi-pump handling and flow estimation without a flow meter.
Place of the ATV630U07N4 among the Altivar Process range
The ATV630 is the standard wall or floor version of the Altivar Process line; the ATV650 is the 6-pulse and 12-pulse family of the same generation with a different mechanical design, and the ATV930 is the heavier Altivar Process variant for demanding loads. For small motors up to a few kW the ATV630U07N4 and its neighbours U15N4 and U22N4 are the usual choices.
Parameter migration between sizes is straightforward, because the same menu structure and the same graphic terminal are used throughout the family. Keep the configuration file of each installed drive in the maintenance records so a spare can be loaded in minutes.
Selection checklist for the ATV630U07N4
- Motor nameplate power and current: 0.75 kW and the motor rated current.
- Mains: three phase 380 to 480 V and available short-circuit level.
- Network: fieldbus type needed and whether an option module is required.
- Environment: IP21 enclosure suits indoor, clean electrical rooms only.
- Process features needed: PID, pump cascade, sleep mode, safe torque off.
- Motor cable length and the need for an output filter.
Installation and set-up of the ATV630U07N4
Mount the drive vertically on a flat panel with the airflow clearances of the installation manual and keep a clean separation between the motor cable and control wiring. Screen the motor cable and bond the screen at both ends.
At first start, enter the motor data, run the auto-tune with the motor uncoupled if possible, and set the macro configuration that best matches the process. Record minimum and maximum frequency, ramps and the PID settings.
Typical applications of the ATV630U07N4 in Oman and the GCC
In Oman and the GCC the ATV630 class is used on chemical dosing and small cooling-water pumps, sump and transfer pumps in water treatment, and fans in utility rooms. Ambient heat in electrical rooms in summer calls for a check of derating and a clean cabinet filter.
Dimensions, environment and approvals of the ATV630U07N4
For the ATV630U07N4, plan the mounting space from the datasheet: 144 mm (W) x 350 mm (H) x 203 mm (D). The ATV630U07N4 weighs 4.5 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -15 to 50 °C (without derating). Relative humidity: 5 to 95 % without condensation IEC 60068-2-3. Ingress protection: IP21 IEC 61800-5-1; IP21 IEC 60529. Operating altitude: <= 1000 m without derating; 1000 to 4800 m with current derating 1 % per 100 m. Vibration resistance: 1.5 mm peak to peak (f= 2 to 13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13 to 200 Hz) conforming to IEC 60068-2-6. Shock resistance: 15 gn 11 ms IEC 60068-2-27. Standards listed: UL 508C; IEC 61800-3; IEC 61800-3 environment 1 category C2; EN/IEC 61800-3 environment 2 category C3; IEC 61800-5-1; IEC 61000-3-12. Certifications listed for this reference: TÜV; ATEX zone 2/22; CSA; DNV-GL; UL; ATEX INERIS.
Information to send with an RFQ for the ATV630U07N4
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Atv630 Range
Seven Star LLC supplies models from the Se Atv630 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric ATV630D75N4 75 kW Process Drive | AC Drives | View details |
| Schneider Electric ATV630D22N4 22 kW Process Drive | AC Drives | View details |
| Schneider Electric ATV630U30N4 3 kW Process Drive IP21 | AC Drives | View details |
| Schneider Electric ATV630U07N4 Altivar Process 0.75 kW Drive | AC Drives | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric ATV630U07N4 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric ATV630U07N4 Altivar Process 0.75
Answers from our engineering team on installation, compatibility and integration.
01What power rating is the ATV630U07N4?
The datasheet lists 0.75 kW normal duty; 0.37 kW heavy duty.
02What supply voltage does the ATV630U07N4 use?
Stated as 380 to 480 V.
03Which communication ports does the ATV630U07N4 list?
The datasheet gives Modbus TCP; Ethernet; Modbus serial.
04What is the net weight of the ATV630U07N4?
The datasheet gives 4.5 kg.
05What ingress protection does the ATV630U07N4 list?
Stated as IP21 IEC 61800-5-1; IP21 IEC 60529.


















Reviews