Brand:

MTL MTL5042 Repeater Power Supply for 2- or 3-Wire Transmitters

Description

MTL5042 overview

The MTL5042 is a single-channel repeater power supply in the MTL5000 Series. It provides a fully floating dc supply for a conventional 2-wire or 3-wire 4-20 mA transmitter installed in a hazardous area and repeats the transmitter current in a second floating circuit to drive a safe-area load. For smart 2-wire transmitters, the MTL5042 allows bidirectional communication signals to be superimposed on the 4-20 mA signal, so a handheld communicator can be used from the safe side.

What distinguishes the MTL5042 is its protocol coverage. The datasheet lists HART, Honeywell DE, Foxboro and Yokogawa Brain communications, which makes the unit useful on plants that run mixed generations of instrumentation. Galvanic isolation between supply, input and output means no separate intrinsic safety earth is needed for the isolator, and removable plugs let a module be replaced without rewiring. The datasheet for the MTL5042 is dated August 2008.

Key features of the MTL MTL5042

  • Powers 2-wire or 3-wire 4-20 mA transmitters from a floating supply
  • One channel with a repeated 4-20 mA output able to drive loads from 0 to 600 ohm
  • Communication support for HART, Honeywell DE, Foxboro and Yokogawa Brain
  • Optional handheld communicator connections on both hazardous-area and safe-area sides
  • Transfer accuracy better than 10 microamperes at 20 degrees C
  • Fast response, settling within 10 percent of final value within 40 microseconds, with a digital bandwidth of 10 Hz to 12 kHz
  • Supply 20 to 35 V dc and a green power LED
  • Transmitter location in Zone 0 (IIC, T4 to T6, if suitably certified) or Division 1 Group A

MTL5042 technical specifications

The table summarises the MTL5042 datasheet. Confirm against the certification printed on the module supplied.

Parameter Value
Model MTL5042 repeater power supply, 4/20 mA smart, for 2- or 3-wire transmitters
Channels One
Transmitter location Zone 0, IIC, T4-6 if suitably certified; Div. 1, Group A
Supply voltage 20 to 35 V dc
Maximum current consumption (20 mA signal) 75 mA at 24 V; 85 mA at 20 V; 55 mA at 35 V
Maximum power dissipation (20 mA signal) 1.3 W at 24 V
Output signal range 4 to 20 mA; under/over-range 0 to 24 mA
Safe-area load resistance 0 to 600 ohm
Output resistance Greater than 2 Mohm
Output ripple Less than 40 microamperes peak-to-peak
Input signal range 0 to 24 mA including over-range
Transmitter voltage 16.5 V at 20 mA
Transfer accuracy at 20 C Better than 10 microamperes
Temperature drift Less than 0.5 microamperes per degree C
Response time Settles within 10 percent of final value within 40 microseconds
Digital signal bandwidth 10 Hz to 12 kHz
Communications supported HART, Honeywell DE, Foxboro, Yokogawa Brain
Safety description, terminals 2 to 1 and 3 28 V, 300 ohm, 93 mA; Um 250 V rms or dc
Safety description, terminals 1 to 3 Non-energy-storing apparatus: 1.2 V, 0.1 A, 20 microjoules, 25 mW
Terminals 1 current input, 2 transmitter supply +ve, 3 common, 11 output -ve, 12 output +ve, 13 supply -ve, 14 supply +ve
Mounting 35 mm top-hat DIN rail, plug-in terminals (MTL5000 Series)
Ambient limits (MTL5000 Series, unenclosed, close-packed) -20 to +60 degrees C

Terminals 4 to 6 and 7 to 9 can accept the optional HAZ4-6 and SAF7-9 connectors for handheld communicator access. The datasheet adds that terminals 1 and 3 support HART communication in only one direction, from the field device to the safe-area connections 11 and 12.

Typical applications in oil and gas, utilities, water and manufacturing

The MTL5042 is a general-purpose interface for loops that start in a classified area and end in a control room or marshalling cabinet. In Oman’s oil and gas sector it serves smart pressure, temperature and flow transmitters on wellheads, pipelines and process skids, passing the 4-20 mA signal and HART data to the DCS. The ability to power both 2-wire and 3-wire devices from the same module type helps standardise spares at remote sites.

Utilities and water companies in the GCC use the MTL5042 for level and analytical transmitters in sewage pumping, biogas and fuel-storage areas. Industrial plants that still run older Honeywell DE, Foxboro or Yokogawa Brain transmitters value the protocol support, because it allows an existing interface to be matched without re-engineering the loop.

Selection and compatibility notes for MTL5042

Choose the MTL5042 for a single transmitter and a single safe-area receiver. If you need two receivers on one smart 2-wire transmitter, the MTL5043 offers two outputs, while the MTL5041 and MTL5045 variants in the same range suit other loop arrangements. Check that the transmitter works with the 16.5 V available at 20 mA and that the receiver does not exceed 600 ohm in total with the wiring.

Compare the MTL5042 safety description of 28 V, 300 ohm and 93 mA with the field device entity parameters and cable capacitance and inductance, and verify the supply of 20 to 35 V dc. For 3-wire transmitters, note how terminals 1, 2 and 3 are used in the datasheet wiring diagram, since the common terminal 3 differs from a 2-wire connection.

Installation and commissioning

Before mounting the MTL5042, confirm the hazardous-area apparatus and the cable parameters against the entity values on the nameplate and in the manufacturer certificate, and decide where the intrinsic safety earth will be taken. Mount the unit on the 35 mm top-hat DIN rail in a clean enclosure or cabinet in the safe area, keeping hazardous-area and safe-area wiring physically separated and clearly labelled. MTL5000 Series modules clip onto T35 rail with a maximum mounting pitch of 16.2 mm, and the supply terminals 13 and 14 can be linked through a power bus kit. Use the HAZ4-6 and SAF7-9 connectors only if handheld communicator access is required.

Wire the MTL5042 strictly to the terminal table in the datasheet, tighten the terminal screws to the specified torque and check that no strands are left outside the clamp. Where the unit carries a certificate, the earth connection and the rail must meet the requirements stated there. After wiring, apply the supply, check the power indication, and simulate the field signal to prove the end-to-end loop before the plant is declared ready. Record the as-found readings for future loop checks of the MTL5042.

Maintenance and service life

The MTL5042 has no user-serviceable parts, so maintenance is mainly periodic inspection. During planned shutdowns, inspect terminals for corrosion and looseness, verify the supply voltage at the unit, and repeat the loop check recorded at commissioning. In coastal or humid locations around Muscat, Sohar and Duqm, a sealed or purged cabinet with a clean, dry interior greatly extends the life of any electronic interface such as the MTL5042.

If a loop drifts outside its tolerance or the unit shows no power indication with a healthy supply, replace the module rather than attempting repair, and keep the replacement documentation with the loop folder. Because certified intrinsically safe equipment must not be modified, any change in cabling, load or hazardous-area device should be re-assessed against the MTL5042 entity parameters before it is put into service.

Related products and ordering notes

Customers who enquire about the MTL5042 often also need matching accessories and neighbouring models from the same family, such as the MTL5043 dual-output repeater power supply, the MTL5041 and MTL5045 repeater power supplies, power bus kits and the MTL5099 dummy isolator. For 3-wire applications, please tell us the transmitter model so we can check the wiring.

When you send an enquiry for the MTL5042, please quote the full part number exactly as printed on the nameplate, the quantity, and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the MTL5042 you need. Our team can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about MTL5042

The MTL5042 is a single-channel repeater power supply for 2- or 3-wire 4-20 mA transmitters, with a 600 ohm load capability, 16.5 V transmitter voltage, 10 microampere accuracy and support for HART, Honeywell DE, Foxboro and Yokogawa Brain. It uses 20 to 35 V dc and mounts on DIN rail.

Documents and quotation

A copy of the datasheet for the MTL5042 is available on this page for your engineering review. To request a quotation, send the RFQ with the part number MTL5042, the quantity, the delivery location and any certification or documentation requirements, and we will respond with availability and lead time. Please review the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with MTL. Product names and part numbers are used only to identify the item you ask for.

Other Models in the MTL5000 Range

Seven Star LLC supplies models from the MTL5000 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MTL MTL5043 Dual-Output 4-20 mA Repeater Power SupplyIsolator & BarrierView details
MTL MTL5042 Repeater Power Supply for 2- or 3-Wire TransmittersIsolator & BarrierYou are viewing this model
Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL MTL5042 Repeater Power Supply for 2- or 3-Wire

Answers from our engineering team on installation, compatibility and integration.

01Which transmitters can the MTL5042 power?
The datasheet states that the MTL5042 energises a conventional 2-wire or 3-wire 4-20 mA transmitter located in a hazardous area.
02Which communication protocols does the MTL5042 support?
The datasheet lists HART, Honeywell DE, Foxboro and Yokogawa Brain communications on the 4-20 mA signal.
03What is the supply and current of the MTL5042?
It needs 20 to 35 V dc and draws 75 mA at 24 V with a 20 mA signal, dissipating up to 1.3 W at 24 V.
04What are the MTL5042 safety parameters?
Terminals 2 to 1 and 3 are 28 V, 300 ohm and 93 mA with Um 250 V rms or dc, as listed in the datasheet.
05How can I order the MTL5042?
Send an RFQ quoting MTL5042 with the quantity and delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.