Brand:

MTL MTL5043 Dual-Output 4-20 mA Repeater Power Supply

Description

MTL5043 overview

The MTL5043 is a repeater power supply from the MTL intrinsic safety range. It provides a fully floating dc supply that energises a conventional 2-wire 4-20 mA smart transmitter installed in a hazardous area, and it repeats the transmitter current into two separate floating circuits so that two safe-area loads can be driven from a single field device. HART communication is repeated through channel 1 only, which keeps bidirectional communication available for a handheld communicator or an asset-management system while channel 2 serves a second receiver.

The MTL5043 belongs to the slim MTL5000 Series of DIN-rail isolators. Signal and power connections are made through removable plug-in terminals, so a module can be exchanged without disturbing the field wiring. Because the unit is galvanically isolated between supply, input and outputs, no intrinsic safety earth is needed for the isolator itself, which simplifies cabinet design compared with shunt-diode barriers. The datasheet for the MTL5043 is dated August 2008 and describes the unit as a single-channel input with two outputs.

Key features of the MTL MTL5043

  • One hazardous-area input with two isolated safe-area outputs, each carrying 4-20 mA with a 0-24 mA over and under range
  • Powers a 2-wire smart transmitter with 15.5 V available at 20 mA
  • HART repeated on channel 1, with a 220 ohm series resistor in the channel 1 output path for HART applications
  • Channel 2 can be wired as an active current source or as a passive current sink, according to the receiving device
  • Transfer accuracy better than 20 microamperes at 20 degrees C, typically under 5 microamperes
  • 250 V ac or dc isolation between power supply, input and outputs
  • Green LED for power indication and a 20 to 35 V dc supply compatible with common 24 V dc cabinet supplies
  • Transmitter may be located in Zone 0 (IIC, T4 to T6, if suitably certified) or Division 1 Group A

MTL5043 technical specifications

The values below are taken from the MTL5043 datasheet. Always confirm against the certificate marked on the module you receive.

Parameter Value
Model MTL5043 repeater power supply, dual output, 4/20 mA, for 2-wire smart transmitters
Channels One input, two outputs
Transmitter location Zone 0, IIC, T4-6 if suitably certified; Div. 1, Group A
Supply voltage 20 to 35 V dc
Maximum current consumption (two 20 mA signals) 100 mA at 24 V; 120 mA at 20 V; 80 mA at 35 V
Maximum power dissipation (two 20 mA signals) 1.7 W at 24 V
Isolation 250 V ac or dc between supply, input and outputs
Input signal range 0 to 24 mA including over-range
Transmitter voltage 15.5 V at 20 mA
Output signal range 4 to 20 mA; over/under-range 0 to 24 mA
Channel 1 load 0 to 350 ohm (terminals 11 and 12); 0 to 130 ohm (terminals 10 and 11)
Channel 2 load 0 to 550 ohm; current-sink mode 1 kohm, maximum 30 V
Output resistance Greater than 2 Mohm
Output ripple Less than 125 microamperes peak-to-peak
Transfer accuracy at 20 C Better than 20 microamperes (typically under 5 microamperes)
Temperature drift Less than 0.5 microamperes per degree C
Response time Both outputs settle to within 10 percent of final value in 500 microseconds
Digital signal bandwidth 400 Hz to 4 kHz
Communication supported HART
Safety description Uo 28 V, Io 93 mA, Po 0.65 W, Um 253 V rms
Indicator Green LED, power
Mounting 35 mm top-hat DIN rail, plug-in terminals (MTL5000 Series)
Ambient limits (MTL5000 Series, unenclosed, close-packed) -20 to +60 degrees C

The datasheet carries an important note: MTL5043 units marked Baseefa 03ATEX0584 pass HART and meet the full specification, whereas modules carrying the BAS01ATEX7154 or Ex97D2248 certification do not pass HART and are not fitted with the channel 2 current-sink output on terminal 7 or the 220 ohm series resistor on terminal 10. If your loops use HART, check the certificate marking when you compare the MTL5043 you are replacing with the one you order.

Typical applications in oil and gas, utilities, water and manufacturing

A repeater power supply such as the MTL5043 is used wherever a 4-20 mA transmitter in a classified area must feed more than one receiver. In oil and gas facilities in Oman, a typical case is a pressure or level transmitter on a separator whose signal goes to both the distributed control system and an independent shutdown or monitoring system. The two isolated outputs of the MTL5043 keep those two systems electrically separate, so a fault or maintenance activity on one receiver does not disturb the other.

In water and wastewater plants, utilities and desalination sites across the GCC, the MTL5043 is suitable for smart transmitters on chemical dosing, biogas and sludge-handling duties where a hazardous zone exists. In manufacturing and petrochemical units it supports legacy loops where a dual-output repeater was originally specified. Because HART is passed on channel 1, the unit also suits plants that rely on handheld communicators or asset-management software for transmitter configuration and diagnostics.

Selection and compatibility notes for MTL5043

Select the MTL5043 when you have one 2-wire transmitter and need two safe-area outputs. If you only need a single output and may also have 3-wire transmitters, the single-output MTL5042 from the same range is the usual alternative. Check that the transmitter operates with 15.5 V at 20 mA available, and that the combined loop resistance on each channel stays inside the load ranges in the table, bearing in mind the 220 ohm series resistor in the HART path of channel 1.

Confirm the entity parameters of the transmitter and cable against the MTL5043 safety description of Uo 28 V, Io 93 mA and Po 0.65 W, and the zone, gas group and temperature class of the installation. Check the supply: the unit requires 20 to 35 V dc and draws up to 120 mA at 20 V with two 20 mA signals, so size the cabinet supply and power bus accordingly.

Installation and commissioning

Before mounting the MTL5043, confirm the hazardous-area apparatus and the cable parameters against the entity values on the nameplate and in the manufacturer certificate, and decide where the intrinsic safety earth will be taken. Mount the unit on the 35 mm top-hat DIN rail in a clean enclosure or cabinet in the safe area, keeping hazardous-area and safe-area wiring physically separated and clearly labelled. The MTL5000 Series modules clip onto low-profile or high-profile T35 rail with a maximum mounting pitch of 16.2 mm per unit, and the removable plugs carry the signal and power connections; a power bus kit can link the supply terminals 13 and 14 of up to 32 modules.

Wire the MTL5043 strictly to the terminal table in the datasheet, tighten the terminal screws to the specified torque and check that no strands are left outside the clamp. Where the unit carries a certificate, the earth connection and the rail must meet the requirements stated there. After wiring, apply the supply, check the power indication, and simulate the field signal to prove the end-to-end loop before the plant is declared ready. Record the as-found readings for future loop checks of the MTL5043.

Maintenance and service life

The MTL5043 has no user-serviceable parts, so maintenance is mainly periodic inspection. During planned shutdowns, inspect terminals for corrosion and looseness, verify the supply voltage at the unit, and repeat the loop check recorded at commissioning. In coastal or humid locations around Muscat, Sohar and Duqm, a sealed or purged cabinet with a clean, dry interior greatly extends the life of any electronic interface such as the MTL5043.

If a loop drifts outside its tolerance or the unit shows no power indication with a healthy supply, replace the module rather than attempting repair, and keep the replacement documentation with the loop folder. Because certified intrinsically safe equipment must not be modified, any change in cabling, load or hazardous-area device should be re-assessed against the MTL5043 entity parameters before it is put into service.

Related products and ordering notes

Customers who enquire about the MTL5043 often also need matching accessories and neighbouring models from the same family, such as the MTL5042 single-output repeater power supply, the MTL5044 two-channel repeater power supply, power bus kits and the MTL5099 dummy isolator for terminating unused cores. Where the MTL5043 is being replaced in an existing loop, confirm the HART behaviour described in the datasheet note before ordering.

When you send an enquiry for the MTL5043, please quote the full part number exactly as printed on the nameplate, the quantity, and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the MTL5043 you need. Our team can arrange a quotation with delivery to Oman and across the GCC.

Frequently asked questions about MTL5043

In short, the MTL5043 is a dual-output HART-capable repeater power supply for one 2-wire smart transmitter. It runs from 20 to 35 V dc, isolates supply, input and outputs at 250 V, carries safety parameters of 28 V, 93 mA and 0.65 W, and offers 4-20 mA on both outputs with HART on channel 1 only. Check the certificate variant if HART is needed.

Documents and quotation

A copy of the datasheet for the MTL5043 is available on this page for your engineering review. To request a quotation, send the RFQ with the part number MTL5043, the quantity, the delivery location and any certification or documentation requirements, and we will respond with availability and lead time. Please review the specification against your loop or system requirements before ordering.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with MTL. Product names and part numbers are used only to identify the item you ask for.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MTL is a British maker of intrinsic safety interfaces, surge protection and hazardous-area equipment, founded in 1971 in Luton as Measurement Technology Ltd, a spin-off from Kent Instrumentation. In 2008 Cooper Industries bought MTL Instruments for £144 million and placed it in its Crouse-Hinds division; Eaton acquired Cooper in 2012. MTL is now part of Eaton's Crouse-Hinds business, alongside the MEDC signalling range.

Seven Star LLC lists MTL isolators, a fieldbus barrier and the configuration tools for them, and supplies MTL (Eaton) barriers and spare modules to sites in Oman as an independent supplier.

MTL (Eaton) company profile

Founded 1971, Luton, England, as Measurement Technology Ltd
Origin Spin-off from Kent Instrumentation
Headquarters Luton, England
Ownership Eaton (Crouse-Hinds), via Cooper Industries from 2008
Product families MTL5500 and MTL4500 isolators, MTL7700 zener barriers, 9300 fieldbus barriers, surge protection devices, process junction boxes, PCS45 configuration software; MEDC beacons, sounders and call points

Milestones

  • 1971: Measurement Technology Ltd is founded in Luton.
  • 2007: MTL acquires ELPRO Technologies, RTK Instruments and Ocean Technical Systems.
  • 2008: Cooper Industries acquires MTL Instruments for £144 million.
  • 2012: Eaton acquires Cooper Industries.

MTL product families listed here

Most of the listed items are DIN-rail galvanic isolators. The MTL5541 repeater power supply and the MTL5576-THC temperature converter belong to the MTL5500 range, and the MTL 5043 repeater power supply comes from the earlier MTL5000 range that many plants still run. The MTL 9370-FB2 is a fieldbus barrier for intrinsically safe FOUNDATION fieldbus spurs. PCS45 software with the PCL45USB link is the configurator for MTL converter modules. For the listed part CPM08-BN, please send a label photo so the number can be matched to the manufacturer's records. Newer labels show Eaton MTL, older ones Measurement Technology Ltd, and the module numbers are the same. The MTL 9608 is a fieldbus junction box with eight spur outlets plus a trunk-in connection, listed under the Crouse-Hinds series part number FCS-9608.

Where MTL barriers and isolators are used

These interfaces sit in marshalling cabinets wherever instruments are located in Zone 0, 1 or 2 areas: gas plants, refineries, offshore platforms, tank farms and chemical units across the GCC. They power 2-wire transmitters, pass HART, convert thermocouple signals and drive solenoids or alarms while limiting energy to the field circuit.

MTL (Eaton) products we list

Family Examples
Isolator & Barrier Eaton MTL5541 Repeater Power Supply, MTL 5043, MTL 9370-FB2 Intrinsically Safe Fieldbus…, MTL CPM08-BN, MTL5576-THC Temperature Isolator Module
Automation Accessories MTL 9608 Process Junction Box
Automation Software MTL PCS45 Configuration Software and PCL…

Ordering MTL modules: what we need

Send the full module number including every suffix, for example MTL5576-THC and not just MTL5576, and the quantity. Tell us if the module mounts on DIN rail or on a backplane, because MTL5500 and MTL4500 parts are not interchangeable. For a fieldbus barrier give the number of spurs and the enclosure reference. A photo of the side label, which shows the certificate numbers, helps when the certificate for your project file must match.

Facts checked against the Eaton MTL company history and Drives & Controls coverage of the 2008 Cooper offer, October 2026.

FAQ

Questions about the MTL MTL5043 Dual-Output 4-20 mA Repeater Power

Answers from our engineering team on installation, compatibility and integration.

01What does the MTL5043 do?
The MTL5043 powers a 2-wire smart 4-20 mA transmitter in a hazardous area and repeats its current to two isolated safe-area outputs, with HART passed on channel 1.
02What supply voltage does the MTL5043 need?
The datasheet specifies 20 to 35 V dc, with up to 100 mA at 24 V when both outputs carry 20 mA, and 1.7 W maximum dissipation at 24 V.
03Does the MTL5043 pass HART on both channels?
HART is repeated through channel 1 only. Also note that certificate variants BAS01ATEX7154 and Ex97D2248 do not pass HART according to the datasheet.
04What are the safety parameters of the MTL5043?
The datasheet gives Uo 28 V, Io 93 mA, Po 0.65 W and Um 253 V rms for the hazardous-area circuit.
05How do I order the MTL5043 from Seven Star LLC?
Send an RFQ quoting MTL5043, the quantity and your delivery location in Oman or the GCC, and we will reply with availability and lead time.