Brand: Moore Industries
SPA2IS/TPRG/2PRG/U/-AO [DIN] IS Limit Alarm Trip
Description
Moore SPA2IS/TPRG/2PRG/U/-AO [DIN] overview
The Moore SPA2IS/TPRG/2PRG/U/-AO [DIN] is a programmable limit alarm trip with intrinsically safe field connections. According to the manufacturer, it accepts signals from transmitters and temperature sensors located in hazardous areas where intrinsic safety is the method of protection, and it does this without a separate intrinsically safe barrier, because the field connections provide the necessary protection typically afforded by a galvanically isolated barrier.
This model accepts temperature inputs: the datasheet lists 23 RTD types, 9 thermocouple types, resistance and potentiometer devices and direct millivolt sources. Two independent relay outputs are used to activate a warning light, annunciator, pump, motor or shutdown system.
The part number SPA2IS/TPRG/2PRG/U/-AO [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, power, options and housing (Unit / Input / Output / Power / Options [Housing]). The string written as SPA2IS/TPRG/2PRG/U/-AO [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.
- SPA2IS: programmable limit alarm trip with intrinsically safe field connections
- TPRG: programmable temperature input
- 2PRG: two programmable relays
- U: universal power input
- -AO: isolated analog output option
- [DIN]: DIN-style housing
Key features of the Moore Industries SPA2IS/TPRG/2PRG/U/-AO [DIN]
- Intrinsically safe field connections that remove the need for an additional isolating barrier on the field side.
- Accepts 23 RTD types, 9 thermocouple types, resistance, potentiometer and millivolt inputs.
- Two independent, individually configurable alarm relays (quad relay models also exist).
- Alarm trip delay programmable from 0 to 120 seconds.
- Optional isolated analog output.
- Line-powered with universal supply.
Technical specifications for SPA2IS/TPRG/2PRG/U/-AO [DIN]
| Parameter | Value |
|---|---|
| Model string | Moore SPA2IS/TPRG/2PRG/U/-AO [DIN] |
| Relay outputs | SPDT relays, 1 form C, 5 A at 250 Vac 50/60 Hz or 24 Vdc, non-inductive |
| Trip response time | 256 ms typical, measured from input step to alarm state change |
| Alarm trip delay | 0 to 120 seconds programmable |
| Analog output response | 256 ms maximum for a 10% to 90% change |
| Analog output accuracy (-AO) | plus or minus 0.01% of maximum span |
| Isolation | 500 Vrms between case, input, output and power, continuous |
| Dielectric strength | 1560 Vrms for 2 seconds between input, output and power; 500 Vrms for 2 seconds from case to input, output or power |
| Power supply effect | plus or minus 0.002% of span per 1% line voltage change |
The values above come from the manufacturer datasheet for the SPA2IS family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.
Typical applications of the SPA2IS/TPRG/2PRG/U/-AO [DIN] in Oman and the GCC
The unit is aimed at temperature points in hazardous areas, for example in Zone 0, 1 or Class I Division 1 and 2 locations as shown on the datasheet figure, such as storage tanks, process vessels and pump skids in refineries and gas plants.
In oil and gas facilities across Oman and the GCC, a programmable alarm trip such as the SPA2IS/TPRG/2PRG/U/-AO [DIN] is used as a stand-alone high or low limit device on temperature, pressure, level and flow signals. It can drive a shutdown relay, a horn or beacon, or a lamp on a local annunciator without loading the main control system.
Power utilities and desalination and water plants use alarm trips to protect motors, pumps and heat exchangers: for example a winding or bearing temperature limit, a tank level limit, or a discharge pressure limit that must act even when the DCS is offline. Manufacturing and process plants use the same idea for batch limits, furnace over-temperature cut-outs and dosing interlocks.
Because the SPA2IS/TPRG/2PRG/U/-AO [DIN] sets up from its front panel or from PC software, one unit stocked in the store room can cover many different duties, which is helpful for remote sites where spare lead times matter.
Selection and compatibility notes for SPA2IS/TPRG/2PRG/U/-AO [DIN]
Hazardous-area suitability depends on the certificate and the entity parameters of the specific model. Always check the certificate documents of the manufacturer against your area classification and your wiring design before installation.
Confirm the input type first. The SPA2IS family has different model strings for current and voltage inputs and for temperature and resistance inputs, so the input field of the part number must match the sensor or transmitter you are wiring.
Check the relay contact rating against the load you intend to switch. The relays are rated for the values shown in the specifications table; for inductive loads such as contactor coils or solenoids, use an interposing relay or suppression as your plant standard requires.
Decide whether the unit is a replacement or a new installation. For replacements, compare the supply range, relay count, analog output option and housing against the nameplate of the unit being removed. Send the old nameplate details together with your RFQ and we will compare them with the datasheet ordering table.
Installation and commissioning
Mount the SPA2IS/TPRG/2PRG/U/-AO [DIN] on its rail or bracket in a clean, ventilated panel, away from heavy switchgear and power cables where possible. Leave room for the front-panel buttons and for the viewing angle of the display.
Wire the supply, input and relay terminals according to the terminal drawing in the manufacturer manual. Use the wire size range given in that manual and tighten terminals to the stated torque. Keep the input cable separate from relay and power cabling and use shielded cable on long sensor or signal runs.
On power-up, set the input type and range, assign each relay to a high or low trip with its trip point and dead band, choose normally open or closed and failsafe behaviour, and set any trip delay. Test every relay by moving the input signal through the trip point, and record the final settings and password in your commissioning file.
Maintenance and spares
Alarm trips are low-maintenance devices, but a safety or shutdown duty deserves a documented proof-test. Plan a periodic functional check of each relay by simulating the input at and beyond the trip points, and verify that the downstream shutdown or alarm action really occurs.
Check terminals for tightness and corrosion during planned outages, keep the front window and vents free of dust, and record the as-found and as-left settings. If a unit is replaced, load the saved configuration or re-enter the recorded settings and repeat the functional test before returning the loop to service.
Related products and ordering notes
Non-IS versions are the SPA2 range. For HART loops, see the SPA HART alarm. The datasheet is available on request.
Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Frequently asked questions about SPA2IS/TPRG/2PRG/U/-AO [DIN]
- What is special about the SPA2IS/TPRG/2PRG/U/-AO [DIN]? It has intrinsically safe field connections, so signals from hazardous areas can be connected without a separate isolated barrier.
- Which inputs does the SPA2IS/TPRG/2PRG/U/-AO [DIN] accept? The datasheet lists 23 RTD types, 9 thermocouple types, resistance and potentiometer devices, and millivolt sources.
- How many relays does the SPA2IS/TPRG/2PRG/U/-AO [DIN] have? The 2PRG output gives two independent, individually configurable relays.
- What isolation does the SPA2IS/TPRG/2PRG/U/-AO [DIN] have? The datasheet states 500 Vrms continuous isolation between case, input, output and power.
- How do I ask for a quotation for the SPA2IS/TPRG/2PRG/U/-AO [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.
Documents and quotation
The manufacturer datasheet for the SPA2IS family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.
To request a quotation, send an RFQ that includes the part number SPA2IS/TPRG/2PRG/U/-AO [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.
Datasheets & Documents
- Datasheet SPA2IS Alarm Trip with Intrinsically Safe Field Connections Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the SPA2IS/TPRG/2PRG/U/-AO [DIN] IS Limit Alarm Trip
Answers from our engineering team on installation, compatibility and integration.
01What is special about the SPA2IS/TPRG/2PRG/U/-AO [DIN]?
It has intrinsically safe field connections, so signals from hazardous areas can be connected without a separate isolated barrier.
02Which inputs does the SPA2IS/TPRG/2PRG/U/-AO [DIN] accept?
The datasheet lists 23 RTD types, 9 thermocouple types, resistance and potentiometer devices, and millivolt sources.
03How many relays does the SPA2IS/TPRG/2PRG/U/-AO [DIN] have?
The 2PRG output gives two independent, individually configurable relays.
04What isolation does the SPA2IS/TPRG/2PRG/U/-AO [DIN] have?
The datasheet states 500 Vrms continuous isolation between case, input, output and power.
05How do I ask for a quotation for the SPA2IS/TPRG/2PRG/U/-AO [DIN]?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.

















![SPA2IS/TPRG/2PRG/U/-AO [DIN] IS Limit Alarm Trip SPA2IS/TPRG/2PRG/U/-AO [DIN] IS Limit Alarm Trip](https://omansevenstar.com/wp-content/uploads/2026/11/moore-industries-spa2is-tprg-2prg-u-ao-din-is-limit-alarm-trip.webp)
Reviews