SPA2/TPRG/2PRG/U/-AO [DIN] Limit Alarm Trip
Description
Moore SPA2/TPRG/2PRG/U/-AO [DIN] overview
The Moore SPA2/TPRG/2PRG/U/-AO [DIN] is a line-powered, site-programmable limit alarm trip from the Moore Industries SPA2 family. In this configuration it takes a temperature input, which can be an RTD, a thermocouple, a millivolt source or a resistance, and operates two independent relays.
Each relay is configured for high or low trip, normally open or closed, failsafe or non-failsafe and latching or non-latching operation. The -AO option adds an isolated, linearised analog output, so the unit works as an alarm trip and a signal transmitter at the same time.
Settings are made through the front-panel buttons or with the Intelligent PC Configuration Software.
The part number SPA2/TPRG/2PRG/U/-AO [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, power, options and housing (Unit / Input / Output / Power / Options [Housing]). The string written as SPA2/TPRG/2PRG/U/-AO [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.
- SPA2: site-programmable limit alarm trip
- TPRG: programmable temperature input: RTD, thermocouple, millivolt, ohms
- 2PRG: two programmable SPDT relays
- U: universal power input, 21.6 to 375 Vdc or 90 to 260 Vac
- -AO: isolated analog output option
- [DIN]: DIN-style housing for 35 mm Top Hat rail
Key features of the Moore Industries SPA2/TPRG/2PRG/U/-AO [DIN]
- Two SPDT relays, each individually configurable for high or low trip, NO or NC, failsafe or non-failsafe, latching or non-latching.
- Direct RTD (2-, 3- and 4-wire; platinum, copper, nickel) and thermocouple inputs.
- Alarm trip delay programmable from 0 to 120 seconds.
- Optional isolated analog output with user-set failure limits for upscale, downscale or last-value drive.
- Universal power supply accepting 21.6 to 375 Vdc or 90 to 260 Vac.
- Operates from -40 to +85 degrees C.
Technical specifications for SPA2/TPRG/2PRG/U/-AO [DIN]
| Parameter | Value |
|---|---|
| Model string | Moore SPA2/TPRG/2PRG/U/-AO [DIN] |
| Relay outputs (2PRG) | Two SPDT relays, 1 form C, 5 A at 250 Vac 50/60 Hz or 24 Vdc, non-inductive |
| Analog output (-AO) | Isolated and linearised, 0 to 20 mA into 1000 ohms or 0 to 10 V into 10 kohms; accuracy plus or minus 0.01% of maximum span |
| Trip response time | 256 ms maximum |
| Alarm trip delay | 0 to 120 seconds programmable |
| Power supply | Universal 21.6 to 375 Vdc or 90 to 260 Vac |
| Isolation | 500 Vrms between case, input, output and power |
| Dielectric strength | 1966 Vdc for 2 seconds |
| Power supply effect | plus or minus 0.002% of span per 1% line voltage change |
| Operating temperature | -40 to +85 degrees C (-40 to +185 degrees F) |
| Storage temperature | -40 to +85 degrees C |
| Relative humidity | 0 to 95%, non-condensing |
| Temperature effect on output | plus or minus 0.009% of maximum span per degree C |
The values above come from the manufacturer datasheet for the SPA2 family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.
Typical applications of the SPA2/TPRG/2PRG/U/-AO [DIN] in Oman and the GCC
Typical duties are high winding temperature trips on motors and generators, high bearing temperature trips on pumps and compressors and over-temperature protection on process heaters.
In oil and gas facilities across Oman and the GCC, a programmable alarm trip such as the SPA2/TPRG/2PRG/U/-AO [DIN] is used as a stand-alone high or low limit device on temperature, pressure, level and flow signals. It can drive a shutdown relay, a horn or beacon, or a lamp on a local annunciator without loading the main control system.
Power utilities and desalination and water plants use alarm trips to protect motors, pumps and heat exchangers: for example a winding or bearing temperature limit, a tank level limit, or a discharge pressure limit that must act even when the DCS is offline. Manufacturing and process plants use the same idea for batch limits, furnace over-temperature cut-outs and dosing interlocks.
Because the SPA2/TPRG/2PRG/U/-AO [DIN] sets up from its front panel or from PC software, one unit stocked in the store room can cover many different duties, which is helpful for remote sites where spare lead times matter.
Selection and compatibility notes for SPA2/TPRG/2PRG/U/-AO [DIN]
The datasheet offers dual and quad relay models, a DPDT relay option and an FMEDA option on some configurations. The string SPA2/TPRG/2PRG/U/-AO [DIN] is the dual-relay temperature model with the analog output option. If SIL-rated functionality is required, check the STA safety trip alarm instead.
Confirm the input type first. The SPA2 family has different model strings for current and voltage inputs and for temperature and resistance inputs, so the input field of the part number must match the sensor or transmitter you are wiring.
Check the relay contact rating against the load you intend to switch. The relays are rated for the values shown in the specifications table; for inductive loads such as contactor coils or solenoids, use an interposing relay or suppression as your plant standard requires.
Decide whether the unit is a replacement or a new installation. For replacements, compare the supply range, relay count, analog output option and housing against the nameplate of the unit being removed. Send the old nameplate details together with your RFQ and we will compare them with the datasheet ordering table.
Installation and commissioning
Mount the SPA2/TPRG/2PRG/U/-AO [DIN] on its rail or bracket in a clean, ventilated panel, away from heavy switchgear and power cables where possible. Leave room for the front-panel buttons and for the viewing angle of the display.
Wire the supply, input and relay terminals according to the terminal drawing in the manufacturer manual. Use the wire size range given in that manual and tighten terminals to the stated torque. Keep the input cable separate from relay and power cabling and use shielded cable on long sensor or signal runs.
On power-up, set the input type and range, assign each relay to a high or low trip with its trip point and dead band, choose normally open or closed and failsafe behaviour, and set any trip delay. Test every relay by moving the input signal through the trip point, and record the final settings and password in your commissioning file.
Maintenance and spares
Alarm trips are low-maintenance devices, but a safety or shutdown duty deserves a documented proof-test. Plan a periodic functional check of each relay by simulating the input at and beyond the trip points, and verify that the downstream shutdown or alarm action really occurs.
Check terminals for tightness and corrosion during planned outages, keep the front window and vents free of dust, and record the as-found and as-left settings. If a unit is replaced, load the saved configuration or re-enter the recorded settings and repeat the functional test before returning the loop to service.
Related products and ordering notes
Related models in the same alarm trip range include the SPA2IS (intrinsically safe field connections) and the HART-input SPA. The Intelligent PC Configuration Software can be downloaded from the manufacturer website.
Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Frequently asked questions about SPA2/TPRG/2PRG/U/-AO [DIN]
- What does the SPA2/TPRG/2PRG/U/-AO [DIN] do? It monitors a temperature or resistance input and switches two programmable SPDT relays at user-set high or low limits.
- What power does the SPA2/TPRG/2PRG/U/-AO [DIN] need? The universal option accepts 21.6 to 375 Vdc or 90 to 260 Vac.
- What does -AO mean on the SPA2/TPRG/2PRG/U/-AO [DIN]? It adds an isolated, linearised analog output scalable for 0 to 20 mA or 0 to 10 V.
- What is the trip response time of the SPA2/TPRG/2PRG/U/-AO [DIN]? The datasheet states 256 ms maximum, measured from input step to alarm state change.
- How do I order the SPA2/TPRG/2PRG/U/-AO [DIN]? Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.
Documents and quotation
The manufacturer datasheet for the SPA2 family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.
To request a quotation, send an RFQ that includes the part number SPA2/TPRG/2PRG/U/-AO [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.
Datasheets & Documents
- Datasheet SPA2 Programmable Temperature Limit Alarm Trip Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.
Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.
Moore Industries company profile
| Founded | 1968, North Hills, California, USA, by Leonard W. Moore |
|---|---|
| Headquarters | North Hills, California, since 1974 |
| Ownership | Privately owned (Moore Industries-International, Inc.) |
| First product | SCT signal converter |
| Product families | Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA) |
Milestones
- 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
- 1974: The company moves into its North Hills headquarters.
- 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.
Moore Industries product families on this page
The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:
- Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
- Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
- Signal isolators, repeaters and converters: the SIX
- PID controllers and backup stations: the 535 in 1/4 DIN format
Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.
Where Moore Industries instruments are used
These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.
Moore Industries products we list
Ordering Moore Industries instruments: what we need
Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.
Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.
Browse Moore Industries products by category: Temperature Instrumentation, Controllers & Data Acquisition, Isolator & Barrier.
FAQ
Questions about the SPA2/TPRG/2PRG/U/-AO [DIN] Limit Alarm Trip
Answers from our engineering team on installation, compatibility and integration.
01What does the SPA2/TPRG/2PRG/U/-AO [DIN] do?
It monitors a temperature or resistance input and switches two programmable SPDT relays at user-set high or low limits.
02What power does the SPA2/TPRG/2PRG/U/-AO [DIN] need?
The universal option accepts 21.6 to 375 Vdc or 90 to 260 Vac.
03What does -AO mean on the SPA2/TPRG/2PRG/U/-AO [DIN]?
It adds an isolated, linearised analog output scalable for 0 to 20 mA or 0 to 10 V.
04What is the trip response time of the SPA2/TPRG/2PRG/U/-AO [DIN]?
The datasheet states 256 ms maximum, measured from input step to alarm state change.
05How do I order the SPA2/TPRG/2PRG/U/-AO [DIN]?
Send an RFQ with the part number, quantity and delivery location in Oman or the GCC.