STA/HLPRG/3PRG/U/-AO [DIN] Current/Voltage Safety Trip

Description

Moore STA/HLPRG/3PRG/U/-AO [DIN] overview

The Moore STA/HLPRG/3PRG/U/-AO [DIN] is the current and voltage input version of the Moore Industries STA safety trip alarm. It watches a signal from a process transmitter and acts on it with two process alarms and one input or instrument fault alarm.

The manufacturer states that the STA is certified by exida to IEC 61508:2010 for systematic integrity up to SIL 3 and random integrity up to SIL 2. The HLPRG input model also provides 24 Vdc transmitter excitation, so a two-wire transmitter can be powered directly from the trip alarm without a separate supply.

The unit has a metal RFI and EMI resistant DIN-rail housing and a backlit alphanumeric display.

The part number STA/HLPRG/3PRG/U/-AO [DIN] follows the ordering pattern of the manufacturer datasheet, which lists the fields in this order: unit, input, output, power, options and housing (Unit / Input / Output / Power / Options [Housing]). The string written as STA/HLPRG/3PRG/U/-AO [DIN] is the model example printed in that datasheet, so it describes one complete configuration. If your plant needs a different input, output, supply, option or housing, send the configuration with your RFQ and it will be checked against the ordering table.

  • STA: SIL 2 and SIL 3 capable programmable safety trip alarm
  • HLPRG: programmable current (0 to 50 mA) and voltage (0 to 11 V) input
  • 3PRG: two process relays and one fault relay
  • U: universal power input, 21.6 to 375 Vdc or 90 to 260 Vac
  • -AO: isolated analog output option
  • [DIN]: DIN-style housing for 35 mm Top Hat rail

Key features of the Moore Industries STA/HLPRG/3PRG/U/-AO [DIN]

  • exida certified IEC 61508:2010; SIL 3 systematic, SIL 2 random integrity.
  • Built-in 24 Vdc transmitter excitation on the HLPRG input model, regulated, 24 mA.
  • Current input 0 to 50 mA (4 mA minimum span) and voltage input 0 to 11 V (1 V minimum span).
  • Input accuracy and alarm repeatability of 2 microamps (0.01% of 20 mA span) for current and 1 mV for voltage.
  • Two process relays and a failsafe fault relay, SPDT contacts.
  • Pushbutton setup with password protection or PC software setup.
  • Alarm trip delay programmable from 0 to 120 seconds.
  • Optional isolated and linearised analog output.

Technical specifications for STA/HLPRG/3PRG/U/-AO [DIN]

Parameter Value
Model string Moore STA/HLPRG/3PRG/U/-AO [DIN]
Current input range 0 to 50 mA, minimum span 4 mA
Voltage input range 0 to 11 V, minimum span 1 V
Input accuracy and alarm repeatability Current 2 microamps (0.01% of 20 mA span); voltage 1 mV (0.01% of maximum span)
Input impedance Current 20 ohms; voltage 1 Mohm
Input over-range protection Current plus or minus 100 mA maximum; voltage plus or minus 30 Vdc maximum
Transmitter supply 24 Vdc, plus or minus 10%, 24 mA, regulated
Trip response time 256 ms maximum
Alarm trip delay 0 to 120 seconds programmable
Relays Two process relays and one fault relay, SPDT, 3 A at 250 Vac 50/60 Hz or 3 A at 30 Vdc, non-inductive
Analog output (-AO) Current 0 to 21.6 mA or voltage -0.2 to 10.5 V; accuracy plus or minus 0.01% of maximum span
Power supply Universal 21.6 to 375 Vdc or 90 to 260 Vac; 5 W maximum
Isolation 500 Vrms between case, input, output and power
Dielectric strength 1966 Vdc for 2 seconds
Operating temperature -40 to +85 degrees C
Weight 513 g to 564 g

The values above come from the manufacturer datasheet for the STA family. Specifications can differ by input type and option, so read the matching page of the datasheet before finalising a purchase specification and keep the complete model string on your purchase documents. Where a value is not listed here it was not stated clearly enough in the datasheet to repeat.

Typical applications of the STA/HLPRG/3PRG/U/-AO [DIN] in Oman and the GCC

With the transmitter excitation built in, this model suits pressure, level or flow transmitters that feed a high or low shutdown relay, for example a high-high level trip on a separator or a low-low pressure trip on a lube oil header.

In oil and gas facilities across Oman and the GCC, a programmable alarm trip such as the STA/HLPRG/3PRG/U/-AO [DIN] is used as a stand-alone high or low limit device on temperature, pressure, level and flow signals. It can drive a shutdown relay, a horn or beacon, or a lamp on a local annunciator without loading the main control system.

Power utilities and desalination and water plants use alarm trips to protect motors, pumps and heat exchangers: for example a winding or bearing temperature limit, a tank level limit, or a discharge pressure limit that must act even when the DCS is offline. Manufacturing and process plants use the same idea for batch limits, furnace over-temperature cut-outs and dosing interlocks.

Because the STA/HLPRG/3PRG/U/-AO [DIN] sets up from its front panel or from PC software, one unit stocked in the store room can cover many different duties, which is helpful for remote sites where spare lead times matter.

Selection and compatibility notes for STA/HLPRG/3PRG/U/-AO [DIN]

Use this HLPRG string when the signal is mA or volts. For RTD, thermocouple, ohm or millivolt sources, the TPRG model is the correct family member. Safety use needs a documented SIL assessment by a competent practitioner; the manufacturer offers FMEDA data on request.

Confirm the input type first. The STA family has different model strings for current and voltage inputs and for temperature and resistance inputs, so the input field of the part number must match the sensor or transmitter you are wiring.

Check the relay contact rating against the load you intend to switch. The relays are rated for the values shown in the specifications table; for inductive loads such as contactor coils or solenoids, use an interposing relay or suppression as your plant standard requires.

Decide whether the unit is a replacement or a new installation. For replacements, compare the supply range, relay count, analog output option and housing against the nameplate of the unit being removed. Send the old nameplate details together with your RFQ and we will compare them with the datasheet ordering table.

Installation and commissioning

Mount the STA/HLPRG/3PRG/U/-AO [DIN] on its rail or bracket in a clean, ventilated panel, away from heavy switchgear and power cables where possible. Leave room for the front-panel buttons and for the viewing angle of the display.

Wire the supply, input and relay terminals according to the terminal drawing in the manufacturer manual. Use the wire size range given in that manual and tighten terminals to the stated torque. Keep the input cable separate from relay and power cabling and use shielded cable on long sensor or signal runs.

On power-up, set the input type and range, assign each relay to a high or low trip with its trip point and dead band, choose normally open or closed and failsafe behaviour, and set any trip delay. Test every relay by moving the input signal through the trip point, and record the final settings and password in your commissioning file.

Maintenance and spares

Alarm trips are low-maintenance devices, but a safety or shutdown duty deserves a documented proof-test. Plan a periodic functional check of each relay by simulating the input at and beyond the trip points, and verify that the downstream shutdown or alarm action really occurs.

Check terminals for tightness and corrosion during planned outages, keep the front window and vents free of dust, and record the as-found and as-left settings. If a unit is replaced, load the saved configuration or re-enter the recorded settings and repeat the functional test before returning the loop to service.

Related products and ordering notes

The STA datasheet lists the FMEDA report (700-702-32), the Intelligent PC Configuration Software (750-75E05-01), the serial configuration cable (803-053-26) and a fuse-protected non-isolated USB cable (804-030-26). The temperature-input version is STA/TPRG/3PRG/U/-AO [DIN].

Unit and accessory part numbers such as those named above are separate line items. Please list each one with its quantity so that the quotation covers the complete package. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Frequently asked questions about STA/HLPRG/3PRG/U/-AO [DIN]

  • What input does the STA/HLPRG/3PRG/U/-AO [DIN] accept? It accepts a current from 0 to 50 mA (minimum span 4 mA) or a voltage from 0 to 11 V (minimum span 1 V).
  • Can the STA/HLPRG/3PRG/U/-AO [DIN] power a two-wire transmitter? Yes, the datasheet says the HLPRG input model includes 24 Vdc transmitter excitation, regulated at 24 mA.
  • What are the relay ratings on the STA/HLPRG/3PRG/U/-AO [DIN]? The relays are SPDT rated 3 A at 250 Vac 50/60 Hz or 3 A at 30 Vdc, non-inductive, with two process relays and one fault relay.
  • Is the STA/HLPRG/3PRG/U/-AO [DIN] safety rated? The STA datasheet states exida certification to IEC 61508:2010, with systematic integrity to SIL 3 and random integrity to SIL 2.
  • How do I request a quote for the STA/HLPRG/3PRG/U/-AO [DIN]? Send an RFQ listing the part number, quantity and delivery location in Oman or the GCC.

Documents and quotation

The manufacturer datasheet for the STA family is available from us on request and a copy is attached to this page. It contains the full ordering table, specifications and dimension drawings, and we suggest reading it before you decide on the final configuration.

To request a quotation, send an RFQ that includes the part number STA/HLPRG/3PRG/U/-AO [DIN], the quantity, the delivery location in Oman or the GCC and any special requirement such as certification documents or a required delivery date. Our team will confirm availability and lead time and reply with a written offer.

Other Models in the STA Range

Seven Star LLC supplies models from the STA range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
STA/TPRG/3PRG/U/-AO [DIN] Safety Trip AlarmIsolator & BarrierView details
STA/HLPRG/3PRG/U/-AO [DIN] Current/Voltage Safety TripIsolator & BarrierYou are viewing this model
Datasheets & Documents
  • PDF Datasheet STA SIL 2/3 Capable Current/Voltage Safety Trip Alarm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Moore Industries is an American manufacturer of signal interface instruments, founded in 1968 by engineer Leonard W. Moore in North Hills, California. Its first product was the SCT signal converter, built in a friend's workshop. The company has been at its North Hills headquarters since 1974 and still designs and builds its products there, known for rugged aluminium housings.

Seven Star LLC, an independent supplier in Oman, lists Moore Industries temperature transmitters, limit alarm trips, isolators and a PID backup controller, and sources units and replacements by full model number.

Moore Industries company profile

Founded 1968, North Hills, California, USA, by Leonard W. Moore
Headquarters North Hills, California, since 1974
Ownership Privately owned (Moore Industries-International, Inc.)
First product SCT signal converter
Product families Signal isolators and converters (ECT, SCT), temperature transmitters (TRY, THZ), alarm trip units (SPA), miniMOORE multichannel signal conditioners, HART interfaces, SIL-rated safety logic solvers (STA)

Milestones

  • 1968: Leonard W. Moore founds the company and builds the first SCT signal converter.
  • 1974: The company moves into its North Hills headquarters.
  • 2009: miniMOORE wins a Control Engineering Engineers' Choice Award.

Moore Industries product families on this page

The manufacturer's catalog is arranged by function, and many of the items listed here map onto it directly:

  • Temperature transmitters: the TRX, and the STZ functional safety dual input smart HART transmitter
  • Alarm trips: the SPA2 programmable limit alarm trip, including an SPA2 with HLPRG input and four relay outputs
  • Signal isolators, repeaters and converters: the SIX
  • PID controllers and backup stations: the 535 in 1/4 DIN format

Other catalog groups include temperature assemblies and sensors, I/P and P/I converters, remote I/O, HART gateways and interfaces, indicators, and fieldbus device couplers.

Where Moore Industries instruments are used

These are control room and marshalling cabinet devices, plus field-mounted transmitters. Typical jobs are isolating a 4-20 mA loop between two systems, converting a thermocouple or RTD signal for a DCS input, adding an independent high or low trip next to the control system, and keeping a control loop running on a backup station when the main controller is out of service. Process plants in oil and gas, chemicals and power across the GCC use them for exactly these tasks.

Moore Industries products we list

Family Examples
Controllers & Data Acquisition Moore 535-21120BD000 | Industrial PID Ba…, SPA2 Programmable Limit Alarm Trip, Moore-SPA2HL Associated IS Programmable…
Isolator & Barrier HIM Smart HART Loop Interface and Monitor, SIX Signal Isolator, SLA SIL 2/3 Safety Logic Solver and Alarm
Temperature Instrumentation STZ Functional Safety Dual Input Smart H…, TRX Temperature Transmitter
Industrial Communications HES HART to Ethernet Gateway
Valve Positioners IPT2 Current-to-Pressure I/P Transmitter

Ordering Moore Industries instruments: what we need

Moore Industries model numbers are built from fields separated by slashes: unit, input, output, power and options, followed by the housing code in brackets. Every field matters. Send the complete string from the label, the serial number, and for programmable units the input type and range you want set. State any hazardous area or functional safety requirement, because approved versions are ordered with their own option codes.

Facts checked against trade press obituaries of Leonard W. Moore (Control Engineering, Control Global), October 2026.

FAQ

Questions about the STA/HLPRG/3PRG/U/-AO [DIN] Current/Voltage Safety

Answers from our engineering team on installation, compatibility and integration.

01What input does the STA/HLPRG/3PRG/U/-AO [DIN] accept?
It accepts a current from 0 to 50 mA (minimum span 4 mA) or a voltage from 0 to 11 V (minimum span 1 V).
02Can the STA/HLPRG/3PRG/U/-AO [DIN] power a two-wire transmitter?
Yes, the datasheet says the HLPRG input model includes 24 Vdc transmitter excitation, regulated at 24 mA.
03What are the relay ratings on the STA/HLPRG/3PRG/U/-AO [DIN]?
The relays are SPDT rated 3 A at 250 Vac 50/60 Hz or 3 A at 30 Vdc, non-inductive, with two process relays and one fault relay.
04Is the STA/HLPRG/3PRG/U/-AO [DIN] safety rated?
The STA datasheet states exida certification to IEC 61508:2010, with systematic integrity to SIL 3 and random integrity to SIL 2.
05How do I request a quote for the STA/HLPRG/3PRG/U/-AO [DIN]?
Send an RFQ listing the part number, quantity and delivery location in Oman or the GCC.